Single-Phase Voltage-Quadrupler Rectifier Using Only One Dual-Switch Power Module

2012 ◽  
Vol 132 (4) ◽  
pp. 524-525
Author(s):  
Ryozo Itoh ◽  
Kouichi Ishizaka ◽  
Yasuhiko Neba ◽  
Hirokazu Matsumoto ◽  
Takahiro Haraguchi
2016 ◽  
Vol 2016 (4) ◽  
pp. 20-22
Author(s):  
D.K. Makov ◽  
◽  
O.V. Polishchuk ◽  
Keyword(s):  

2015 ◽  
Vol 135 (3) ◽  
pp. 168-180 ◽  
Author(s):  
Ryota Mizutani ◽  
Hirotaka Koizumi ◽  
Kentaro Hirose ◽  
Kazunari Ishibashi

Author(s):  
Luo Xiaohui

This paper proposed a low cost wireless monitoring system based on ZigBee wireless transmission, and designed a new floating voltage sensor which is suitable for the monitoring of medium voltage and high voltage(MV/HV) public equipment. The system used TI-CC2530 as the controller, proposed a new moving average voltage sensing(MAVS) algorithm by reasonable assumptions, and adopted algorithms to perform the theoretical analysis for the single phase and three-phase voltage. At last, the author carried out a practical experiment on the wireless floating voltage sensor under the voltage up to 30kV, the experimental results showed that the proposed low cost wireless sensor can achieve a good voltage monitoring function, and the error is less than 3%.


2019 ◽  
Vol 81 (4) ◽  
Author(s):  
Hari Prasetijo ◽  
Winasis Winasis ◽  
Priswanto Priswanto ◽  
Dadan Hermawan

This study aims to observe the influence of the changing stator dimension on the air gap magnetic flux density (Bg) in the design of a single-phase radial flux permanent magnet generator (RFPMG). The changes in stator dimension were carried out by using three different wire diameters as stator wire, namely, AWG 14 (d = 1.63 mm), AWG 15 (d = 1.45 mm) and AWG 16 (d = 1.29 mm). The dimension of the width of the stator teeth (Wts) was fixed such that a larger stator wire diameter will require a larger stator outside diameter (Dso). By fixing the dimensions of the rotor, permanent magnet, air gap (lg) and stator inner diameter, the magnitude of the magnetic flux density in the air gap (Bg) can be determined. This flux density was used to calculate the phase back electromotive force (Eph). The terminal phase voltage (V∅) was determined after calculating the stator wire impedance (Z) with a constant current of 3.63 A. The study method was conducted by determining the design parameters, calculating the design variables, designing the generator dimensions using AutoCad and determining the magnetic flux density using FEMM simulation.  The results show that the magnetic flux density in the air gap and the phase back emf Eph slightly decrease with increasing stator dimension because of increasing reluctance. However, the voltage drop is more dominant when the stator coil wire diameter is smaller. Thus, a larger diameter of the stator wire would allow terminal phase voltage (V∅) to become slightly larger. With a stator wire diameter of 1.29, 1.45 and 1.63 mm, the impedance values of the stator wire (Z) were 9.52746, 9.23581 and 9.06421 Ω and the terminal phase voltages (V∅) were 220.73, 221.57 and 222.80 V, respectively. Increasing the power capacity (S) in the RFPMG design by increasing the diameter (d) of the stator wire will cause a significant increase in the percentage of the stator maximum current carrying capacity wire but the decrease in stator wire impedance is not significant. Thus, it will reduce the phase terminal voltage (V∅) from its nominal value.


2021 ◽  
Vol 2 (2) ◽  
pp. 44-53
Author(s):  
GENNADY S. MYTSYK ◽  
◽  
ZAW HTET HEIN ◽  

The recent interest of developers of new technology in studying a structural and algorithmic synthesis (SAS) of voltage source inverters (VSI) for solar power plants (SPP) is stemming from a growing need to solve problems in connection with the revealed new possibilities of converting energy flow (from DC to AC) with better energy efficiency by reducing the depth of its pulse modulation. This problem is solved by using more rational structural and algorithmic solutions. It is shown that for SPPs for a capacity of about 1 MW and more, it is more expedient to construct inverters based on the energy flow multichannel conversion principle. Given a limited power capacity of the transistor components, the application of this principle allows the problem to be solved in fact without using an output filter. The output voltage waveform is shaped using the energy flow pulse-amplitude modulation (PAM), and its M parts are summed in the output circuit by out using M winding transfilters (M-TF). The proposed method for carrying out combined SAS of single-phase voltage source inverters with multichannel conversion is considered, which consists in using an N-level single-phase VSI (N-SPVSI) in each of the M channels with the voltage levels optimized in terms of the minimum total harmonic distortion (THD). The resulting voltage of this class of single-phase inverters, designated as MxN-SPVSI, is formed by the corresponding phase shift of the channel voltages followed by summing the channel currents by M-TF. It is shown that the resulting output voltage levels are also close to their values optimized with respect to the minimum of the THD indicator. The results from a comparative analysis of two options — a single-channel 8-level inverter and a four-channel 8-level inverter are given. For the second option, only one intermediate voltage tap in the solar battery is required (instead of seven taps in the first option) along with modern transistor components that are available for practical implementation. In both options, the THD value less than 5% is obtained with almost no need of using an output filter. The presented results provide a certain information and methodological support for system designing of single-phase voltage source inverters as applied to the specific features of solar power plants. Three-phase inverters can be built on the basis of three single-phase inverters with galvanic isolation of the power sources for each phase.


Sign in / Sign up

Export Citation Format

Share Document