The effect of water absorption by aggregates on the water/cement ratio of concrete

1959 ◽  
Vol 11 (33) ◽  
pp. 135-142 ◽  
Author(s):  
K. Newman
2013 ◽  
Vol 6 (1) ◽  
pp. 50-61
Author(s):  
Amer M. Ibrahem ◽  
Shakir A. Al-Mishhadani ◽  
Zeinab H.Naji

This investigation aimed to study the effect of nano metakaolin ( NMK ) on some properties (compressive strength ,splitting tensile strength & water absorption ) of concrete. The nano metakaolin (NMK) was prepared by thermal activation of kaolin clay for 2 hours at 750 Ċ. The cement used in this investigation consists of ordinary Portland cement (OPC). The OPC was partially substituted by NMK of ( 3, 5 & 10%) by weight of cement. The C45 concrete was prepared , using water/cement ratio ( W/c) of (0.53) .The Water absorption was tested at 28 days while the tests (compressive strength ,splitting tensile strength) were tested at ages of (7, 28, 60,& 90) days . The compressive strength and splitting tensile strength of concrete with NMK were higher than that of reference concrete with the same W/c ratio.The improvement in the compressive strength when using NMK was (42.2, 55.8 , 63.1% ) at age 28 days for ( 3%, 5%, &10% ) replacement of NMK respectively whereas the improvement in the splitting tensile strength was (0% , 36% & 46.8 %) at age of 28 days when using (3%, 5%, &10% ) NMK respectively. The improvement in the water absorption was (16.6%, 21.79%, &25.6 ) when using (3, 5, &10% )NMK.


2018 ◽  
Vol 30 (3) ◽  
Author(s):  
Chai Teck Jung ◽  
Tang Hing Kwong ◽  
Koh Heng Boon

Abstract: This paper presents some experimental results and discusses the used of recycled foamed aggregates as natural coarse aggregates replacement in producing concrete. The physical properties of recycled foamed aggregates concrete were investigated. The properties studied are water absorption and drying shrinkage from the concrete early ages until the periods of 56 days. The 100 mm x 100 mm cube specimen was used to study the water absorption at the age of 7, 28 and 56 days. Meanwhile, the 100 mm x 100 mm x 300 mm length prism had been casted and used for drying shrinkage test for recycled foamed aggregates concrete. The foamed aggregates was produced from crushing recycled foamed concrete blocks. It were coated with cement paste to reduce its water absorption ability during casting process. Superplasticizer was used to maintain the workability of fresh concrete with a slump vary between 50 mm to 100 mm. The physical tests were conducted on recycled foamed aggregates to determine their initial properties such as loose bulk density, sieve analysis and water absorption rate. Recycled foamed aggregate concretes were produced with varied water cement ratio. The results obtained indicated that the linear elastic relationship between water cement ratio and water absorption rate. The higher the water cement ratio of concrete specimen will obtained higher water absorption rate. Vice versa, the density is low for drying shrinkage. The water absorption decreased while drying shrinkage becomes more stabilized over curing period.


2014 ◽  
Vol 541-542 ◽  
pp. 273-276
Author(s):  
Xiao Nan Dong ◽  
Xi Chen ◽  
Ling Chao Lu ◽  
Shuai Yang

The effects of two admixtures content i.e. water reducer, cellulose ether and water-cement ratio on mechanical strength and dry density of cement-based lightweight thermal insulation board are studied. The result indicates that the water-cement ratio is the important influential factor, which is easier to get good workability. And based on the mechanical strength and dry density, the best range of water reducer content and cellulose ether content are 0.3%-0.6% and 0.4%-0.6% respectively.


Sign in / Sign up

Export Citation Format

Share Document