scholarly journals Smartphone-Based Color Measurement of Tooth Shade Guide in Clinical Lighting Conditions

2021 ◽  
Author(s):  
Agnieszka Radziun ◽  
Rafał Doniec ◽  
Szymon Sieciński ◽  
Natalia Piaseczna ◽  
Katarzyna Mocny-Pachońska ◽  
...  
2018 ◽  
Vol 22 (2) ◽  
pp. 87-92
Author(s):  
Sait Ege Eryürük ◽  
Canan Hekimoğlu ◽  
Elif Tuba Akçin ◽  
Yeliz Çavuşoğlu

SummaryBackground/Aim: The purpose of this study was to evaluate compatibility between visual and digital color measurement methods.Material and Methods: The color measurement components of intact natural maxillary right central incisor and left canine teeth of eighty patients were measured with visually shade guide and, digitally, with digital device. The color matchings were performed for each teeth on labial surfaces divided into three regions: cervical, middle and incisal. Ligthness, MLR (M: means middle hue, L designates greener, R designates redder) and chroma levels were assessed for each tooth on divided regions respectively. Measurements were performed by the same and experinced dentist with healthy eyes. The data were analyzed with Kappa and weighted Kappa coefficient (p< 0.05).Results: The compatibility between visual and digital methods did not exist for MLR and chroma. The compatibility between both methods were determined only for ligthness of maxillary central and canine teeth at all regions of labial surfaces.Conclusions: There was compatibility only for ligthness of intact natural teeth at all regions with both methods.


2017 ◽  
Vol 18 (8) ◽  
pp. 683-687
Author(s):  
Deepak Mehta ◽  
Nishant Gupta ◽  
Rohit M Shetty ◽  
Adarsh N Bhat ◽  
Gopalakrishna Srivatsa ◽  
...  

ABSTRACT Aim The aim of this study is to compare the color space of Vita Lumin shade guide (SG) with the natural teeth of the local population. Materials and methods A total of 100 maxillary central incisors (100 patients) were subjected to color measurement with a spectrocolorimeter. For each tooth, L*, a*, b* values were recorded. All the shade tabs of Vita Lumin SG were analyzed with a spectrocolorimeter to define the color space covered by the Vita Lumin SG. The L*a*b* values of natural teeth were plotted on separate scattered diagrams and compared. Results About two out of three attributes (luminance and blue spectrum) of the local population of Bengaluru displayed a broader range than those available in Vita Lumin SG. Conclusion The local population requires an SG with an extended range, covering a higher luminance spectrum and broader blue spectrum. Clinical significance Esthetic restorations require accurate shade matching with the adjacent natural teeth, SGs being the mean of shade selection and communication should be comparable to the natural teeth. How to cite this article Shetty RM, Bhat AN, Gupta N, Mehta D, Srivatsa G, Singh I. Comparison between Color Spaces of Vita Lumin Shade Guide with Natural Teeth in Bengaluru Population using Spectrocolorimeter: An in vivo Study. J Contemp Dent Pract 2017;18(8):683-687.


2016 ◽  
Vol 17 (1) ◽  
pp. 22-26 ◽  
Author(s):  
Mohammadreza Nakhaei ◽  
Jalil Ghanbarzadeh ◽  
Samin Alavi ◽  
Sahar Amirinejad ◽  
Hamidreza Rajatihaghi

ABSTRACT Aim There is limited and inconsistent information on some factors affecting visual shade selection. The aim of this study was to evaluate the influence of shade guide type and professional experience on shade-matching results. Materials and methods Thirty Dental students (DS), 30 General dentists (GDs) and 30 Dental specialists (S) participated in this study. The participants were asked to match six target tabs using two dental shade guides: Vitapan Classical (VC) and Vitapan 3D-Master (3D). An intraoral spectrophotometer was used for color measurement of target tabs and selected tabs. The color difference (Conflict of interest: NoneE) values between the target tab and selected tab were calculated. Data were analyzed using analysis of variance (ANOVA) and paired t-test (α = 0.05). Results of the first five best matches for each target tab were expressed as ΔE1 to ΔE5. Differences in the mean values of ΔE1 to ΔE5 between VC and 3D were compared using descriptive statistics. Results There were no significant differences among the three participating groups in ΔE values when the 3D was used (p = 0.389). However, significant differences were found with VC (p < 0.001). The ΔE values achieved from the 3D were significantly lower than those from VC for DS and S (p = 0.001 and p < 0.001, respectively). For each of the first five best matches, the mean ΔE values from the 3D were smaller than the corresponding values of VC. Conclusion The type of dental shade guide affected the shadematching results. The level of experience was not found to be an influential factor in shade matching when 3D-Master shade guide was used. Clinical significance Compared with Vitapan Classical shade guide, use of the Vitapan 3D-Master shade guide improves shade-matching results. How to cite this article Nakhaei M, Ghanbarzadeh J, Amirinejad S, Alavi S, Rajatihaghi H. The Influence of Dental Shade Guides and Experience on the Accuracy of Shade Matching. J Contemp Dent Pract 2016;17(1):22-26.


2019 ◽  
Vol 1 (1) ◽  
pp. 46-52 ◽  
Author(s):  
André Luis Faria-e-Silva

<P>Objective: This study aimed to assess possible differences in results provided by two shade guides and a spectrophotometer used to measure the color changes during tooth bleaching. </P><P> Methods: Fifty-six patients underwent two sessions of in-office tooth bleaching with a 35% hydrogen peroxide with a week of an interval between them. The color evaluation was performed using shade match with two guide scales (Vita Classical, and Vita Bleach Guide) and a spectrophotometer providing CieLab data. The color was assessed at baseline and 7 days after each session, and 30 days after the last session. Data from scales were arranged in scores according to lightness (lowest to highest) and the color changes were calculated based on baseline data. For CieLab data, &#916;L, &#916;a, &#916;b, and &#916;E were calculated for each assessment time. Differences between the color changes observed in each session were assessed by Wilcoxon test (&#945; = 0.05). Friedman`s test and One-way repeated measures ANOVA were used to analyze color changes among the assessment times. Spearman`s test was used to evaluate the correlation between the shade guide scores and data from Cielab. </P><P> Results: All methods of color measurement demonstrated any additional effect of second bleaching session on color change, and stable color after 30 days (p < 0.001 for all methods). Both shade guide scales presented low correlation coefficients with &#916;L, and moderate coefficients with &#916;b, Δa, and &#916;E. </P><P> Conclusion: Despite the weak/ moderate correlation among the methods used to measure tooth color, all methods showed similar results of tooth bleaching effectiveness.</P>


2011 ◽  
Vol 12 (1) ◽  
pp. 19-23 ◽  
Author(s):  
Carmen Llena ◽  
Esther Lozano ◽  
Jose Amengual ◽  
Leopoldo Forner

ABSTRACT Objective The objective of this study was to investigate the intra and interdevice reliability of two tooth color measurement devices: EasyShade (ES) and SpectroShade Micro (SSM). Materials and methods Tooth color was measured in six maxillary and mandibular. L*, a* and b* values and shade matches to VITA Classical and Vitapan 3D-Master shade guide systems were determined for all teeth. ÄE was assessed. Paired t-test and correlation coefficient (ICC) were used. Results Intradevices no significant differences (p > 0.05) were found between L*, a*, b*. Interdevice L* and b* were significantly higher for ES (p < 0.05), while a* was significantly higher for SSM (p < 0.05). ÄE showed no significant interdevice difference (p > 0.05). Intradevices ICC values were higher for ES but not significant (p > 0.05). Discussion The null hypotheses that they present no differences in their color measuring within devices or shade systems is accepted, but the results allow to reject the null hypotheses that they present no differences in their color measuring or shade systems between devices. Conclusion Both EasyShade (ES) and SpectroShade Micro (SSM) show excellent repeatability and so they can be used in office to evaluate tooth color or to assess color changes after treatment. Clinical significance Dental color can be diagnosed using dental spectrophotometers, allowing to detect in an objective way therapeutic dental color changes. How to cite this article Llena C, Lozano E, Amengual J Forner L. Reliability of Two Color Selection Devices in Matching and Measuring Tooth Color. J Contemp Dent Pract 2011; 12(1):19-23.


2013 ◽  
Vol 14 (1) ◽  
pp. 100-103 ◽  
Author(s):  
Hamid Jafarzadeh ◽  
Mohammadreza Nakhaei ◽  
Jalil Ghanbarzadeh ◽  
Shirin Keyvanloo ◽  
Samin Alavi

ABSTRACT Aim To evaluate the ability of dental students to match shades under three various light conditions. Materials and methods Sixty senior dental students participated in this study. All students were tested for color deficiency using Ishahara's tests. Nine classical vita shade tabs were randomly selected and their identification codes were concealed. The students were asked to match these 9 selected items by using a complete vita shade guide under three various light conditions (natural light, clinical light, and correcting light source). The chosen shade tabs were recorded and the correct matches were counted. Scores were calculated by adding the number of correct matches. Results The mean values of correct match scores with natural light, clinical light and correcting light source were 4.82, 4.75 and 6.82, respectively. There was no significant difference in correct matches scores between men and women, nor among various vita A, B, C and D shades. Conclusion The students showed a better performance in shade matching under the correcting light source than natural light and clinical light. Gender had no effect on shade matching selection and there was no difference in shade matching ability among vita A, B, C, D shades. Clinical significance Shade matching performance is significantly improved with correcting light source. How to cite this article Nakhaei M, Ghanbarzadeh J, Keyvanloo S, Alavi S, Jafarzadeh H. Shade Matching Performance of Dental Students with Three Various Lighting Conditions. J Contemp Dent Pract 2013;14(1):100-103.


2019 ◽  
pp. 22-27
Author(s):  
Cenk Yavuz ◽  
Ceyda Aksoy Tırmıkç ◽  
Burcu Çarklı Yavuz

Today the number of office workers has reached to an enormous number due to the fast-growing technology. Most of these office workers spend long hours in enclosed spaces with little/no daylight penetration. The lack of daylight causes physiological and psychological problems with the workers. At this point lighting systems become prominent as the source and the solution of the problem. Photometric flicker event which arises in the lighting systems can sometimes become visible and brings a lot of issues with it. In this paper, an experimental work has been done to investigate the effect of flicker. For this purpose, the flicker values of 3 different experiment rooms for different lighting conditions and scenarios have been measured and a questionnaire study has been carried out in the experiment rooms with 30 participants. In conclusion, the effect of the flicker event on the volunteers have been classified and some methods have been proposed not to experience flicker effects.


2019 ◽  
pp. 4-8
Author(s):  
Tadej Glažar ◽  
Marjeta Zupancic ◽  
Samo Kralj ◽  
Robert Peternelj

The Real Estate Fund of Pension and Disability Insurance (Nepremicninski Sklad) in Slovenia, founded in1997 is the owner of 3255 properties in 116 locations throughout the country and is intended for solving housing issues of pensioners of 65 years or older and other elderly persons who are allowed independently to live. The lease contracts are concluded for an indefinite period of time. The aim and vision of the Fund is to improve the quality of life for the elderly tenants by adapting the living environment, the flats and surroundings according to the physical needs of aging tenants. Homes for seniors often have low light levels and poor light spectrum caused by fluorescent or incandescent lighting. Demographic changes in most European countries show rising average life expectancy which means that the number of people with weak visual capacity or visual impairment is increasing. Equally the risks of injuries due to poor lighting conditions are increasing, e.g. missing a step resulting in a hip joint fracture. Better lighting conditions are of critical importance for aging population, as stated also in the recently published CIE227:2017. To facilitate safe environment for the elderly, the Fund in 2013 initiated a lighting research study that should provide facts and evidence for a lighting standard for their own premises.


Sign in / Sign up

Export Citation Format

Share Document