The Explosion Hazard Classification of Gases and Dusts Relative to Use of Electrical Equipment

1988 ◽  
2021 ◽  
Vol 881 ◽  
pp. 71-76
Author(s):  
Jian Yang ◽  
Hong Bin Li ◽  
Song Tao Ren ◽  
Peng Gang Jin ◽  
Zan Gao

In order to determine the influence of spheroidization process of Ammonium dinitramide’s hazard grade, the hazardous division of Ammonium dinitramide before and after spheroidization is studied by using hazard classification procedure for combustible and explosive substances and articles standard (WJ20405) and hazard classification method and criterion for combusitible and explosive substances and articles standard (WJ20404). The research results show that spheroidization process can significantly improve the temperature stability of Ammonium dinitramide and significantly reduce friction sensitivity and impact sensitivity of Ammonium dinitramide. So spheroidization process can reduce the hazardous of Ammonium dinitramide and improve the safe character of Ammonium dinitramide.


2013 ◽  
Vol 353-356 ◽  
pp. 2277-2280
Author(s):  
Lin Zhi Fu ◽  
Yu Feng Li ◽  
Gang Li

According to the international standard, main problems lying in the process of hazardous zone classification were emphatically analyzed. The source of release was determined in light of its release frequency and duration, namely the continuous source, primary source and secondary source. Considering the effect of release rate, LEL, density, ventilation, obstacles, and meteorological conditions on the classification of the hazardous area, it could be found that the hazardous zone would expand as the release rate increased with lower explosion limit. The gas that was heavier than air covered larger hazardous areas than the lighter gas. Besides, ventilation might speed up the diffusion so as to reduce the scope the hazardous zone; obstacles prevented the diffusion so that concentration of partial gas increased and then the danger level increased; wind at high speed quickened the diffusion to decrease the range of dangerous area. Finally, explosion-proof electrical equipment was selected rationally according to the type of explosive gas and temperature group.


Author(s):  
Abdelkader Abdelmoumene ◽  
Hamid Bentarzi

The identification and classification of electrical faults have a great importance in power system analysis. They help in the dimensioning and the adequate choice of electrical equipment, especially, for protective and interrupting devices. This chapter describes the various faults undergone by the power system and removes some ambiguities causing confusions and difficulties for the correct classification of faults. Once the faults terminologies are well understood and properly assessed; they can be used efficiently to develop enhanced algorithms dedicated to fault detection, classification, isolation and diagnostics.


Sign in / Sign up

Export Citation Format

Share Document