Technique of aerosol generation of antibacterial medicine cefazolin

Keyword(s):  
2020 ◽  
pp. bjophthalmol-2020-317214
Author(s):  
Hasan Naveed ◽  
Fong May Chew ◽  
Hanbin Lee ◽  
Edward Hughes ◽  
Mayank A Nanavaty

PurposeTo assess whether pars plana vitrectomy (PPV) is an aerosol-generating procedure (AGP) in an ex vivo experimental model.MethodsIn this ex vivo study on 10 porcine eyes, optical particle counter was used to measure particles ≤10 μm using cumulative mode in the six in-built channels: 0.3 μm, 0.5 μm, 1 μm, 2.5 μm, 5 μm and 10 μm aerosols during PPV. Two parts of the study were as follows: (1) to assess the pre-experimental baseline aerosol count in the theatre environment where there are dynamic changes in temperature and humidity and (2) to measure aerosol generation with 23-gauge and 25-gauge set-up. For each porcine eye, five measurements were taken for each consecutive step in the experiment including pre-PPV, during PPV, fluid–air exchange (FAX) and venting using a flute with 23-gauge set-up and a chimney with 25-gauge set-up. Therefore, a total of 200 measurements were recorded.ResultsWith 23-gauge and 25-gauge PPV, there was no significant difference in aerosol generation in all six channels comparing pre-PPV versus PPV or pre-PPV versus FAX. Venting using flute with 23-gauge PPV showed significant reduction of aerosol ≤1 μm. Air venting using chimney with 25-gauge set-up showed no significant difference in aerosol of ≤1 μm. For cumulative aerosol counts of all particles measuring ≤5 μm, compared with pre-PPV, PPV or FAX, flute venting in 23-gauge set-up showed significant reduction unlike the same comparison for chimney venting in 25-gauge set-up.ConclusionPPV and its associate steps do not generate aerosols ≤10 μm with 23-gauge and 25-gauge set-ups.


2020 ◽  
Vol 4 ◽  
pp. 239784732097975
Author(s):  
Stéphanie Boué ◽  
Didier Goedertier ◽  
Julia Hoeng ◽  
Anita Iskandar ◽  
Arkadiusz K Kuczaj ◽  
...  

E-vapor products (EVP) have become popular alternatives for cigarette smokers who would otherwise continue to smoke. EVP research is challenging and complex, mostly because of the numerous and rapidly evolving technologies and designs as well as the multiplicity of e-liquid flavors and solvents available on the market. There is an urgent need to standardize all stages of EVP assessment, from the production of a reference product to e-vapor generation methods and from physicochemical characterization methods to nonclinical and clinical exposure studies. The objective of this review is to provide a detailed description of selected experimental setups and methods for EVP aerosol generation and collection and exposure systems for their in vitro and in vivo assessment. The focus is on the specificities of the product that constitute challenges and require development of ad hoc assessment frameworks, equipment, and methods. In so doing, this review aims to support further studies, objective evaluation, comparison, and verification of existing evidence, and, ultimately, formulation of standardized methods for testing EVPs.


Author(s):  
Camila Quartim de Moraes Bruna ◽  
Caroline Lopes Ciofi-Silva ◽  
Anderson Vicente de Paula ◽  
Lucy Santos Villas Boas ◽  
Noely Evangelista Ferreira ◽  
...  

AbstractAerosolization may occur during reprocessing of medical devices. With the current coronavirus disease 2019 pandemic, it is important to understand the necessity of using respirators in the cleaning area of the sterile processing department. To evaluate the presence of severe acute respiratory syndrome coronavirus (SARS-CoV-2) in the air of the sterile processing department during the reprocessing of contaminated medical devices. Air and surface samples were collected from the sterile processing department of two teaching tertiary hospitals during the reprocessing of respiratory equipment used in patients diagnosed with coronavirus disease 2019 and from intensive care units during treatment of these patients. SARS-CoV-2 was detected only in 1 air sample before the beginning of decontamination process. Viable severe acute respiratory syndrome coronavirus 2 RNA was not detected in any sample collected from around symptomatic patients or in sterile processing department samples. The cleaning of respiratory equipment does not cause aerosolization of SARS-CoV-2. We believe that the use of medical masks is sufficient while reprocessing medical devices during the coronavirus disease 2019 pandemic.


Anaesthesia ◽  
2021 ◽  
Author(s):  
A. J. Shrimpton ◽  
F. K. A. Gregson ◽  
J. M. Brown ◽  
T. M. Cook ◽  
B. R. Bzdek ◽  
...  

2021 ◽  
Vol 5 ◽  
pp. 239784732110222
Author(s):  
David Thorne ◽  
Roman Wieczorek ◽  
Toshiro Fukushima ◽  
Han-Jae Shin ◽  
Robert Leverette ◽  
...  

During a Cooperation Centre for Scientific Research Relative to Tobacco (CORESTA) meeting, the in vitro toxicity testing Sub-Group (IVT SG) met to discuss the evolving field of aerosol exposure research. Given the diversity of exposure parameters and biological endpoints being used, it was considered a high priority to investigate and contextualise the responses obtained. This is particularly driven by the inability to compare between studies on different exposure systems due to user preferences and protocol differences. Twelve global tobacco and contract research companies met to discuss this topic and formulate an aligned approach on how this diverging field of research could be appropriately compared. Something that is becoming increasingly important, especially in the light of more focused regulatory scrutiny. A detailed and comprehensive survey was conducted on over 40 parameters ranging from aerosol generation, dilution and data analysis across eight geographically independent laboratories. The survey results emphasise the diversity of in vitro exposure parameters and methodologies employed across the IVT SG and highlighted pockets of harmonisation. For example, many of the biological protocol parameters are consistent across the Sub-Group. However, variables such as cell type and exposure time remain largely inconsistent. The next steps for this work will be to map parameters and system data against biological findings and investigate whether the observed inconsistencies translate into increased biological variability. The results from the survey provide improved awareness of parameters and nuances, that may be of substantial benefit to scientists in intersecting fields and in the development of harmonised approaches.


2020 ◽  
Vol 231 (6) ◽  
pp. 783
Author(s):  
Indu Kapoor ◽  
Hemanshu Prabhakar ◽  
Charu Mahajan
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document