scholarly journals Liquid-phase adsorption of n-hexane on 5A type zeolite. Application of the bidisperse pore model for determination of intraparticle diffusion coefficients.

1991 ◽  
Vol 34 (3) ◽  
pp. 248-254
Author(s):  
Shoji KAGAWA ◽  
Kenji IKEDA
Carbon ◽  
2000 ◽  
Vol 38 (4) ◽  
pp. 573-588 ◽  
Author(s):  
Nasrin R. Khalili ◽  
Minzi Pan ◽  
Giselle Sandı́

2019 ◽  
Vol 70 (11) ◽  
pp. 3903-3907
Author(s):  
Galina Marusic ◽  
Valeriu Panaitescu

The paper deals with the issues related to the pollution of aquatic ecosystems. The influence of turbulence on the transport and dispersion of pollutants in the mentioned systems, as well as the calculation of the turbulent diffusion coefficients are studied. A case study on the determination of turbulent diffusion coefficients for some sectors of the Prut River is presented. A new method is proposed for the determination of the turbulent diffusion coefficients in the pollutant transport equation for specific sectors of a river, according to the associated number of P�clet, calculated for each specific area: the left bank, the right bank and the middle of the river.


2019 ◽  
Vol 20 (5) ◽  
pp. 390-400 ◽  
Author(s):  
Nabil N. AL-Hashimi ◽  
Amjad H. El-Sheikh ◽  
Rania F. Qawariq ◽  
Majed H. Shtaiwi ◽  
Rowan AlEjielat

Background: The efficient analytical method for the analysis of nonsteroidal antiinflammatory drugs (NSAIDs) in a biological fluid is important for determining the toxicological aspects of such long-term used therapies. Methods: In the present work, multi-walled carbon nanotubes reinforced into a hollow fiber by chitosan sol-gel assisted-solid/ liquid phase microextraction (MWCNTs-HF-CA-SPME) method followed by the high-performance liquid chromatography-diode array detection (HPLC–DAD) was developed for the determination of three NSAIDs, ketoprofen, diclofenac, and ibuprofen in human urine samples. MWCNTs with various dimensions were characterized by various analytical techniques. The extraction device was prepared by immobilizing the MWCNTs in the pores of 2.5 cm microtube via chitosan sol-gel assisted technology while the lumen of the microtube was filled with few microliters of 1-octanol with two ends sealed. The extraction device was operated by direct immersion in the sample solution. Results: The main factors influencing the extraction efficiency of the selected NSAIDs have been examined. The method showed good linearity R2 ≥ 0.997 with RSDs from 1.1 to 12.3%. The limits of detection (LODs) were 2.633, 2.035 and 2.386 µg L-1, for ketoprofen, diclofenac, and ibuprofen, respectively. The developed method demonstrated a satisfactory result for the determination of selected drugs in patient urine samples and comparable results against reference methods. Conclusion: The method is simple, sensitive and can be considered as an alternative for clinical laboratory analysis of selected drugs.


Sign in / Sign up

Export Citation Format

Share Document