scholarly journals Use of Human Motion Data to Train Wearable Robots

Author(s):  
JIBUM JUNG Et.al

Development of wearable robots is accelerating. Walking robots mimic human behavior and must operate without accidents. Human motion data are needed to train these robots. We developed a system for extracting human motion data and displaying them graphically.We extracted motion data using a Perception Neuron motion capture system and used the Unity engine for the simulation. Several experiments were performed to demonstrate the accuracy of the extracted motion data.Of the various methods used to collect human motion data, markerless motion capture is highly inaccurate, while optical motion capture is very expensive, requiring several high-resolution cameras and a large number of markers. Motion capture using a magnetic field sensor is subject to environmental interference. Therefore, we used an inertial motion capture system. Each movement sequence involved four and was repeated 10 times. The data were stored and standardized. The motions of three individuals were compared to those of a reference person; the similarity exceeded 90% in all cases. Our rehabilitation robot accurately simulated human movements: individually tailored wearable robots could be designed based on our data. Safe and stable robot operation can be verified in advance via simulation. Walking stability can be increased using walking robots trained via machine learning algorithms.

2020 ◽  
pp. 1-8
Author(s):  
Jonathan S. Dufour ◽  
Alexander M. Aurand ◽  
Eric B. Weston ◽  
Christopher N. Haritos ◽  
Reid A. Souchereau ◽  
...  

The objective of this study was to test the feasibility of using a pair of wearable inertial measurement unit (IMU) sensors to accurately capture dynamic joint motion data during simulated occupational conditions. Eleven subjects (5 males and 6 females) performed repetitive neck, low-back, and shoulder motions simulating low- and high-difficulty occupational tasks in a laboratory setting. Kinematics for each of the 3 joints were measured via IMU sensors in addition to a “gold standard” passive marker optical motion capture system. The IMU accuracy was benchmarked relative to the optical motion capture system, and IMU sensitivity to low- and high-difficulty tasks was evaluated. The accuracy of the IMU sensors was found to be very good on average, but significant positional drift was observed in some trials. In addition, IMU measurements were shown to be sensitive to differences in task difficulty in all 3 joints (P < .05). These results demonstrate the feasibility for using wearable IMU sensors to capture kinematic exposures as potential indicators of occupational injury risk. Velocities and accelerations demonstrate the most potential for developing risk metrics since they are sensitive to task difficulty and less sensitive to drift than rotational position measurements.


2012 ◽  
Vol 198-199 ◽  
pp. 1062-1066
Author(s):  
Xu Dong Wu ◽  
Hu Liu ◽  
Song Mo ◽  
Zhe Wu ◽  
Ying Li

Maintainability is a main design attribute of a civil airplane. So evaluation to the maintainability is very important for the design of the civil aircraft. The Human motion capture is a promising technique for maintainability evaluation. In this article, a method about the maintainability evaluation based on the optical motion capture system was presented. Then a test case was developed to demonstrate the feasibility of the method. The test case mainly focused on the accessibility of the civil aircraft.


Sensors ◽  
2021 ◽  
Vol 21 (18) ◽  
pp. 6115
Author(s):  
Przemysław Skurowski ◽  
Magdalena Pawlyta

Optical motion capture is a mature contemporary technique for the acquisition of motion data; alas, it is non-error-free. Due to technical limitations and occlusions of markers, gaps might occur in such recordings. The article reviews various neural network architectures applied to the gap-filling problem in motion capture sequences within the FBM framework providing a representation of body kinematic structure. The results are compared with interpolation and matrix completion methods. We found out that, for longer sequences, simple linear feedforward neural networks can outperform the other, sophisticated architectures, but these outcomes might be affected by the small amount of data availabe for training. We were also able to identify that the acceleration and monotonicity of input sequence are the parameters that have a notable impact on the obtained results.


1999 ◽  
Vol 8 (2) ◽  
pp. 187-203 ◽  
Author(s):  
Tom Molet ◽  
Ronan Boulic ◽  
Daniel Thalmann

Motion-capture techniques are rarely based on orientation measurements for two main reasons: (1) optical motion-capture systems are designed for tracking object position rather than their orientation (which can be deduced from several trackers), (2) known animation techniques, like inverse kinematics or geometric algorithms, require position targets constantly, but orientation inputs only occasionally. We propose a complete human motion-capture technique based essentially on orientation measurements. The position measurement is used only for recovering the global position of the performer. This method allows fast tracking of human gestures for interactive applications as well as high rate recording. Several motion-capture optimizations, including the multijoint technique, improve the posture realism. This work is well suited for magnetic-based systems that rely more on orientation registration (in our environment) than position measurements that necessitate difficult system calibration.


Diagnostics ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 426
Author(s):  
I. Concepción Aranda-Valera ◽  
Antonio Cuesta-Vargas ◽  
Juan L. Garrido-Castro ◽  
Philip V. Gardiner ◽  
Clementina López-Medina ◽  
...  

Portable inertial measurement units (IMUs) are beginning to be used in human motion analysis. These devices can be useful for the evaluation of spinal mobility in individuals with axial spondyloarthritis (axSpA). The objectives of this study were to assess (a) concurrent criterion validity in individuals with axSpA by comparing spinal mobility measured by an IMU sensor-based system vs. optical motion capture as the reference standard; (b) discriminant validity comparing mobility with healthy volunteers; (c) construct validity by comparing mobility results with relevant outcome measures. A total of 70 participants with axSpA and 20 healthy controls were included. Individuals with axSpA completed function and activity questionnaires, and their mobility was measured using conventional metrology for axSpA, an optical motion capture system, and an IMU sensor-based system. The UCOASMI, a metrology index based on measures obtained by motion capture, and the IUCOASMI, the same index using IMU measures, were also calculated. Descriptive and inferential analyses were conducted to show the relationships between outcome measures. There was excellent agreement (ICC > 0.90) between both systems and a significant correlation between the IUCOASMI and conventional metrology (r = 0.91), activity (r = 0.40), function (r = 0.62), quality of life (r = 0.55) and structural change (r = 0.76). This study demonstrates the validity of an IMU system to evaluate spinal mobility in axSpA. These systems are more feasible than optical motion capture systems, and they could be useful in clinical practice.


2011 ◽  
Vol 08 (02) ◽  
pp. 275-299 ◽  
Author(s):  
JUNG-YUP KIM ◽  
YOUNG-SEOG KIM

This paper, describes the development of a motion capture system with novel features for biped robots. In general, motion capture is effectively utilized in the field of computer animation. In the field of humanoid robotics, the number of studies attempting to design human-like gaits by using expensive optical motion capture systems is increasing. The optical motion capture systems used in these studies have involved a large number of cameras because such systems use small-sized ball markers; hence the position accuracy of the markers and the system calibration are very significant. However, since the human walking gait is a simple periodic motion rather than a complex motion, we have developed a specialized motion capture system for this study using dual video cameras and large band-type markers without high-level system calibration in order to capture the human walking gait. In addition to its lower complexity, the proposed capture method requires only a low-cost system and has high space efficiency. An image processing algorithm is also proposed for deriving the human gait data. Finally, we verify the reliability and accuracy of our system by comparing a zero moment point (ZMP) trajectory calculated by the motion captured data with a ZMP trajectory measured by foot force sensors.


2017 ◽  
Vol 2017 (0) ◽  
pp. A-36
Author(s):  
Tatsuro Ishizuka ◽  
Tokio Maeda ◽  
Sakura Yamaji ◽  
Yuji Ohgi ◽  
Humiaki Shibayama ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document