scholarly journals Cyclic Fatigue Resistance of Rotary NiTi Instruments after Simulated Clinical Use in Curved Root Canals

2013 ◽  
Vol 24 (2) ◽  
pp. 117-120 ◽  
Author(s):  
Oscar Faciola Pessoa ◽  
Juliana Melo da Silva ◽  
Giulio Gavini

The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments after simulated clinical use in curved root canals (40-degree, 5-mm radius curve). Thirty-six RaCe rotary NiTi files, size #5, taper 0.04, were divided into 3 groups: Groups A, B and C with one, three and five cycles of use, respectively. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. The data were analyzed statistically by ANOVA and Tukey's test (α=0.05). Five sets of clinically used files (group C) reached significantly lower cycle-numbers before fracture (mean=197.5 cycles) when compared with one set of clinically used files (mean=309.2) and three sets (mean=287.5). Results showed that the number of simulated clinical uses of RaCe instruments for shaping curved canals affects adversely the fatigue resistance of these instruments after five uses.

2020 ◽  
Vol 14 (2) ◽  
pp. 111-115 ◽  
Author(s):  
Gülsah Uslu ◽  
Mustafa Gündoğar ◽  
Taha Özyürek ◽  
Gianluca Plotino

Background. This study was conducted to compare the cyclic fatigue resistance of VDW.ROTATE,TruNatomy Prime, HyFlex CM, and 2Shape nickel-titanium (NiTi) rotary instruments in doublecurvedcanals in a simulated clinical environment. Methods. Eighty NiTi files were used for the fatigue testing in stainless steel canals compatible withinstrument sizes until fracture occurred (n=20): VDW.ROTATE (04./25#), TruNatomy Prime (04./26#),HyFlex CM (04./25#) and 2Shape TS04./25#( 1). For each instrument, the number of cycles to fracture(NCF) was calculated, and the fractured fragment length (FL) was measured. To verify that the fileswere fractured due to cyclic fatigue, the fractured surfaces of the files were evaluated under a scanningelectron microscope. Data were statistically analyzed using the Kruskal–Wallis and Student’s t-tests atthe %95 confidence level. Results. The failure of the files due to cyclic fatigue was first seen in the apical curvature before thecoronal curvature (P<0.05). The highest fatigue resistance was observed in VDW.ROTATE and HyFlexCM files in both curvatures (P<0.05). There were no significant differences in the fatigue resistancebetween the HyFlex CM and VDW.ROTATE files or between the 2Shape and the TruNatomy files(P>0.05). There was no difference in the fractured lengths of the files between the apical and coronalcurvatures (P>0.05). Conclusion. In artificial S-shaped root canals, VDW.ROTATE and HyFlex CM files exhibited higherfatigue resistance compared to 2Shape and TruNatomy files.


Author(s):  
Jader Camilo Pinto ◽  
Fernanda Ferrari Esteves Torres ◽  
Airton Oliveira Santos-Junior ◽  
Marco Antonio Hungaro Duarte ◽  
Juliane Maria Guerreiro-Tanomaru ◽  
...  

Abstract Objective The aim of this study was to investigate the effect of additional apical preparation using the ProDesign Logic (PDL) 50/.01 rotary heat-treated nickel–titanium (NiTi) file with a larger diameter and minimal taper for retreatment of curved root canals. Materials and Methods Mesial curved root canals of 12 mandibular molars were prepared using PDL 25/.06 and filled using the continuous wave of condensation technique and AH Plus sealer. After retreatment using ProDesign S (PDS) 25/.08, PDL 25/.06 and PDL 35/05, a complementary procedure was performed with PDL 50/.01. Microcomputed tomography (micro-CT) scanning was performed before and after retreatment procedures. The cyclic fatigue resistance of unused PDS 25/.08, PDL 25/.06, PDL 35/.05 and PDL 50/.01 instruments (n = 12) was evaluated in a stainless-steel device. Statistical Analysis Data on the volumes of the root canals and the remaining filling materials were submitted to the paired t-test. Cyclic fatigue resistance data was submitted to one-way ANOVA and Tukey’s tests (α = 0.05). Results Use of PDL 50/.01 decreased the remaining filling materials in the apical third (p < 0.05). The root canal volume was similar in the cervical and middle thirds before and after preparation using PDL 50/.01 (p > 0.05). PDL 50/.01 presented the highest cyclic fatigue resistance (p < 0.05). Conclusions Use of the PDL 50/.01 instrument as an additional apical preparation for retreatment of curved root canals improved filling material removal in the apical third, while maintaining the dentin in the cervical and middle thirds. In addition, PDL 50/.01 presented high-flexural resistance.


2020 ◽  
Vol 10 (2) ◽  
pp. 55-59
Author(s):  
Mehmet Adıgüzel ◽  
Faruk Öztekin

Aim: To evaluate the fracture resistance to cyclic fatigue of One Curve (Micro-Mega, Besancon, Cedex, France), One Shape (Micro-Mega), 2Shape (Micro-Mega) and EdgeFile X3 (EdgeEndo, Albuquerque, NM) files in simulated root canals. Methodology: One hundred and sixty nickel-titanium endodontic files were tested in simulated canals with single and s-shaped (double) curvatures. The One Curve (25/.06), One Shape (25/.06), 2Shape (25/.06) and EdgeFile X3 (25/.06) files were assessed (n=20 for each test). All the files were rotated up to fracture occurred. The number of cycles to fracture (NCF) was determined and also, the length of the fractured file part was measured. For statistical analysis, one-way analysis of variance and Tukey HSD tests were used (p < 0.05).   Results: NCF for all instrument groups were significantly higher in the single curvature canal compared to the s-shaped curvature canal (p < 0.05). The EdgeFile X3 had the highest fatigue resistance in both curvature groups. The NCF of the One Curve were higher than that of the One Shape and 2Shape files (p < 0.05). In the s-shaped curvature canal, the files inclined to fracture more often in the apical curvature compared to the coronal curvature. There was no statistically considerable difference in the length of the fractured parts among the four experiment groups in either the single or s-shaped canal curvatures (p > 0.05). Conclusion: Within the limitations of this study, fracture resistance to cyclic fatigue was the highest for the EdgeFile X3 group followed by the One Curve group and lowest for the 2Shape and One Shape group.   How to cite this article: Adıgüzel M, Öztekin F. Comparison of the resistance to cyclic fatigue of One Curve, One Shape, 2Shape and EdgeFile X3 Files in simulated single and S-shaped (double) curvatures. Int Dent Res 2020;10(2):55-59. https://doi.org/10.5577/intdentres.2020.vol10.no2.5   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


2014 ◽  
Vol 3 (2) ◽  
pp. 67-72 ◽  
Author(s):  
Alberto Dagna ◽  
Riccardo Beltrami ◽  
Marco Colombo ◽  
Marco Chiesa ◽  
Stefano Bianchi ◽  
...  

ABSTRACT The aim of this in vitro study was to compare the cyclic fatigue resistance of three single-use nickel-titanium (NiTi) instruments (One Shape, Reciproc and Wave One) after immersion in sodium hypochlorite (NaOCl) solution over several time periods. A total of 135 One Shape, Reciproc R25 and Wave One Primary were tested. The 45 files of the same brand were randomly assigned to three groups (n = 15) and submitted to the following immersion protocol: 1 minute in 5% NaOCl at 37°C, 5 minutes in 5% NaOCl at 37°C, no immersion (as control). Cyclic fatigue test was performed rotating/reciprocating all instruments in a stainless steel curved artificial canal (60° angle of curvature and 5 mm radius). The number of cycles to fracture (NCF) was determined by measuring the time to fracture. The data were compared for differences by using 2-way analysis of variance (p < 0.05). In general, resistance to cyclic fatigue was not significantly affected by immersion in NaOCl. Reciproc R2 showed the highest cyclic fatigue resistance in all groups compared to One Shape and Wave One. Immersion in NaOCl for 1 or 5 minutes did not reduce the cyclic fatigue resistance of NiTi single-use instruments significantly. Reciproc were more resistant, but the new rotary single-use One Shape instruments showed mechanical resistance similar to NiTi files developed for reciprocating motion. How to cite this article Dagna A, Beltrami R, Colombo M, Chiesa M, Bianchi S, Poggio C. Cyclic Fatigue Resistance of Three Single-use NiTi Instruments after Immersion in Sodium Hypochlorite. Int J Experiment Dent Sci 2014;3(2):67-72.


2021 ◽  
Vol 19 ◽  
pp. 228080002098740
Author(s):  
Haiyun Liu ◽  
Yanfeng Li ◽  
Guangquan Chai ◽  
Yuan Lv ◽  
Changjian Li ◽  
...  

Objective: To evaluate the effect of synchronous water irrigation on the fatigue resistance of nickel-titanium instrument. Methods: A standardized cyclic fatigue test models were established, and five types of nickel-titanium instruments (PTU F1, WO, WOG, RE, and M3) were applied. Each instrument was randomly divided into two groups ( N = 12). There was synchronous water irrigation in the experimental group, and no water irrigation in the control group. Besides, ProTaper Universal F1 was randomly divided into 10 groups ( N = 20). In the static group, nickel-titanium instruments were divided into one control group (no irrigation, N = 20) and six experimental group (irrigation, N = 20) based on different flow rate, angle and position; while in the dynamic group, instruments were divided into one control group (no irrigation, N = 20) and two experimental group (irrigation, N = 20) based on different flow rate. The rotation time (Time to Failure, TtF) of instruments was recorded and analyzed. Results: According to the static experiments, the TtF of instruments in all experimental groups was significantly higher than that in the static control group. Besides, the dynamic tests of PTU F1 showed that the TtF in the experimental group was significantly higher than that in the dynamic control group. Compared with control group, the TtF in the experimental groups increased by at least about 30% and up to 160%. The static and dynamic tests of PTU F1 showed that the TtF of nickel-titanium instrument in all experimental groups was significantly higher than that in the control group. However, there was no significant difference between any two experimental groups. Conclusion: Regardless of dynamic or static model, TtF with irrigation was longer than that with non-irrigation, indicating that synchronous irrigation can increase the fatigue resistance of nickel-titanium instrument. However, different irrigation conditions may have the same effect on the fatigue resistance.


Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5823
Author(s):  
Saulius Drukteinis ◽  
Vytaute Peciuliene ◽  
Ruta Bendinskaite ◽  
Vilma Brukiene ◽  
Rasmute Maneliene ◽  
...  

The better understanding of the clinically important behavioral features of new instrument systems has an important significance for the clinical endodontics. This study aimed to investigate the shaping and centering ability as well as cyclic fatigue resistance of HyFlex CM (CM), HyFlex EDM (EDM) and EdgeFile (EF) thermally treated nickel–titanium (NiTi) endodontic instrument systems. Sixty curved root canals of the mesial roots of mandibular molars were randomly assigned into three groups (n = 20) and shaped using CM, EDM and EF files up to the size 40 and taper 04 of the instruments. µCT scanning of the specimens before and after preparation was performed and the morphometric 2D and 3D parameters were evaluated in the apical, middle and coronal thirds of root canals. In each group, 40.04 instruments (n = 20) were subjected to the cyclic fatigue resistance test in artificial root canals at 37 °C temperature until fractures occurred, and the number of cycles to failure (NCF) was calculated. The fractographic analysis was performed using a scanning electron microscope, evaluating topographic features and surface profiles of the separated instruments. The one-way analysis of variance with post hoc Tuckey’s test was used for statistical analysis of the data; the significance level was set at 5%. All systems prepared the comparable percentage of root canal surface with the similar magnitude of canal transportation in all root thirds (p > 0.05), but demonstrated significantly different resistance to cyclic fatigue (p < 0.05). The most resistant to fracture was EF, followed by EDM and CM. The length of the fractured fragments was not significantly different between the groups, and fractographic analysis by SEM detected the typical topographic features of separated thermally treated NiTi instrument surfaces.


2018 ◽  
Vol 12 (4) ◽  
pp. 283-287 ◽  
Author(s):  
Gülşah Uslu ◽  
Taha Özyürek ◽  
Mustafa Gündoğar ◽  
Koray Yılmaz

Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files.


2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Suhad Jabbar Hamed Al-Nasrawi ◽  
Zuha Ayad Jaber ◽  
Nibrass Talib Al-Quraine ◽  
Abtesam Imhemed Aljdaimi ◽  
Sattar Jabbar Abdul-Zahra Al-Hmedat ◽  
...  

Peracetic acid (PAA) is widely used as a sterilizing/disinfecting agent, and, in endodontics, it has been introduced as a promising irrigant in root canal treatment. It has been used at different concentrations to achieve various functions. However, endodontic instruments in contact with PAA of a certain concentration may affect their fatigue resistance. Therefore, the aim of this study was to investigate the impact of PAA on the cyclic fatigue resistance of three commercial heat-treated nickel-titanium (NiTi) rotary files. Three types of heat-treated NiTi rotary files were selected: One Curve (OC), ProTaper Gold (PTG), and Wave One Gold (WOG). Each type was divided into three subgroups (n = 6 for each file type): (1) untreated instruments; (2) files immersed in 0.002% PAA; and (3) files immersed in 0.35% PAA. The performance of each file type was tested in a simulated canal. The number of cycles to fracture (NCF) was determined to assess cyclic fatigue resistance of the files. Independent sample t-test was applied to compare each treated file within a subgroup with its respective control group, and one-way ANOVA was used for comparison among the main groups. All types of tested files revealed a significant decline in the cyclic fatigue resistance after exposure to 0.002% PAA except the PTG ( P = 0.209 ). After exposure of the files to a higher concentration (0.35% PAA), a dramatic reduction was demonstrated by all the groups. Before and after exposure of the files to PAA, PTG displayed the highest cyclic fatigue resistance, followed by the WOG, while the OC showed the lowest resistance. Exposure of heated-treated NiTi files to PAA in a relatively high or low concentration adversely affects the cyclic fatigue resistance. The PTG files demonstrated the best performance among the tested types and can be disinfected with 0.002% PAA for clinical purpose.


2020 ◽  
Vol 46 (11) ◽  
pp. 1771-1775 ◽  
Author(s):  
Jussaro Alves Duque ◽  
Clovis Monteiro Bramante ◽  
Marco Antonio Hungaro Duarte ◽  
Murilo Priori Alcalde ◽  
Emmanuel João Nogueira Leal Silva ◽  
...  