scholarly journals Prototype of a new tip developed to be coupled to dental light-curing units for optimizing bonding of orthodontic brackets and accessories

2013 ◽  
Vol 18 (6) ◽  
pp. 112-116
Author(s):  
Sergio Luiz Mota Júnior ◽  
Márcio José da Silva Campos ◽  
Marco Abdo Gravina ◽  
Marcelo Reis Fraga ◽  
Robert Willer Farinazzo Vitral

OBJECTIVE: development of a new device to be coupled to light-curing units for bonding orthodontic brackets and accessories, and test its efficacy in an in vitro mechanical trial. The inner surface of the device is mirrored and is based on physical concepts of light refraction and reflection. The main advantage of such device is the reduced clinical time needed for bonding and the low possibility of contamination during the process. METHODS: One hundred and twenty specimens were used for testing the shear bond strength of brackets bonded with the device. The Adhesive Remnant Index (ARI) was also determined. The sample was divided into 2 groups. In group 1 a halogen light-curing unit was used while in group 2 a led light-curing unit was used. Each group was then subdivided. In subgroups H1 and L1, a conventional light guide rod was used while in subgroups H2 and L2 bonding was performed with the mirrored device coupled to the tip of the guide light rod. RESULTS: The values obtained for the shear bond strength and the ARI in the subgroups were compared. Results showed that there was no statistically significant difference for the shear strength (p > 0.05) and the ARI (p > 0.05) between the subgroups. CONCLUSION: The tests of mechanical trials and the ARI analysis showed that the new device fulfilled the requirements for bonding orthodontic accessories, and that the time for bonding was reduced to half, being necessary only one light exposure.

2011 ◽  
Vol 22 (3) ◽  
pp. 249-253 ◽  
Author(s):  
Corina Maia de Souza Pinto ◽  
José Tarcísio Lima Ferreira ◽  
Mírian Aiko Nakane Matsumoto ◽  
Maria Cristina Borsatto ◽  
Raquel Assed Bezerra da Silva ◽  
...  

The aim of this study was to assess the influence of different light-emitting diodes (LED) light-curing devices for bonding orthodontic brackets, using the shear bond strength and analysis of adhesive remnant index (ARI). Crowns from 60 bovine incisors received brackets bonded with Transbond XT. Specimens were divided into 4 groups (n=15) according to the light-curing procedures: HL = control, halogen light; OR = Ortholux LED; UL = Ultraled XP, and RD = Radii LED. All light-curing procedures were performed for 40 s. Shear bond strength test was evaluated using an universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by ANOVA and Tukey's test. The ARI scores were evaluated with a stereoscopic magnifying glass and analyzed statistically by Kruskal-Wallis test. A significance level of 5% was set for all analyses. Shear bond strength means in MPa and standard deviations were 9.82 (3.28), 12.70 (3.35), 9.04 (2.80) and 11.22 (2.36) for HL, OR, UL and RD, respectively. OR presented the highest shear bond strength mean value. HL differed significantly (p<0.05) from Groups OR and RD. However, these groups did not differ significantly from each other (p>0.05). Regarding the ARI scores, no statistically significant difference was observed (p>0.05) among the groups. In conclusion, Ortholux LED and Radii LED units provided the highest values of bracket adhesive strength.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Gisele Lima Bezerra ◽  
Carlos Rocha Gomes Torres ◽  
Mateus Rodrigues Tonetto ◽  
Alvaro Henrique Borges ◽  
Milton Carlos Kuga ◽  
...  

The objective of this study is to assess,in vitro, the shear bond strength of orthodontic brackets fixed with remineralizing adhesive systems submitted to thermomechanical cycling, simulating one year of orthodontic treatment. Sixty-four bovine incisor teeth were randomly divided into 4 experimental groups (n=16):XT: Transbond XT,QC: Quick Cure,OL: Ortholite Color, andSEP: Transbond Plus Self-Etching Primer. The samples were submitted to thermomechanical cycling simulating one year of orthodontic treatment. Shear bond strength tests were carried out using a universal testing machine with a load cell of 50 KgF at 0.5 mm/minute. The samples were examined with a stereomicroscope and a scanning electron microscope (SEM) in order to analyze enamel surface and Adhesive Remnant Index (ARI). Kruskal-Wallis and Mann-Whitney (with Bonferroni correction) tests showed a significant difference between the studied groups (p<0.05). Groups XT, QC, and SEP presented the highest values of adhesive resistance and no statistical differences were found between them. The highest frequency of failures between enamel and adhesive was observed in groups XT, QC, and OL. Quick Cure (QC) remineralizing adhesive system presented average adhesive resistance values similar to conventional (XT) and self-etching (SEP) adhesives, while remineralizing system (OL) provided the lowest values of adhesive resistance.


2007 ◽  
Vol 77 (6) ◽  
pp. 1096-1100 ◽  
Author(s):  
Hakan Türkkahraman ◽  
Necdet Adanir

Abstract Objective: To evaluate the effects of potassium nitrate and oxalate desensitizer agents on shear bond strengths of orthodontic brackets. Materials and Methods: Forty-five extracted human premolar teeth were randomly assigned to three groups of 15 each. UltraEZ potassium nitrate desensitizer was applied on teeth in the first group, while BisBlock oxalate desensitizer was applied on teeth in the second group. The third group served as a control. Orthodontic brackets were bonded with a light cure composite resin and cured with a halogen light. After bonding, the shear bond strength of the brackets was tested with a universal testing machine. Results: The highest shear bond strengths were measured in Group III. The shear bond strength in Groups I and II was significantly lower than in Group III (P &lt; .001). Significant difference was also found between Group I and Group II (P &lt; .01). Conclusions: Orthodontic brackets bonded to enamel treated with potassium nitrate and oxalate desensitizers showed significantly lower bond strengths than did brackets bonded to untreated enamel.


Author(s):  
Mohammad Moslem Imani ◽  
Farzaneh Aghajani ◽  
Nafiseh Momeni ◽  
Mohammad Sadegh Ahmad Akhoundi

Objectives: In clinical conditions, orthodontic brackets are exposed to periodic stresses mainly induced by mastication and intraoral forces. The objective of the present study was to evaluate the effects of cyclic loading to simulate masticatory forces on shear bond strength (SBS) of metal brackets bonded to teeth using self-etch and total-etch bonding systems. Materials and Methods: Eighty-four caries- and crack-free bovine mandibular incisors were selected and randomly assigned to two groups based on the type of bonding system. After bonding, all samples were thermocycled (500 cycles) followed by cyclic loading of the half of the specimens in each group by applying 40 N load with 2 Hz frequency for 10,000 cycles. The SBS was measured using a universal testing machine. The adhesive remnant index (ARI) score was calculated subsequently. Data were analyzed using Kolmogorov-Smirnov test, two-way ANOVA and Mann-Whitney test. Results: The SBS was 10.09±3.78 MPa and 14.44±6.06 MPa for self-etch and total-etch bonding systems in cyclic loading group, respectively. The SBS was 9.43±5.3 MPa and 11.31±5.42 MPa in self-etch and total-etch groups without cyclic loading, respectively. Cyclic loading did not cause any significant difference in SBS (P>0.05). The ARI scores of the groups were significantly different (P<0.05). Conclusions: The present results demonstrated that low masticatory forces at 10,000 cycles did not have a significant impact on bracket-adhesive SBS; however, they significantly changed the ARI score. Even though the total-etch bonding system yielded higher SBS than the self-etch system, the performance of both was clinically acceptable.


2012 ◽  
Vol 23 (6) ◽  
pp. 698-702 ◽  
Author(s):  
Gabriela da Rocha Leódido ◽  
Hianna Oliveira Fernandes ◽  
Mateus Rodrigues Tonetto ◽  
Cristina Dupim Presoto ◽  
Matheus Coêlho Bandéca ◽  
...  

The aim of this in vitro study was to evaluate the shear bond strength of brackets after pre-treatment with different fluoride solutions. This study used 48 freshly extracted sound bovine incisors that were randomly assigned to 4 experimental groups (n=12). CG: (control) without treatment; NF: 4 min application of neutral fluoride; APF: application of 1.23% acidulated phosphate fluoride (APF) for 4 min; and SFV: application of 5% sodium fluoride varnish for 6 h. For each group, after surface treatment, prophylaxis of enamel and bracket bonding with Transbond XT composite resin (3M) were performed following the manufacturer's specifications. The shear bond strength was performed with a universal testing machine 24 h after fixing the brackets. The tooth surfaces were analyzed to verify the adhesive remnant index (ARI). Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). There was statistically significant difference among the groups (p<0.0001). CG and NF groups presented significantly higher bond strength than APF and SFV. There was no significant difference between CG and NF or between APF and SFV (p>0.05). The analysis of ARI scores revealed that most failures occurred at the enamel-resin interface. It may be concluded that the pre-treatment of enamel with 1.23% APF and 5% SFV prior to fixing orthodontic brackets reduces shear bond strength values.


2019 ◽  
Vol 45 (1) ◽  
pp. 17-22
Author(s):  
Md Kamal Abdullah ◽  
Tanzila Rafique ◽  
Ashis Kumar Biswas ◽  
Ranjit Ghosh ◽  
Md Abdul Gafur ◽  
...  

Background: Light-cured bonding systems have been widely accepted among orthodontists. Various light curing units are available now. Recently, the light emitting diode (LED) has been introduced alongside halogen light curing units. There is lack of information on the advantages and disadvantages of different light curing systems. The aim of this in vitro study was to compare the shear bond strength of orthodontic brackets and adhesive remnant index (ARI) of an adhesive cured with two different orthodontic light sources i.e. LED and halogen. Methods: Forty four (22 in each group) extracted human premolars without any defects were etched with 37% phosphoric acid and cleansed with water spray and air dried. The sealant (Ortho Solo) was applied on the tooth surface and the brackets were bonded using adhesive (Enlight). Adhesives were cured with Halogen (Litex) and LED (D-LUX) for 40 seconds. Then the specimens were debonded later using a universal testing machine, with crosshead speed of 0.2 mm/min until the brackets were detached. Adhesive remnant index (ARI) scores were assessed under stereomicroscope at ×10 magnification. Results: The shear bond strength in Halogen group was 19.73 ± 3.44 MPa and in the LED group 20.81±3.02 MPa which is little higher than halogen group. The proportion of being adhesive remaining index for ARI Score 1 in Halogen group was 5 (22.7%) and in LED group 7 (31.8%). While ARI Score 2 in the Halogen group was 13 (59.1%) compared to LED group 8 (36.4%). However, ARI Score 3 in Halogen group was 4 (18.2%) and in LED group 7 (31.8%). The overall model showing no significant difference. Conclusion: Within limitations, this in vitro study showed the shear bond strength of orthodontic adhesives cured with a LED was statistically equivalent to those cured with a halogen light curing unit. There were significant differences in the ARI scores of the light-curing units tested. LED light-curing units can be suggested for the polymerization of orthodontic bonding adhesives because it showed a balanced effect on ARI index. Bangladesh Med Res Counc Bull 2019; 45: 17-22


Sign in / Sign up

Export Citation Format

Share Document