Short vs. regular length implants to rehabilitate partially edentulous mandible: a 2-year prospective split-mouth clinical study

Author(s):  
Manrique Fonseca ◽  
Mireia Haro-Adanez ◽  
Stefano Pieralli ◽  
Miha Bresavscek ◽  
Burak Yilmaz ◽  
...  

Many studies have evaluated short implants (SIs); however, it is still unclear whether SIs are reliable and can be used to simplify surgical and prosthetic protocols with successful clinical outcomes. The aim of this non-random, conveniently sampled, prospective, split-mouth study was to compare the clinical outcomes when short (SI) (≤8 mm) or regular-length implants (RIs) (>10 mm) were used in the posterior mandible two years after the delivery of splinted reconstructions. Each participant (N=10) received four implants in the posterior mandible; two SIs were placed on one side, and two RIs were placed contra-laterally. Implants were restored with splinted, screw-retained, porcelain-fused-to-metal reconstructions. Survival and success rates, peri-implant marginal bone level (MBL), and soft tissue parameters were evaluated. No participant drop-outs were recorded. Both types of implants showed 100% success and survival rates. From prosthetic delivery to 24 months post-loading, bone remineralization of +0.40 mm for the SIs and +0.36 mm for the RIs was observed without statistically significant differences in MBL between the implant types (p=0.993). SIs showed significantly higher (p=0.001) clinical attachment level (CAL) and probing depth (PD) values. Chipping occurred in one situation in the RI group resulting in a 97.5% prosthetic success rate, which was 100% for the SIs. After 2 years, SIs with splinted reconstructions showed comparable clinical outcomes to those of RIs. Further long-term controlled clinical studies with balanced experimental designs evaluating random and larger populations are required to corroborate these findings.

2012 ◽  
Vol 2012 ◽  
pp. 1-8 ◽  
Author(s):  
Diego Lops ◽  
Eriberto Bressan ◽  
Gianluca Pisoni ◽  
Niccolò Cea ◽  
Boris Corazza ◽  
...  

Purpose.Evaluation of the short implant (8 mm in height) long-term prognosis and of the implant site influence on the prognosis.Methods.A longitudinal study was carried out on 121 patients (57 males and 64 females) consecutively treated with 257 implants. 108 implants were short.Results.Four (3.6%) short implants supporting fixed partial prostheses failed. Similarly, three standard implants supporting fixed partial prostheses and one supporting single-crown prosthesis failed. Mean marginal bone loss (MBL) and probing depth (PD) of short and standard implants were statistically comparable (P>.05). The 20-year cumulative survival rates of short and standard implants were 92.3 and 95.9%, respectively. The cumulative success rates were 78.3 and 81.4%. The survival rates of short implants in posterior and anterior regions were comparable: 95 and 96.4%, respectively. The difference between survival rates was not significant (P>.05).Conclusions.The high reliability of short implants in supporting fixed prostheses was confirmed. Short and standard implants long-term prognoses were not significantly different. The prognosis of short implants in posterior regions was comparable to that of in anterior regions. Nevertheless, a larger sample is required to confirm this trend.


2018 ◽  
Vol 44 (4) ◽  
pp. 250-259 ◽  
Author(s):  
Mireia Haro Adánez ◽  
Miha Brezavšček ◽  
Kirstin Vach ◽  
Manrique Fonseca ◽  
Wael Att

In many cases, due to anatomical limitations, the placement of regular-length implants cannot be facilitated without the performance of advanced surgical procedures. However, these are associated with morbidity, prolonged treatment time, and costs. To overcome such disadvantages, short implants were introduced. The aim of this prospective pilot split-mouth study was to compare the clinical outcome between short implants (7 mm) and regular-length (≥10 mm) implants placed in the posterior mandible after 1 year of prosthetic delivery. Ten patients received 4 implants in the posterior mandible. Two short implants were placed in one side and 2 regular-length implants were placed contralaterally. These were restored by means of splinted screw-retained metal-ceramic crowns. Marginal bone loss (MBL) and soft-tissue parameters were compared. No implant failed. Both types of implants showed success rates of 90% and survival rates of 100%. From prosthetic delivery to 1 year post-loading a bone gain of +0.29 mm for short implants and +0.19 mm for regular-length implants was present without showing any statistically significant differences in MBL between the 2 implant types (P > .05). Bleeding on probing, clinical attachment level, probing depth, and crown-to-implant ratio did not show any statistically significant differences between the 2 implant lengths (P > .05). One case of chipping occurred in the regular-length implant group, leading to a prosthetic survival rate of 95%. Short implants showed a prosthetic survival rate of 100%. After 1 year, short implants showed comparable clinical outcomes to that of regular-length implants, making them a viable treatment option in the posterior mandible.


Pharmaceutics ◽  
2020 ◽  
Vol 12 (11) ◽  
pp. 1016
Author(s):  
Sung-Wook Yoon ◽  
Myong-Ji Kim ◽  
Kyeong-Won Paeng ◽  
Kyeong Ae Yu ◽  
Chong-Kil Lee ◽  
...  

Background: Local delivery agents (LDA) have the advantage of delivering the antibiotics at high concentrations to the targeted sites. However, the constant flow of gingival crevicular fluids and saliva may restrict their efficacy. Therefore, the drug sustainability and pharmacodynamic properties of any proposed LDA should be evaluated. Methods: Four dental implants were placed unilaterally in the edentulous mandible of six beagle dogs. Peri-implantitis were experimentally induced using silk-ligatures. Each implant was randomly allocated to receive one of the following four treatments: (i) MC (Chitosan-alginate (CA) minocycline), (ii) MP (CA-without minocycline), (iii) PG (Polyacrylate-glycerin minocycline), and (iv) Control (mechanical debridement only). Mechanical therapies and LDAs were administered into the gingival sulcus two times at a 4-week interval. Drug sustainability as well as clinical, radiographical, and immunohistochemical (IHC) analyses were conducted to evaluate the efficacies of treatments. Results: Reduced mean probing depth was observed in all of the test groups after the second delivery. A minimal marginal bone level change was observed during the treatment period (MP (−0.06 ± 0.53 mm) to PG (−0.25 ± 0.42 mm)). The distribution of IHC cell marker analysis of all targeted antibodies ranged from 6.34% to 11.33%. All treatment outcomes between the test groups were comparable. A prolonged retention of LDA was observed from CA microspheres (MC and MP) at both administrations (p < 0.017) and prolonged sustainability of bacteriostatic effect was observed from MC compared to PG after the second administration (p < 0.05). Conclusions: Prolonged retention of CA microspheres was observed and the longer bacteriostatic effect was observed from the MC group. Mechanical debridement with adjunct LDA therapy may impede peri-implantitis progression, however, prolonged drug action did not lead to improved treatment outcome.


2019 ◽  
Vol 8 (9) ◽  
pp. 1305 ◽  
Author(s):  
Simone Marconcini ◽  
Enrica Giammarinaro ◽  
Ugo Covani ◽  
Eitan Mijiritsky ◽  
Xavier Vela ◽  
...  

Background: Early peri-implant bone loss has been associated to long-term implant-prosthetic failure. Different technical, surgical, and prosthetic techniques have been introduced to enhance the clinical outcome of dental implants in terms of crestal bone preservation. The aim of the present cohort study was to observe the mean marginal bone level around two-part implants with gingivally tapered abutments one year after loading. Methods: Mean marginal bone levels and change were computed following radiological calibration and linear measurement on standardized radiographs. Results: Twenty patients who met the inclusion criterion of having at least one implant with the tapered prosthetic connection were included in the study. The cumulative implant success rate was 100%, the average bone loss was −0.18 ± 0.72 mm, with the final bone level sitting above the implant platform most of the time (+1.16 ± 0.91 mm). Conclusion: The results of this cohort study suggested that implants with tapered abutments perform successfully one year after loading and that they are associated with excellent marginal bone preservation, thus suggesting that implant-connection macro-geometry might have a crucial role in dictating peri-implant bone levels.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
H J Kim ◽  
M A Kim ◽  
D I Lee ◽  
H L Kim ◽  
D J Choi ◽  
...  

Abstract Background Ischemic heart disease (IHD) is a major underlying etiology in patients with heart failure (HF). Although the impact of IHD on HF is evolving, there is a lack of understanding of how IHD affects long-term clinical outcomes and uncertainty about the role of IHD in determining the risk of clinical outcomes by gender. Purpose This study aims to evaluate the gender difference in impact of IHD on long-term clinical outcomes in patients with heart failure reduced ejection fraction (HFrEF). Methods Study data were obtained from the nationwide registry which is a prospective multicenter cohort and included patients who were hospitalized for HF composed of 3,200 patients. A total of 1,638 patients with HFrEF were classified into gender (women 704 and men 934). The primary outcome was all-cause death during follow-up and the composite clinical events of all-cause death and HF readmission during follow-up were also obtained. HF readmission was defined as re-hospitalization because of HF exacerbation. Results 133 women (18.9%) were died and 168 men (18.0%) were died during follow-up (median 489 days; inter-quartile range, 162–947 days). As underlying cause of HF, IHD did not show significant difference between genders. Women with HFrEF combined with IHD had significantly lower cumulative survival rate than women without IHD at long-term follow-up (74.8% vs. 84.9%, Log Rank p=0.001, Figure 1). However, men with HFrEF combined with IHD had no significant difference in survival rate compared with men without IHD (79.3% vs. 83.8%, Log Rank p=0.067). After adjustment for confounding factors, Cox regression analysis showed that IHD had a 1.43-fold increased risk for all-cause mortality independently only in women. (odds ratio 1.43, 95% confidence interval 1.058–1.929, p=0.020). On the contrary to the death-free survival rates, there were significant differences in composite clinical events-free survival rates between patients with HFrEF combined with IHD and HFrEF without IHD in both genders. Figure 1 Conclusions IHD as predisposing cause of HF was an important risk factor for long-term mortality in women with HFrEF. Clinician need to aware of gender-based characteristics in patients with HF and should manage and monitor them appropriately and gender-specifically. Women with HF caused by IHD also should be treated more meticulously to avoid a poor prognosis. Acknowledgement/Funding None


2019 ◽  
Vol 2019 ◽  
pp. 1-14 ◽  
Author(s):  
Fernanda Faot ◽  
Amália Machado Bielemann ◽  
Alessandra Julie Schuster ◽  
Raissa Micaella Marcello-Machado ◽  
Altair Antoninha Del Bel Cury ◽  
...  

Aim. To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. Methods. Thirty-one edentulous patients received two narrow implants (2.9x10mm, Facility NeoPoros) to retain mandibular overdentures. The implants were categorized in four groups according to their IT: (G1) IT > 10 Ncm; (G2) IT ≥ 10Ncm and ≤ 30 Ncm; (G3) IT >30Ncm and < 45Ncm; (G4) IT ≥ 45Ncm, and all implants were loaded after 3 months of healing. The following clinical outcomes were evaluated 1, 3, 6, and 12 months after implant insertion: (i) peri-implant tissue health (PH), gingival index (GI), plaque index (PI), calculus presence (CP), probing depth (PD), and bleeding on probing (BOP); (ii) implant stability quotient (ISQ) by resonance frequency analysis; and (iii) IL-1β and TNF-α concentration in the peri-implant crevicular fluid. The marginal bone level (MBL) and changes (MBC) were evaluated. The Chi2 test, Kruskal-Wallis test, mixed-effects regression analysis, and the Kendall rank correlation coefficient were used for statistical analysis (α = 5%). Results. G1 presented the highest PD at all evaluated periods. G2 presented higher PI at month 6 and 12. G4 showed increased GI at month 3 and 12 and more CP at month 1 (p=.003). G2 and G4 had higher ISQ values over the study period, while those from G1 and G3 presented lower ISQ values. The IL-1β concentration increased until month 12 and was independent of IT and bone type; G4 had a higher IL-1β concentration in month 3 than the other groups (p=.015). The TNF-α release was negatively correlated with IT, and TNF-α release was highest in G1 at month 12. The MBL immediately after surgery and the MBC at month 12 were similar between the groups, and G4 presented a positive MBC at month 12. The survival and success rates were 75% for G1, 81.3% for G2, 64.3% for G3, and 95% for G4. Conclusion. The IT did not influence the clinical outcomes and the peri-implant immunoinflammatory responses and was weakly correlated with the narrow dental implants primary stability. The observed success rates suggest that the ideal IT for atrophic fully edentulous patients may deviate from the standardized IT of 32 Ncm.


2017 ◽  
Vol 46 (5) ◽  
pp. 1243-1250 ◽  
Author(s):  
Seong-Il Bin ◽  
Kyung-Wook Nha ◽  
Ji-Young Cheong ◽  
Young-Soo Shin

Background: It is unclear whether lateral meniscal allograft transplantation (MAT) procedures lead to better clinical outcomes than medial MAT. Hypothesis: The survival rates are similar between medial and lateral MAT, but the clinical outcomes of lateral MAT are better than those of medial MAT at final follow-up. Study Design: Meta-analysis. Methods: In this meta-analysis, we reviewed studies that assessed survival rates in patients who underwent medial or lateral MAT with more than 5 years of follow-up and that used assessments such as pain and Lysholm scores to compare postoperative scores on knee outcome scales. The survival time was considered as the time to conversion to knee arthroplasty and/or subtotal resection of the allograft. Results: A total of 9 studies (including 287 knees undergoing surgery using medial MAT and 407 with lateral MAT) met the inclusion criteria and were analyzed in detail. The proportion of knees in which midterm (5-10 years) survival rates (medial, 97/113; lateral, 108/121; odds ratio [OR] 0.71; 95% CI, 0.31-1.64; P = .42) and long-term (>10 years) survival rates (medial, 303/576; lateral, 456/805; OR 0.78; 95% CI, 0.52-1.17; P = .22) were evaluated did not differ significantly between medial and lateral MAT. In addition, both groups had substantial proportions of knees exhibiting midterm survivorship (85.8% for medial MAT and 89.2% for lateral MAT) but much lower proportions of knees exhibiting long-term survivorship (52.6% for medial MAT and 56.6% for lateral MAT). In contrast, overall pain score (medial, 65.6 points; lateral, 71.3 points; 95% CI, −3.95 to −0.87; P = .002) and Lysholm score (medial, 67.5 points; lateral, 72.0 points; 95% CI, −10.17 to −3.94; P < .00001) were significantly higher for lateral MAT compared with medial MAT. Conclusion: Meta-analysis indicated that 85.8% of medial and 89.2% of lateral meniscal allograft transplants survive at midterm (5-10 years) while 52.6% of medial and 56.6% of lateral meniscal allograft transplants survive long term (>10 years). Patients undergoing lateral meniscal allograft transplantation demonstrated greater pain relief and functional improvement than patients undergoing medial meniscal allograft transplantations.


10.29007/3724 ◽  
2018 ◽  
Author(s):  
Eun-Kyoo Song ◽  
Jong-Keun Seon ◽  
Dong-Hyun Lee ◽  
Je-Hyoung Yeo

Total knee arthroplasty using navigation system is known to be more effective than conventional methods in achieving more accurate bone resection and neutral alignment.1 Mobile bearing is also known to reduce wear and automatically correct rotational malalignment of the tibia but the long-term follow-up results of more than 10 years are extremely rare.2, 3 The purpose of this study is to investigate the results of clinical and radiologic long-term follow-up and complications of total knee arthroplasty using navigation and multi-directional mobile bearing.From 2003 to 2006, a total of 111 navigation TKAs using multi-directional mobile bearing design were carried out and reviewed retrospectively. TKAs were performed by two experienced surgeons at one institute. Of the 111 patients, 102 were women and 9 were men. The mean duration of follow-up was 11.4 ± 1.0 years (range, 10.1 to 14.08 years). Clinical outcomes were evaluated in terms of Knee Society Score, Hospital for Special Surgery score, Western Ontario and McMaster University (WOMAC) score, range of motion and complications. Long-term radiological outcomes and survival rates were evaluated at least 10 years.Average preoperative HSS score was 66.5 ± 9.8 and KSS pain and function score were 25.0 ± 11.8 and 44.5 ± 12.3, respectively. Scores improved to 94.1 ± 8.2, 46.6 ± 11.6 and 88.2 ± 14.6 at the last follow up, respectively. Mean preoperative WOMAC scores of 75.8 ± 16.5 improved to 13.8 ± 16.0 at last follow-up. Five knees required re-operation, two for liner breakage, one for liner wear, one for distal femoral fracture and one for infection. The estimated 10-year prosthesis survival rates for any reason and for prosthesis-related problems were 95.5% and 97.4% , respectively.TKAs using each techniques resulted in similar good clinical outcomes and postoperative leg alignments. Robotic and navigation TKA appeared to reduce the number of postoperative leg alignment outliers and revision rate compared to conventional TKA.


Sign in / Sign up

Export Citation Format

Share Document