Remote magnetic navigation for catheter ablation of atrioventricular nodal reentrant tachycardia: a systematic review and meta-analysis

2013 ◽  
Vol 11 (7) ◽  
pp. 829-836 ◽  
Author(s):  
Mohammed Shurrab ◽  
Asaf Danon ◽  
Alexander Crystal ◽  
Banafsheh Arouny ◽  
Irving Tiong ◽  
...  
2018 ◽  
Vol 2018 ◽  
pp. 1-8
Author(s):  
Xiao-yu Liu ◽  
Hai-feng Shi ◽  
Jie Zheng ◽  
Ku-lin Li ◽  
Xiao-xi Zhao ◽  
...  

Objective. The objective of this study was to investigate the impact of left atrial (LA) size for the ablation of atrial fibrillation (AF) using remote magnetic navigation (RMN). Methods. A total of 165 patients with AF who underwent catheter ablation using RMN were included. The patients were divided into two groups based on LA diameter. Eighty-three patients had small LA (diameter <40 mm; Group A), and 82 patients had a large LA (diameter ≥40 mm; Group B). Results. During mapping and ablation, X-ray time (37.0 (99.0) s vs. 12 (30.1) s, P<0.001) and X-ray dose (1.4 (2.7) gy·cm2 vs. 0.7 (2.1) gy·cm2, P=0.013) were significantly higher in Group A. No serious complications occurred in any of the patients. There was no statistical difference in the rate of first anatomical attempt of pulmonary vein isolation between the two groups (71.1% vs. 57.3%, P=0.065). However, compared with Group B, the rate of sinus rhythm was higher (77.1% vs. 58.5%, P<0.001) during the follow-up period. More patients in Group A required a sheath adjustment (47/83 vs. 21/82, P<0.001), presumably due to less magnets positioned outside of the sheath. In vitro experiments with the RMN catheter demonstrated that only one magnet exposed created the sheath affects which influenced the flexibility of the catheter. Conclusions. AF ablation using RMN is safe and effective in both small and large LA patients. Patients with small LA may pose a greater difficulty when using RMN which may be attributed to the fewer magnets beyond the sheath. As a result, the exposure of radiation was increased. This study found that having at least two magnets of the catheter positioned outside of the sheath can ensure an appropriate flexibility of the catheter.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
O.M Aldaas ◽  
F Lupercio ◽  
C.L Malladi ◽  
P.S Mylavarapu ◽  
D Darden ◽  
...  

Abstract Background Catheter ablation improves clinical outcomes in symptomatic atrial fibrillation (AF) patients with heart failure (HF) with reduced ejection fraction (HFrEF). However, the role of catheter ablation in HF patients with a preserved ejection fraction (HFpEF) is less clear. Purpose To determine the efficacy of catheter ablation of AF in patients with HFpEF relative to those with HFrEF. Methods We performed an extensive literature search and systematic review of studies that compared AF recurrence at one year after catheter ablation of AF in patients with HFpEF versus those with HFrEF. Risk ratio (RR) 95% confidence intervals were measured using the Mantel-Haenszel method for dichotomous variables, where a RR&lt;1.0 favors the HFpEF group. Results Four studies with a total of 563 patients were included, of which 312 had HFpEF and 251 had HFrEF. All patients included were undergoing first time catheter ablation of AF. Patients with HFpEF experienced similar recurrence of AF one year after ablation on or off antiarrhythmic drugs compared to those with HFrEF (RR 0.87; 95% CI 0.69–1.10, p=0.24), as shown in Figure 1. Recurrence of AF was assessed with electrocardiography, Holter monitoring, and/or event monitoring at scheduled follow-up visits and final follow-up. Conclusion Based on the results of this meta-analysis, catheter ablation of AF in patients with HFpEF appears as efficacious in maintaining sinus rhythm as in those with HFrEF. Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document