STUDY OF THE ACCELERATED COOLING OF A VERY HOT WALL WITH A FORCED FLOW OF SUBCOOLED LIQUID IN FILM BOILING REGIME

Author(s):  
S. Viannay ◽  
J. Karian
1972 ◽  
Vol 22 (4) ◽  
pp. 416-419 ◽  
Author(s):  
�. K. Kalinin ◽  
I. I. Berlin ◽  
V. V. Kostyuk ◽  
Yu. S. Kochelaev ◽  
S. A. Yarkho

Author(s):  
Victor V. Yagov ◽  
Arslan R. Zabirov ◽  
Pavel K. Kanin ◽  
Maxim A. Lexin

Author(s):  
Bambang Joko Suroto ◽  
Masahiro Tashiro ◽  
Sana Hirabayashi ◽  
Sumitomo Hidaka ◽  
Masamichi Kohno ◽  
...  

The effects of hydrophobic circle spot size and subcooling on local film boiling phenomenon from the copper surface with single PTFE (Polytetrafluoroethylene) hydrophobic circle spot at low heat flux has been investigated. The experiments were performed using pure water as the working fluid and subcooling ranging from 0 and 10K. The heat transfer surfaces are used polished copper block with single PTFE hydrophobic circle spot of diameters 2, 4 and 6 mm, respectively. A high-speed camera was used to capture bubble dynamics and disclosed the sequence of the process leading to local film boiling. The result shows that local films boiling occurs on the PTFE circle spot at low heat flux and was triggered by the merging of neighboring bubbles. The study also showed that transition time required for change from nucleate boiling regime to local film boiling regime depends on the diameter of the hydrophobic circle spot and the subcooling. A stable local film boiling occurs at the smallest diameter of hydrophobic spot. Subcooling cause the local film boiling occur at negative superheat and oscillation of bubble dome.