scholarly journals Development of the control method of distribution network voltage and reactive power applied with GA•NN

1998 ◽  
Vol 118 (9) ◽  
pp. 998-1005 ◽  
Author(s):  
Hiroyuki Fudo ◽  
Takamu Genji ◽  
Masaru Yukawa ◽  
Seiya Abe ◽  
Masao Shimamoto ◽  
...  
2021 ◽  
Vol 4 (S2) ◽  
Author(s):  
Marika Nakamura ◽  
Shinya Yoshizawa ◽  
Hideo Ishii ◽  
Yasuhiro Hayashi

AbstractAs the number of photovoltaic (PV) power generators connected to the distribution grid increases, applications of on-load tap changers (OLTCs), power conditioning systems, and static reactive power compensators are being considered to mitigate the problem of voltage violation in low voltage distribution systems. The reactive power control by power conditioning systems and static reactive power compensators can mitigate steep voltage fluctuations. However, it creates losses in generation opportunities. On the other hand, OLTCs are installed at the bases of distribution lines and can collectively manage the entire system. However, the conventional voltage control method, i.e., the line drop compensation (LDC) method, is not designed for the case in which a large number of PV systems are installed in the distribution network, which results in voltage violations above the limit of the acceptable range. This study proposes a method to determine the optimal LDC control parameters of the voltage regulator, considering the power factor of PV systems to minimize the magnitude of voltage violations based on the voltage profile analysis of low-voltage (LV) distribution networks. Specifically, during a measurement period of several days, the voltages at some LV consumers and pole transformers were measured, and the optimal parameters were determined by analyzing the collected data. The effectiveness of the proposed method was verified through a numerical simulation study using the actual distribution system model under several scenarios of PV penetration rates. Additionally, the difference in the effectiveness of voltage violation reduction was verified in the case where all the LV consumer’s consumer voltage data measured per minute were used as well as in the case where only the maximum and minimum values of the data within the measurement period were used. The results reveal that the proposed method, which operates within the parameters determined by the voltage analysis of the LV distribution network, is superior to the conventional method. Furthermore, it was found that even if only the maximum and minimum values of the measurement data were used, an effective voltage violation reduction could be expected.


2015 ◽  
Vol 719-720 ◽  
pp. 486-489
Author(s):  
Li Chen

This paper analyses and researches the performance and principle of DSTATCOM in distribution network .Detecting means and control method of DSTATCOM are key point of this paper. The paper determines the detecting means of improved d-q transformation theory of vector control based on instantaneous reactive power and adopts a novel strategy based on the prediction table of double variable. Moreover, the simulation of DSTATCOM is presented with MATLAB. The simulating results prove the DSTATCOM put forward in the paper can realize dynamic reactive power compensation efficiently.


2012 ◽  
Vol 132 (4) ◽  
pp. 359-370 ◽  
Author(s):  
Akira Koide ◽  
Takao Tsuji ◽  
Tsutomu Oyama ◽  
Takuhei Hashiguchi ◽  
Tadahiro Goda ◽  
...  

2014 ◽  
Vol 187 (1) ◽  
pp. 1-15 ◽  
Author(s):  
Akira Koide ◽  
Takao Tsuji ◽  
Tsutomu Oyama ◽  
Takuhei Hashiguchi ◽  
Tadahiro Goda ◽  
...  

Author(s):  
Akram Qashou ◽  
Sufian Yousef ◽  
Abdallah A. Smadi ◽  
Amani A. AlOmari

AbstractThe purpose of this paper is to describe the design of a Hybrid Series Active Power Filter (HSeAPF) system to improve the quality of power on three-phase power distribution grids. The system controls are comprise of Pulse Width Modulation (PWM) based on the Synchronous Reference Frame (SRF) theory, and supported by Phase Locked Loop (PLL) for generating the switching pulses to control a Voltage Source Converter (VSC). The DC link voltage is controlled by Non-Linear Sliding Mode Control (SMC) for faster response and to ensure that it is maintained at a constant value. When this voltage is compared with Proportional Integral (PI), then the improvements made can be shown. The function of HSeAPF control is to eliminate voltage fluctuations, voltage swell/sag, and prevent voltage/current harmonics are produced by both non-linear loads and small inverters connected to the distribution network. A digital Phase Locked Loop that generates frequencies and an oscillating phase-locked output signal controls the voltage. The results from the simulation indicate that the HSeAPF can effectively suppress the dynamic and harmonic reactive power compensation system. Also, the distribution network has a low Total Harmonic Distortion (< 5%), demonstrating that the designed system is efficient, which is an essential requirement when it comes to the IEEE-519 and IEC 61,000–3-6 standards.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3549
Author(s):  
Pham Quoc Khanh ◽  
Viet-Anh Truong ◽  
Ho Pham Huy Anh

The paper proposes a new speed control method to improve control quality and expand the Permanent Magnet Synchronous Motors speed range. The Permanent Magnet Synchronous Motors (PMSM) speed range enlarging is based on the newly proposed power control principle between two voltage sources instead of winding current control as the conventional Field Oriented Control method. The power management between the inverter and PMSM motor allows the Flux-Weakening obstacle to be overcome entirely, leading to a significant extension of the motor speed to a constant power range. Based on motor power control, a new control method is proposed and allows for efficiently reducing current and torque ripple caused by the imbalance between the power supply of the inverter and the power required through the desired stator current. The proposed method permits for not only an enhanced PMSM speed range, but also a robust stability in PMSM speed control. The simulation results have demonstrated the efficiency and stability of the proposed control method.