scholarly journals SPEM: a state-of-the-art instrument for high resolution molecular imaging of small animal organs

2012 ◽  
Vol 10 (2) ◽  
pp. 209-215 ◽  
Author(s):  
Marilia Alves dos Reis ◽  
Jorge Mejia ◽  
Ilza Rosa Batista ◽  
Marycel Rosa Felisa Figols de Barboza ◽  
Solange Amorim Nogueira ◽  
...  

OBJECTIVE: To describe the Single Photon Emission Microscope (SPEM), a state-of-the-art instrument for small animal SPECT imaging, and characterize its performance presenting typical images of different animal organs. METHODS: SPEM consists of two independent imaging devices based on high resolution scintillators, high sensitivity and resolution Electron-Multiplying CCDs and multi-pinhole collimators. During image acquisition, the mouse is placed in a rotational vertical holder between the imaging devices. Subsequently, an appropriate software tool based on the Maximum Likelihood algorithm iteratively produces the volumetric image. Radiopharmaceuticals for imaging kidneys, heart, thyroid and brain were used. The mice were injected with 74 to 148 MBq/0,3mL and scanned for 40 to 80 minutes, 30 to 60 minutes afterwards. During this procedure, the animals remained under ketamine/xilazine anesthesia. RESULTS: SPEM images of different mouse organs are presented, attesting the imaging capabilities of the instrument. CONCLUSION: SPEM is an innovative technology for small animal SPECT imaging providing high resolution images with appropriate sensitivity for pre-clinical research. Its use with appropriate radiotracers will allow translational investigation of several animal models of human diseases, their pharmacological treatment and the development of potential new therapeutic agents.

2020 ◽  
Author(s):  
Jan V Hoffmann ◽  
Jan P Janssen ◽  
Takayuki Kanno ◽  
Takayuki Shibutani ◽  
Masahisa Onoguchi ◽  
...  

Abstract Background: Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector-configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT+).Methods: The new U-SPECT5-E with two stationary detectors was used for acquiring data with 99mTc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT+ for comparison. Results: Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT+. In the visually analysed sections of the reconstructed mini Derenzo phantom, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT+) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60-1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR.Conclusions: While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Jan V. Hoffmann ◽  
Jan P. Janssen ◽  
Takayuki Kanno ◽  
Takayuki Shibutani ◽  
Masahisa Onoguchi ◽  
...  

Abstract Background Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT+). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with 99mTc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT+ for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT+. In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT+) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.


2020 ◽  
Author(s):  
Jan V Hoffmann ◽  
Jan P Janssen ◽  
Takayuki Kanno ◽  
Takayuki Shibutani ◽  
Masahisa Onoguchi ◽  
...  

Abstract Purpose Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector-configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT+). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with 99mTc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT+ for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT+. Resolution in the visually analysed sections of the reconstructed hot-rod phantom was 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M). Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT+) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60–1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.


2021 ◽  
Author(s):  
Yue Hua Chen ◽  
Ming Ming Yu ◽  
Zhen Guang Wang

Abstract Aim To observe the effect of pHLIP(Var7)-P1AP on the proliferation of MDA-MB-231 triple-negative breast cancer cells and the small-animal single-photon-emission computed tomography (SPECT) imaging of breast cancer–bearing mice carrying MDA-MB-231 cells. Methods Peptide pHLIP(Var7)-P1AP was synthesized by solid-phase peptide synthesis. The binding of fluorescently labeled pHLIP(Var7)-P1AP to MDA-MB-231 cells under various pH conditions and its effect on MDA-MB-231 cell proliferation were analyzed. pHLIP(Var7)-P1AP was labeled with 125I, and the biological distribution of 125I-pHLIP(Var7)-P1AP in the breast cancer mouse model carrying MDA-MB-231 cells as well as the outcome of small-animal SPECT imaging were evaluated. Results pHLIP(Var7)-P1AP was successfully synthesized. Under pH 6.0, fluorescently labeled pHLIP(Var7)-P1AP had a higher binding ability to MDA-MB-231 cells and significantly inhibited the proliferation of MDA-MB-231 cells. The labeling efficiency of pHLIP(Var7)-P1AP with 125I was 33.1 ± 2.7 %, and the radiochemical purity was 98.5 ± 1.8 %. 125I-pHLIP(Var7)-P1AP showed a high concentration in tumors. Small-animal SPECT imaging showed clearly visible tumors at 4 h after injection. Conclusions In the acidic environment, pHLIP(Var7)-P1AP can efficiently target MDA-MB-231 cells and inhibit their growth. Small-animal SPECT of 125I-pHLIP(Var7)-P1AP can clearly image tumors.


2020 ◽  
Author(s):  
Takayuki Shibutani ◽  
Masahisa Onoguchi ◽  
Hiroto Yoneyama ◽  
Takahiro Konishi ◽  
Kenichi Nakajima

Abstract Background A new low-energy high-resolution-sensitivity (LEHRS) collimator was developed by General Electric Healthcare. SwiftScan planar and SPECT system using LEHRS collimator were formulated to achieve the low-dose and/or short-term acquisition. We demonstrated the performance of SwiftScan planar and SPECT system with LEHRS collimator using phantoms. Methods Line source, cylindrical and flat plastic dish phantoms were used to evaluate the performance of planar and SPECT images for four patterns of Siemens LEHR, GE LEHR, GE LEHRS and SwiftScan using two SPECT-CT scanners. Each phantom was filled with 99mTc solution, and the spatial resolution, sensitivity and image uniformity were calculated from the planar and SPECT data. Results The full-width at half maximum (FWHM) values as system spatial resolution of Siemens LEHR, GE LEHR and GE LEHRS were 7.3, 7.5 and 7.3 mm, respectively. GE LEHRS showed the lower FWHM value by increasing the blend ratio in Clarity 2D processing. The system sensitivities of Siemens LEHR, GE LEHR and GE LEHRS were 88.4, 67.6 and 89.8 cps/MBq, respectively. The system sensitivity of GE LEHRS increased by approximately 30% compared with that of GE LEHR and was similar to that of Siemens LEHR. The FWHM values of SPECT with an FBP method were 10.3, 10.4, 10.4 and 10.3 mm (p = n.s.). The FWHM values of the OSEM method were better with an increase in iteration values. The differential uniformities of Siemens LEHR, GE LEHR, GE LEHRS and GE SwiftScan were 15.3%, 15.1%, 15.4% and 14.6%, respectively, using the FBP method. The differential uniformity of OSEM method was higher with an increase in iteration value. Conclusion The SwiftScan planar and SPECT have a high sensitivity while maintaining the spatial resolution compared with the conventional system.


2021 ◽  
Vol 22 (7) ◽  
pp. 3663
Author(s):  
Sara S. Rinne ◽  
Anna Orlova ◽  
Vladimir Tolmachev

The human epidermal growth factor receptor family (EGFR-family, other designations: HER family, RTK Class I) is strongly linked to oncogenic transformation. Its members are frequently overexpressed in cancer and have become attractive targets for cancer therapy. To ensure effective patient care, potential responders to HER-targeted therapy need to be identified. Radionuclide molecular imaging can be a key asset for the detection of overexpression of EGFR-family members. It meets the need for repeatable whole-body assessment of the molecular disease profile, solving problems of heterogeneity and expression alterations over time. Tracer development is a multifactorial process. The optimal tracer design depends on the application and the particular challenges of the molecular target (target expression in tumors, endogenous expression in healthy tissue, accessibility). We have herein summarized the recent preclinical and clinical data on agents for Positron Emission Tomography (PET) and Single Photon Emission Tomography (SPECT) imaging of EGFR-family receptors in oncology. Antibody-based tracers are still extensively investigated. However, their dominance starts to be challenged by a number of tracers based on different classes of targeting proteins. Among these, engineered scaffold proteins (ESP) and single domain antibodies (sdAb) show highly encouraging results in clinical studies marking a noticeable trend towards the use of smaller sized agents for HER imaging.


Sign in / Sign up

Export Citation Format

Share Document