Seismicity, Buildings’ Seismic Vulnerability, and People’s Risk Awareness and Preparedness in General Santos City, Philippines

2016 ◽  
Author(s):  
Sven Bienert ◽  
Georgia Warren-Myers ◽  
Jens Hirsch

2019 ◽  
Vol 3 (Special Issue on First SACEE'19) ◽  
pp. 199-206
Author(s):  
Bertha Olmos ◽  
José Jara ◽  
José Luis Fabián

This paper investigates the effects of the nonlinear behaviour of isolation pads on the seismic capacity of bridges to identify the parameters of base isolation systems that can be used to improve seismic performance of bridges. A parametric study was conducted by designing a set of bridges for three different soil types and varying the number of spans, span lengths, and pier heights. The seismic responses (acceleration, displacement and pier seismic forces) were evaluated for two structural models. The first model corresponded to the bridges supported on elastomeric bearings with linear elastic behaviour and the second model simulated a base isolated bridge that accounts for the nonlinear behaviour of the system. The seismic demand was represented with a group of twelve real accelerograms recorded on the subduction zone on the Pacific Coast of Mexico. The nonlinear responses under different damage scenarios for the bridges included in the presented study were estimated. These results allow determining the seismic capacity of the bridges with and without base isolation. Results show clearly the importance of considering the nonlinear behaviour on the seismic performance of bridges and the influence of base isolation on the seismic vulnerability of medium size bridges.


2019 ◽  
Vol 3 (Special Issue on First SACEE'19) ◽  
pp. 207-2016
Author(s):  
Guillermo Martinez ◽  
David Castillo ◽  
José Jara ◽  
Bertha Olmos

This paper presents a first approximation of the seismic vulnerability of a sixteenth century building which is part of the historical center of Morelia, Mexico. The city was declared World Heritage by United Nations Educational, Scientific and Cultural Organization in 1991. The modeling and analysis of the building was carried out using a three-dimensional elastic tetrahedral finite elements model which was subjected to probabilistic seismic demands with recurrences of 500 yrs and 1000 yrs in addition to real seismic records. The model was able to correctly identify cracking pattern in different parts of the temple due to gravitational forces. High seismic vulnerability of the arched window and the walls of the middle part of the bell tower of the temple was indicated by the seismic analysis of the model.


Author(s):  
Martina Caruso ◽  
Rui Pinho ◽  
Federica Bianchi ◽  
Francesco Cavalieri ◽  
Maria Teresa Lemmo

AbstractA life cycle framework for a new integrated classification system for buildings and the identification of renovation strategies that lead to an optimal balance between reduction of seismic vulnerability and increase of energy efficiency, considering both economic losses and environmental impacts, is discussed through a parametric application to an exemplificative case-study building. Such framework accounts for the economic and environmental contributions of initial construction, operational energy consumption, earthquake-induced damage repair activities, retrofitting interventions, and demolition. One-off and annual monetary expenses and environmental impacts through the building life cycle are suggested as meaningful performance metrics to develop an integrated classification system for buildings and to identify the optimal renovation strategy leading to a combined reduction of economic and environmental impacts, depending on the climatic conditions and the seismic hazard at the site of interest. The illustrative application of the framework to an existing school building is then carried out, investigating alternative retrofitting solutions, including either sole structural retrofitting options or sole energy refurbishments, as well as integrated strategies that target both objectives, with a view to demonstrate its practicality and to explore its ensuing results. The influence of seismic hazard and climatic conditions is quantitatively investigated, by assuming the building to be located into different geographic locations.


2021 ◽  
Vol 1763 (1) ◽  
pp. 012015
Author(s):  
M Rusydi ◽  
M B Cyio ◽  
Rahmawati ◽  
Ramlan

Author(s):  
A. Sandoli ◽  
G. P. Lignola ◽  
B. Calderoni ◽  
A. Prota

AbstractA hybrid seismic fragility model for territorial-scale seismic vulnerability assessment of masonry buildings is developed and presented in this paper. The method combines expert-judgment and mechanical approaches to derive typological fragility curves for Italian residential masonry building stock. The first classifies Italian masonry buildings in five different typological classes as function of age of construction, structural typology, and seismic behaviour and damaging of buildings observed following the most severe earthquakes occurred in Italy. The second, based on numerical analyses results conducted on building prototypes, provides all the parameters necessary for developing fragility functions. Peak-Ground Acceleration (PGA) at Ultimate Limit State attainable by each building’s class has been chosen as an Intensity Measure to represent fragility curves: three types of curve have been developed, each referred to mean, maximum and minimum value of PGAs defined for each building class. To represent the expected damage scenario for increasing earthquake intensities, a correlation between PGAs and Mercalli-Cancani-Sieber macroseismic intensity scale has been used and the corresponding fragility curves developed. Results show that the proposed building’s classes are representative of the Italian masonry building stock and that fragility curves are effective for predicting both seismic vulnerability and expected damage scenarios for seismic-prone areas. Finally, the fragility curves have been compared with empirical curves obtained through a macroseismic approach on Italian masonry buildings available in literature, underlining the differences between the methods.


Fire ◽  
2021 ◽  
Vol 4 (1) ◽  
pp. 11
Author(s):  
Charlotte Fafet ◽  
Erinë Mulolli Zajmi

Fires are among the most frequently recurring hazards affecting museums and cultural heritage sites. The fires of the National Museum of Brazil in 2018 and of Notre Dame de Paris in 2019 showed that the consequences of such events can be heavy and lead to irreversible heritage losses. In Kosovo, few studies were made about the risks that can affect cultural heritage sites. A project led by the NGO Kosovo Foundation for Cultural Heritage without Borders (CHwB Kosova) in 2018 explored the most prevalent risks for the cultural heritage sites of the country and highlighted fire as a predominant risk in Kosovo. In order to better understand it, vulnerability assessments were conducted in several museums in Kosovo. Data were collected through field visits in the different museums, in which interviews with staff members as well as observations were conducted. The aim of this paper is to present the main results of the fire vulnerability assessments conducted in Kosovo’s museums in 2018. An important aspect of this project is the approach to collect information in data-scarce environments. It is believed that the questionnaires used to lead interviews with museums’ staff members could help other practitioners to collect data in such contexts and evaluate more easily the risk of fire for the museums and their collections. In the context of Kosovo, one of the main findings is the identification and prioritisation of measures to ensure better protection of Kosovar museums. Structural mitigation measures such as alarm and fire suppression systems are not the only elements necessary to improve the resilience of Kosovar museums to fire. Indeed, the promotion of risk awareness, the training of staff members and the realisation of crisis simulation exercises are just as important in order to prevent and detect a fire, and above all, to respond quickly and accurately if a fire occurs.


Sign in / Sign up

Export Citation Format

Share Document