scholarly journals Enhanced Removal Efficiency of Arsenic and Copper from Aqueous Solution Using Activated Acorus calamus Based Adsorbent

Author(s):  
Anita Chand ◽  
Prem Chand ◽  
Gopal Gautam Khatri ◽  
Dasu Ram Paudel
2019 ◽  
Vol 70 (5) ◽  
pp. 1507-1512
Author(s):  
Baker M. Abod ◽  
Ramy Mohamed Jebir Al-Alawy ◽  
Firas Hashim Kamar ◽  
Gheorghe Nechifor

The aim of this study is to use the dry fibers of date palm as low-cost biosorbent for the removal of Cd(II), and Ni(II) ions from aqueous solution by fluidized bed column. The effects of many operating conditions such as superficial velocity, static bed height, and initial concentration on the removal efficiency of metal ions were investigated. FTIR analyses clarified that hydroxyl, amine and carboxyl groups could be very effective for bio-sorption of these heavy metal ions. SEM images showed that dry fibers of date palm have a high porosity and that metal ions can be trapped and sorbed into pores. The results show that a bed height of 6 cm, velocity of 1.1Umf and initial concentration for each heavy metal ions of 50 mg/L are most feasible and give high removal efficiency. The fluidized bed reactor was modeled using ideal plug flow and this model was solved numerically by utilizing the MATLAB software for fitting the measured breakthrough results. The breakthrough curves for metal ions gave the order of bio-sorption capacity as follow: Cd(II)]Ni(II).


Author(s):  
Haiyan Song ◽  
Wei Liu ◽  
Fansheng Meng ◽  
Qi Yang ◽  
Niandong Guo

Nanoscale zero-valent iron (nZVI) has attracted considerable attention for its potential to sequestrate and immobilize heavy metals such as Cr(VI) from an aqueous solution. However, nZVI can be easily oxidized and agglomerate, which strongly affects the removal efficiency. In this study, graphene-based nZVI (nZVI/rGO) composites coupled with ultrasonic (US) pretreatment were studied to solve the above problems and conduct the experiments of Cr(VI) removal from an aqueous solution. SEM-EDS, BET, XRD, and XPS were performed to analyze the morphology and structures of the composites. The findings showed that the removal efficiency of Cr(VI) in 30 min was increased from 45.84% on nZVI to 78.01% on nZVI/rGO and the removal process performed coupled with ultrasonic pretreatment could greatly shorten the reaction time to 15 min. Influencing factors such as the initial pH, temperature, initial Cr(VI) concentration, and co-existing anions were studied. The results showed that the initial pH was a principal factor. The presence of HPO42−, NO3−, and Cl− had a strong inhibitory effect on this process, while the presence of SO42− promoted the reactivity of nZVI/rGO. Combined with the above results, the process of Cr(VI) removal in US-nZVI/rGO system consisted of two phases: (1) The initial stage is dominated by solution reaction. Cr(VI) was reduced in the solution by Fe2+ caused by ultrasonic cavitation. (2) In the following processes, adsorption, reduction, and coprecipitation coexisted. The addition of rGO enhanced electron transportability weakened the influence of passivation layers and improved the dispersion of nZVI particles. Ultrasonic cavitation caused pores and corrosion at the passivation layers and fresh Fe0 core was exposed, which improved the reactivity of the composites.


2021 ◽  
pp. 116774
Author(s):  
Fataneh Vasheghani Farahani ◽  
Mohammad Hassan Amini ◽  
Seyed Hamid Ahmadi ◽  
Seyed Amirabbas Zakaria

1996 ◽  
Vol 34 (9) ◽  
pp. 101-108 ◽  
Author(s):  
M. Kuroda ◽  
T. Watanabe ◽  
Y. Umedu

Application of a bio-electro reactor for treatment of various kinds of polluted water was investigated experimentally. Aqueous solution of nitrate, ammonium and/or organic matter were used as synthetic polluted water. Denitrification of the nitrate polluted water without organic matter proceeded effectively by utilizing hydrogen gas produced by electrolysis of water in the reactor. The bio-electro reactor was also available for the treatment of nitrate polluted water containing organic matter when the C/N concentration ratio was up to 1.0 under the condition of 100 mA of applied electric current. The nitrate removal efficiency from nitrate polluted water containing acetate at C/N=1.0 was more than 90% at 5 hours of HRT and 80% even at 2.8 h HRT. For the treatment of ammonium polluted water, nitrification and denitrification proceeded simultaneously in a bio-electro reactor where nitrifying and denitrifying microorganisms were immobilized on the electrodes. The results obtained in this study suggested that the bio-electro reactor system was capable to application for oxidation and reduction treatments of the nitrate and ammonium polluted water.


2017 ◽  
Vol 76 (6) ◽  
pp. 1466-1473 ◽  
Author(s):  
M. H. Salmani ◽  
M. Mokhtari ◽  
Z. Raeisi ◽  
M. H. Ehrampoush ◽  
H. A. Sadeghian

Wastewater containing pharmaceutical residual components must be treated before being discharged to the environment. This study was conducted to investigate the efficiency of tungsten-carbon nanocomposite in diclofenac removal using design of experiment (DOE). The 27 batch adsorption experiments were done by choosing three effective parameters (pH, adsorbent dose, and initial concentration) at three levels. The nanocomposite was prepared by tungsten oxide and activated carbon powder in a ratio of 1 to 4 mass. The remaining concentration of diclofenac was measured by a spectrometer with adding reagents of 2, 2′-bipyridine, and ferric chloride. Analysis of variance (ANOVA) was applied to determine the main and interaction effects. The equilibrium time for removal process was determined as 30 min. It was observed that the pH had the lowest influence on the removal efficiency of diclofenac. Nanocomposite gave a high removal at low concentration of 5.0 mg/L. The maximum removal for an initial concentration of 5.0 mg/L was 88.0% at contact time of 30 min. The results of ANOVA showed that adsorbent mass was among the most effective variables. Using DOE as an efficient method revealed that tungsten-carbon nanocomposite has high efficiency in the removal of residual diclofenac from the aqueous solution.


Desalination ◽  
2010 ◽  
Vol 255 (1-3) ◽  
pp. 44-51 ◽  
Author(s):  
Krishna Biswas ◽  
Kaushik Gupta ◽  
Arijit Goswami ◽  
Uday Chand Ghosh

2020 ◽  
Author(s):  
Zeinab Ghorbani

This study aimed to investigate the efficiency of the electro-persulfate process in removing acid blue 25 from aqueous solution. In order to optimize the parameters, the OFAT method was used, and the effect of three main parameters, including pH, sodium persulfate salt concentration, and current intensity was investigated. According to the results, the optimal removal efficiency of 94% in 60 minutes was obtained under conditions of pH=5, the initial concentration of sodium persulfate=250 mg / L, and the current=500 mA. According to the results of this study, the electro-persulfate process sulfate process can be an efficient process for dye removal from industrial effluents.


2019 ◽  
Vol 84 (7) ◽  
pp. 713-727 ◽  
Author(s):  
Jiteng Wan ◽  
Chunji Jin ◽  
Banghai Liu ◽  
Zonglian She ◽  
Mengchun Gao ◽  
...  

Even in a trace amounts, the presence of antibiotics in aqueous solution is getting more and more attention. Accordingly, appropriate technologies are needed to efficiently remove these compounds from aqueous environments. In this study, we have examined the electrochemical oxidation (EO) of sulfamethoxazole (SMX) on a Co modified PbO2 electrode. The process of EO of SMX in aqueous solution followed the pseudo-first-order kinetics, and the removal efficiency of SMX reached the maximum value of 95.1 % within 60 min. The effects of major factors on SMX oxidation kinetics were studied in detail by single-factor experiments, namely current density (1?20 mA cm-2), solution pH value (2?10), initial concentration of SMX (10?500 mg L-1) and concentration of electrolytes (0.05?0.4 mol L-1). An artificial neural network (ANN) model was used to simulate this EO process. Based on the obtained model, particle swarm optimization (PSO) was used to optimize the operating parameters. The maximum removal efficiency of SMX was obtained at the optimized conditions (e.g., current density of 12.37 mA cm-2, initial pH value of 4.78, initial SMX concentration of 74.45 mg L-1, electrolyte concentration of 0.24 mol L-1 and electrolysis time of 51.49 min). The validation results indicated that this method can ideally be used to optimize the related parameters and predict the anticipated results with acceptable accuracy.


Sign in / Sign up

Export Citation Format

Share Document