scholarly journals Effect of internal bleaching agents on the bond strength of glass fiber posts to root dentine

2016 ◽  
Vol 31 (3) ◽  
pp. 120
Author(s):  
Josemar Martins Ferreira ◽  
Sara Rodrigues Renovato ◽  
Fernanda Ribeiro Santana ◽  
Daniel De Almeida Decurcio ◽  
Carlos José Soares ◽  
...  

Objective: This study evaluated the effect of internal bleaching agents on the bond strength of glass fiber posts to root dentine.Methods: Seventy bovine teeth were divided into 7 experimental groups (n=10) according to the bleaching agent used: SpH – sodium perborate + 20% hydrogen peroxide; SpW – sodium perborate + distilled water; Cp37 – 37% carbamide peroxide; Cp16 – 16% carbamide peroxide; Cp10 – 10% carbamide peroxide; H – 35% hydrogen peroxide; C – no bleaching agent (control). After bleaching, posts were cemented with a self-adhesive resin cement (RelyX U100) and the roots were crosssectioned to obtain two discs from each third. The posts underwent micropush-out testing, and bond strength values (MPa) were analyzed using ANOVA in a split-plot arrangement and the Tukey test (p<0.05). Failure mode was evaluated under confocal microscopy.Results: There were no significant differences between the control and bleaching agent groups. Bond strength was greater in the cervical third of the 16% carbamide peroxide (Cp16) group than in the sodium perborate + 20% hydrogen peroxide (SpH) group. The cervical third had a higher bond strength than the apical third in the 10% carbamide peroxide (Cp10), 16% carbamide peroxide (Cp16) and sodium perborate + distilled water (SpW) groups, and no significant differences in the other groups. Adhesive cement-dentine failure was prevalent in all groups.Conclusion: The use of internal bleaching agents did not decrease the bond strength of glass fiber posts to root dentin.

2016 ◽  
Vol 27 (5) ◽  
pp. 592-598 ◽  
Author(s):  
Regina Maria Helen-Cot Marcos ◽  
◽  
Gustavo Ross Kinder ◽  
Edson Alfredo ◽  
Tarcisio Quaranta ◽  
...  

Abstract The objective of the present study was to evaluate the influence of resin cement thickness on the bond strength of prefabricated and customized glass fiber posts after storage in distilled water. Thirty human uniradicular roots were treated endodontically. The roots were divided into 3 groups: THIN (thin cement layer) - post space preparation with #0.5 drill and cementation of #0.5 post; THICK (thick cement layer) - post space preparation with #1 drill and cementation of #0.5 post; and CUSTOM (customized cement layer) - post space preparation with #1 drill and cementation of a customized post (#0.5 glass fiber posts customized with resin composite). All posts were luted with self-adhesive resin cement. The push-out test was carried out after storage for 24 h and 90 days in distilled water at 37 °C. The data were analyzed with three-way ANOVA and Tukey's test (a=0.05). Bond strengths were significantly higher for CUSTOM (9.37 MPa), than for THIN (7.85 MPa) and THICK (7.07 MPa), which were statistically similar. Considering the thirds, the bond strength varied in the sequence: apical (7.13 MPa) < middle (8.22 MPa) = coronal (8.94 MPa). Bond strength for 24 h storage was significantly higher (8.80 MPa) than for 90-day storage (7.40 MPa). It may be concluded that the thickness of resin cement influenced the bond strength of glass fiber posts. The customized posts presented higher bond strength. Storage in water for 90 days affected negatively the values of bond strength, especially for thick cement layers in the apical third.


2019 ◽  
Vol 48 ◽  
Author(s):  
Marciano de Freitas BORGES ◽  
Gabriela Simões TEIXEIRA ◽  
Anelise Fernandes MONTAGNER ◽  
Alexandre Henrique SUSIN

Abstract Introduction Glass-fiber posts are used in order to improve the retention of restorations in endodontically treated teeth. Objective To evaluate the bond strength of glass-fiber posts submitted to different surface treatments and cemented to the root canal dentin with self-adhesive resin cement. Material and method Thirty roots of human canines were prepared and divided according to two factors: surface treatments (silane, 35% hydrogen peroxide, or sodium bicarbonate) and root thirds (cervical and middle thirds). The glass-fiber posts were cemented with self-adhesive resin cement (RelyX U200). After 24 h, the specimens were prepared for microtensile bond strength test (hourglass format), fracture pattern and micromorphological assessment by scanning electronic microscopy, in order to measure the cement line. Result The data (MPa and µm) were submitted to two-way ANOVA and Tukey’s test (α = 5%). The surface treatments influenced the bond strength of the posts cemented with self-adhesive resin cement (p<0.00). The mean bond strength (standard deviations) differed according to the region of root dentin (p<0.00): the cervical region (Control: 19.16MPa (3.71); Silane: 25.65MPa (4.04); Hydrogen peroxide: 24.43MPa (3.16); Sodium bicarbonate: 37.42MPa (8.27)) showed higher bond strength values than the middle third of the root (Control: 14.66MPa (4.65); Silane: 12.52MPa (5.03); Hydrogen peroxide: 10.64MPa (3.33); Sodium bicarbonate: 10.87MPa (2.49)). Conclusion Treatment of the glass-fiber post surface with chemical and physical agents increased the bond strength of the cement-post-dentin interface in the cervical third and the treatment with Sodium bicarbonate showed better results in bond strength.


2014 ◽  
Vol 39 (4) ◽  
pp. 303 ◽  
Author(s):  
Maryam Khoroushi ◽  
Hamid Mazaheri ◽  
Pardis Tarighi ◽  
Pouran Samimi ◽  
Navid Khalighinejad

2016 ◽  
Vol 45 (4) ◽  
pp. 227-233
Author(s):  
Adriana Rosado Valente ANDRIOLI ◽  
Margareth COUTINHO ◽  
Andréa Araújo de VASCONCELLOS ◽  
Milton Edson MIRANDA

Abstract Introduction The correct use of glass fiber posts in endodontically treated teeth is essential for the clinical success of restorative treatment. Objective This study evaluated the push-out shear bond strength of relined (R) or non-relined (NR) glass fiber posts, cemented with self-adhesive resin cement [RelyXTM U100 (U100)] and conventional resin cement [RelyXTM ARC (ARC)]. Material and method Sixty human single-rooted teeth were endodontically treated and divided into ARC-NR; U100-NR; ARC-R; U100-R groups. The teeth were sectioned into cervical, middle and apical thirds, and subjected to the push-out test. Bond strength was analyzed by the Friedman test; cement and post types were compared by the Mann Whitney test. The pattern of failures was evaluated with digital camera through images at 200x magnification, and was classified as adhesive (at the cement/dentin or cement/post interface), cohesive (cement or post), and mixed failures. Result In ARC-NR, bond strength values were higher in the cervical third; in U100-NR and ARC-R they were similar between the thirds. In U100-R, in the cervical and middle thirds the bond strength values were similar, and there was lower value in the apical third. For non-relined glass fiber posts, the highest mean bond strength values were observed with self-adhesive resin cement. Whereas, relined posts cemented with conventional resin cement had stronger cement layer in comparison with non-relined fiber posts. Conclusion The post relining technique was efficient in ARC-R. ARC-NR and U100-R showed improved bond strength in the cervical region of canal walls. The main failures were adhesive at the cement-post interface.


2015 ◽  
Vol 26 (2) ◽  
pp. 141-145 ◽  
Author(s):  
Marcela G. Borges ◽  
André L. Faria-e-Silva ◽  
Paulo C. F. Santos-Filho ◽  
Fernanda P. Silva ◽  
Luís R. M. Martins ◽  
...  

Despite several advantages associated with pre-fabricated glass-fiber posts, the coronal portion of these posts must be cut to allow their use in various clinical situations. However, cutting the cemented post can generate stress on the bonding interface and affect the bond strength. The aim of this study was to investigate the effect the of fiber post cutting on the bond strength of root canals. Sixty bovine incisor roots were included in resin cylinders with simulated periodontal ligaments. Glass-fiber posts were luted using regular resin cement RelyX ARC (3M ESPE) or self-adhesive cement RelyX Unicem (3M ESPE). The posts were cut prior to cementation, immediately after luting or after building up the core (n=10). After storage for 24 h, the samples were cut and subject to push-out testing using a mechanical testing machine (EMIC DL 2000). Data were analyzed using two-way ANOVA (resin cement x moment of post cutting) and Tukey's post hoc test (α=0.05). The moment of fiber post cutting did not affect the bond strength when Unicem was used. However, the bond strength was reduced when ARC was used and when the post was cut immediately. In conclusion, the moment of fiber post cutting may affect the retention of root canal posts when a regular resin cement is used.


2016 ◽  
Vol 17 (2) ◽  
pp. 119-124 ◽  
Author(s):  
Lourenço Correr-Sobrinho ◽  
Daniele M da Silveira-Pedrosa ◽  
Luis RM Martins ◽  
Mário AC Sinhoreti ◽  
Manoel D Sousa-Neto ◽  
...  

ABSTRACT Aim To evaluate the push-out bond strength (BS) of direct anatomic posts (DAPs) and conventional fiber posts (CFPs) cemented with different luting agents in different thirds of flared root canals. Materials and methods A total of 60 human single-rooted canine teeth were transversally sectioned 16 mm from the radicular apex. After endodontic treatment, canals were flared with diamond burs. Samples were divided into six groups according to post type and luting agent: DAP and RelyX U100 (RXU); DAP and RelyX ARC (RXA); DAP and RelyX Luting 2 (RXL); CFP and RXU; CFP and RXA; CFP and RXL. Roots were sectioned transversely into six 1-mm-thick slices. The push-out test was performed and failure modes were observed. Results The DAP groups (7.23 ± 2.05) showed highest BS values (p < 0.05) when compared with CFP (5.93 ± 1.76). RelyX U100 (8.17 ± 1.70) showed higher BS values (p < 0.05) than RXA (6.46 ± 1.38), and RXL (5.10 ± 1.65) showed the lowest values. Bond strength on the apical third was statistically lower (p < 0.05) than that on the other thirds of the root canals. There was a predominance of adhesive failure for all groups. Conclusion The DAPs improved retention in flared root canals, and RXU was the most effective luting agent. The apical third showed the lowest BS values. Clinical significance The relining procedure of fiber posts with composite and the proper selection of luting resin cement are important for increasing bonding effectiveness in flared root canals. How to cite this article da Silveira-Pedrosa DM, Martins LRM, Sinhoreti MAC, Correr-Sobrinho L, Sousa-Neto MD, Costa ED Jr, de F Pedrosa-Filho C, de Carvalho JR Jr. Push-out Bond Strength of Glass Fiber Posts Cemented in Weakened Roots with Different Luting Agents. J Contemp Dent Pract 2016;17(2): 119-124.


2019 ◽  
Vol 2019 ◽  
pp. 1-5
Author(s):  
Raneem S. Alofi ◽  
Ibraheem F. Alshiddi ◽  
Yasser F. AlFawaz ◽  
Abdulaziz Alsahhaf ◽  
Khulud Abdulrahman Al-Aali ◽  
...  

Objective. This in vitro study was designed to evaluate the influence of an Er,Cr:YSGG laser on the bond strength of zirconia and glass fiber posts with root dentin. Materials and methods. Ninety extracted single-rooted human teeth were randomized into 6 groups (n = 15/group) on the basis of different posts (zirconia/glass fiber) and Er,Cr:YSGG laser tips (axial and radial). Specimens were prepared for push-out testing with the help of a cutting machine; six slices (2 on each cervical, middle, and apical) of approximately 1 mm thickness were sectioned for all roots on a plane perpendicular to the long axis of the post. All specimens were placed into a universal testing machine with a defined 0.5 mm/min crosshead speed until the maximum failure load was obtained. Results. The highest mean push-out bond strength of the glass fiber and zirconia groups was achieved with laser treatment. The highest push-out bond strength was achieved with the axial fiber tip (7.63 ± 1.22 MPa), and the lowest was achieved with a radial fiber tip of the glass fiber group (6.98 ± 0.96 MPa). ANOVA showed a statistically significant difference between the groups (p=0.041). The mean push-out bond strength was found to be higher with an axial fiber tip for both cervical and apical segments in the glass fiber and zirconia groups (p<0.05). The independent t-test resulted in the overall highest mean push-out bond strength in the apical segments (p=0.026). Conclusion. Within the limits of the present in vitro research study, an enhancement in the push-out bond strength of resin cement, mainly in the cervical region of the root canal, was achieved after irradiation with an Er,Cr:YSGG laser using an axial fiber tip.


2019 ◽  
Vol 26 ◽  
pp. 224-228 ◽  
Author(s):  
Matheus Albino Souza ◽  
Laís Vargas Bonacina ◽  
Rafaela Ricci ◽  
Marina Gabrieli Padilha Rauber ◽  
Natalia Zuchi ◽  
...  

2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Adricyla Teixeira Rocha ◽  
Leticia Machado Gonçalves ◽  
Ana Júlia de Carvalho Vasconcelos ◽  
Etevaldo Matos Maia Filho ◽  
Ceci Nunes Carvalho ◽  
...  

Aim. The aim of the study was to evaluate, by means of the push-out test, the effect of the anatomical customization of the fiber post on the bond strength of a self-adhesive resin cement. Methods. Twelve endodontically treated, human, upper central incisors were randomly divided into two groups (n=6): control (glass fiber posts cemented with Relyx® U200) and customized (glass fiber posts anatomically customized with translucent composite resin cemented with Relyx U200). The roots were sectioned into three slices, cervical, middle, and apical, and photographed with a digital camera attached to a stereomicroscopic loupe. The images were analyzed by software, for evaluation of the cement line. The slices were subsequently submitted to the push-out test until the post had completely extruded, and the fracture mode was analyzed with a stereomicroscopic loupe. Results. The results showed significant differences between the groups in the different root thirds in relation to the area occupied by air bubbles (p<0.05). Bond strength, when all the thirds are considered, was 8.77 ± 4.89 MPa for the control group and 16.96 ± 4.85 MPa for the customized group. Conclusion. The customized group showed greater bond resistance than the control group and a more uniform cement layer.


Sign in / Sign up

Export Citation Format

Share Document