The study of use of toluidine blue as an adjunctive tool to clinical examination in early diagnosis of clinically suspicious oral premalignant and malignant lesions: a study of fifty cases

Author(s):  
Himanshu Chhagan Bayad ◽  
Sanjeev Bhagat ◽  
Dimple Sahni ◽  
Navneet Kaur ◽  
Ravinder Singh ◽  
...  

<p class="abstract"><strong>Background:</strong> Oral carcinoma is among the most prevalent malignancies of head and neck region and is often diagnosed in the advanced stage with significant morbidity and treatment cost. Thus, there is a need for early detection of oral premalignant and malignant lesions. Toluidine blue staining can be used for early detection of these lesions.</p><p class="abstract"><strong>Methods:</strong> The study included 50 patients with clinically suspicious oral premalignant and malignant lesions. These lesions were subjected to toluidine blue staining and biopsy. Diagnoses were confirmed by histopathological examination.  </p><p class="abstract"><strong>Results:</strong> Sensitivity and specificity of toluidine blue for oral premalignant lesions was 92.30% and 80% respectively with the positive predictive value of 92.30%, negative predictive value of 80% and accuracy of 88.88%. Sensitivity and specificity of toluidine blue for oral malignant lesions was 96.30% and 80% respectively with the positive predictive value of 96.30%, negative predictive value of 80% and accuracy of 93.75%.</p><p class="abstract"><strong>Conclusions:</strong> The simplicity of toluidine blue staining and its accuracy suggest that it can be a useful adjunctive tool to diagnosis of oral lesions. Results should be carefully evaluated and correlated with clinical findings and histopathological diagnosis.</p>

Author(s):  
Mona M. Zaky ◽  
Asmaa Hafez ◽  
Marwa M. Zaky ◽  
Ashraf Shoma ◽  
Nermin Y. Soliman ◽  
...  

Abstract Background Benign breast lesions is the most common cause of nipple discharge; however, a rare but major cause is breast cancer. This study assesses the superadded value of MRI in diagnosing causes of pathologic nipple discharge. Ninety-three patients with pathologic nipple discharge were evaluated by sonomammography and DCE-MRI. Sonomammography and MR imaging features were analyzed and correlated with the histopathology. Results Histopathology revealed 69 benign, three high-risk, and 21 malignant lesions. Simply dilated ducts and presence of a mass on US examination as well as non-mass enhancement and STIR signal changes on MRI were of statistically significant probability in differentiation between benign and malignant causes of pathological nipple discharge (p value = 0.017 and 0.001) and (p value ≤ 0.001). Sensitivity and specificity of mammogram and ultrasound in differentiation between benign and malignant causes of pathologic nipple discharge were 71.4% and 54.2% respectively with positive predictive value of 31.2%,negative predictive value of 86.7%, and accuracy of 58.1%. MRI gave higher sensitivity and specificity of 100% and 83.3% with positive predictive value of 63.6%, negative predictive value of 100%, and accuracy of 87.1%. Conclusion Magnetic resonance imaging is superior to sonommagraphy in diagnosis of pathologic nipple discharge and we recommend it in special situations.


Author(s):  
Youssriah Yahia Sabri ◽  
Ikram Hamed Mahmoud ◽  
Lamis Tarek El-Gendy ◽  
Mohamed Raafat Abd El-Mageed ◽  
Sally Fouad Tadros

Abstract Background There are many causes of pleural disease including variable benign and malignant etiologies. DWI is a non-enhanced functional MRI technique that allows qualitative and quantitative characterization of tissues based on their water molecules diffusivity. The aim of this study was to evaluate the diagnostic value of DWI-MRI in detection and characterization of pleural diseases and its capability in differentiating benign from malignant pleural lesions. Results Conventional MRI was able to discriminate benign from malignant lesions by using morphological features (contour and thickness) with sensitivity 89.29%, specificity 76%, positive predictive value 89%, negative predictive value 76.92%, and accuracy 85.37%. ADC value as a quantitative parameter of DWI found that ADC values of malignant pleural diseases were significantly lower than that of benign lesions (P < 0.001). Hence, we discovered that using ADC mean value of 1.68 × 10-3 mm2/s as a cutoff value can differentiate malignant from benign pleural diseases with sensitivity 89.3%, specificity 100%, positive predictive value 100%, negative predictive value 81.2%, and accuracy 92.68% (P < 0.001). Conclusion Although DWI-MRI is unable to differentiate between malignant and benign pleural effusion, its combined morphological and functional information provide valid non-invasive method to accurately characterize pleural soft tissue diseases differentiating benign from malignant lesions with higher specificity and accuracy than conventional MRI.


Author(s):  
Mohamed Zidan ◽  
Shimaa Ali Saad ◽  
Eman Abo Elhamd ◽  
Hosam Eldin Galal ◽  
Reem Elkady

Abstract Background Asymmetric breast density is a potentially perplexing finding; it may be due to normal hormonal variation of the parenchymal pattern and summation artifact or it may indicate an underlying true pathology. The current study aimed to identify the role of diffusion-weighted imaging (DWI) and the apparent diffusion coefficient (ADC) values in the assessment of breast asymmetries. Results Fifty breast lesions were detected corresponding to the mammographic asymmetry. There were 35 (70%) benign lesions and 15 (30%) malignant lesions. The mean ADC value was 1.59 ± 0.4 × 10–3 mm2/s for benign lesions and 0.82 ± 0.3 × 10–3 mm2/s for malignant lesions. The ADC cutoff value to differentiate between benign and malignant lesions was 1.10 × 10–3 mm2/s with sensitivity 80%, specificity 88.6%, positive predictive value 75%, negative predictive value 91%, and accuracy 86%. Best results were achieved by implementation of the combined DCE-MRI and DWI protocol, with sensitivity 93.3%, specificity 94.3%, positive predictive value 87.5%, negative predictive value 97.1%, and accuracy 94%. Conclusion Dynamic contrast-enhanced MRI (DCE-MRI) was the most sensitive method for the detection of the underlying malignant pathology of breast asymmetries. However, it provided a limited specificity that may cause improper final BIRADS classification and may increase the unnecessary invasive procedures. DWI was used as an adjunctive method to DCE-MRI that maintained high sensitivity and increased specificity and the overall diagnostic accuracy of breast MRI examination. Best results can be achieved by the combined protocol of DCE-MRI and DWI.


2018 ◽  
Vol 8 (3) ◽  
pp. 139-142
Author(s):  
Mashah Binte Amin ◽  
Tarana Yasmin ◽  
Khaleda Parvin Rekha ◽  
Rushaida Haque Leeba ◽  
Nasima Akhter ◽  
...  

Background: Fibrocystic breast condition is a common, non-cancerous condition that affects premenopausal woman between 20 and 50 years of age. Because of non-specific nature of clinical presentation, diagnosis is not that easy. Linear array sonography has been helpful for detection of mammary dysplasia.Objective: The purpose of this study was to determine the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of superficial sonography in the diagnosis of chronic cystic mastitis.Materials and Methods: This study was carried out in department of Radiology & Imaging of Enam Medical College and Hospital during June 2013 to October 2017. Sonography was done in 1350 women suspected of having fibrocystic disease. Among them FNAC was done only in 1020 cases. Ultrasonographic findings and histopathological reports were analyzed using SPSS 13.0.Results: According to our study the sensitivity of superficial sonography was 92.4%, specificity 88.8%, positive predictive value 93.8%, negative predictive value 86.4% and accuracy 91% in the diagnosis of fibrocystic changes.Conclusion: With the validity test result, it can be concluded that high frequency sonography provides an accurate diagnosis of fibroadenosis.J Enam Med Col 2018; 8(3): 139-143


2020 ◽  
Vol 7 (1) ◽  
pp. e000355 ◽  
Author(s):  
Rohit Hariharan ◽  
Mark Jenkins

BackgroundCirculating tumour DNA from colorectal cancer (CRC) is a biomarker for early detection of the disease and therefore potentially useful for screening. One such biomarker is the methylated SEPT9 (mSEPT9) gene, which occurs during CRC tumourigenesis. This systematic review and meta-analysis aims to establish the sensitivity, specificity and accuracy of mSEPT9 tests for the early diagnosis of CRC.MethodsA systematic search of the relevant literature was conducted using Medline and Embase databases. Data were extracted from the eligible studies and analysed to estimate pooled sensitivity, specificity and diagnostic test accuracy.ResultsBased on 19 studies, the pooled estimates (and 95% CIs) for mSEPT9 to detect CRC were: sensitivity 69% (62–75); specificity 92% (89–95); positive likelihood ratio 9.1 (6.1–13.8); negative likelihood ratio 0.34 (0.27–0.42); diagnostic OR 27 (15–48) and area under the curve 0.89 (0.86–0.91). The test has a positive predictive value of 2.6% and negative predictive value of 99.9% in an average risk population (0.3% CRC prevalence), and 9.5% (positive predictive value) and 99.6% (negative predictive value) in a high-risk population (1.2% CRC prevalence).ConclusionThe mSEPT9 test has high specificity and moderate sensitivity for CRC and is therefore a potential alternative screening method for those declining faecal immunochemical test for occult blood (FIT) or other screening modalities. However, it is limited by its poor diagnostic performance for precancerous lesions (advanced adenomas and polyps) and its relatively high costs, and little is known about its acceptability to those declining to use the FIT.


2015 ◽  
Vol 51 (5) ◽  
pp. 306-310 ◽  
Author(s):  
Lauren Cunningham ◽  
Audrey Cook ◽  
Andrew Hanzlicek ◽  
Kenneth Harkin ◽  
Joseph Wheat ◽  
...  

The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131–1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4689-4689
Author(s):  
Sriman Swarup ◽  
Somedeb Ball ◽  
Nimesh Adhikari ◽  
Anita Sultan ◽  
Khatrina Swarup ◽  
...  

Introduction: Heparin induced thrombocytopenia (HIT) is a severe prothrombotic condition, usually triggered by exposure to heparin products. It is characterized by platelet activation induced by the formation of antibodies to the platelet factor 4 (PF4)/ heparin polyanion complexes. Diagnostic algorithm includes clinical scoring (4T score) alongside serological test for detection of these antibodies (HIT-Ab), while serotonin release assay (SRA) remains the gold- standard for confirmation. The automated latex immunoturbidometric assay (LIA) has recently been FDA approved as a screening tool for HIT and is a potential alternative to the conventional particle immunofiltration assay (PIFA) for time-sensitive detection of HIT-Ab to guide treatment considerations. We recently introduced LIA in our institution. In this study, we present our experience with LIA in comparison to PIFA in the diagnosis of HIT. Methods: We retrospectively reviewed the charts of all the patients on whom a PIFA was ordered between March 2017 and March 2018 in our hospital. We collected information on the results of the PIFA and SRA (if available). We replaced PIFA with LIA for HIT screening. Then, we introduced a structured protocol for diagnosis of HIT in our institution by incorporating 4T scoring alongside LIA order in the electronic medical record (EMR), in December 2018. We reviewed the EMR of all the patients on whom HIT-Ab test (LIA) was ordered between January and June of 2019, and collected similar information as before. All the data were compiled in a single master excel sheet for calculation of performance characteristics (sensitivity, specificity, positive and negative predictive values) for both PIFA and LIA. A patient was considered to have the diagnosis of HIT if the result of SRA was available and positive. Results: In the first phase, a total of 31 orders for SRA was noted against 170 PIFA orders. Five patients had a positive SRA, of whom two were PIFA negative. Half the patients with a negative SRA result were positive for PIFA. Hence, the sensitivity and specificity of PIFA test for our study population were noted to be 60% and 50%, respectively. PIFA had a positive predictive value (PPV) of mere 18.75% for the diagnosis of HIT, whereas the negative predictive value (NPV) was found to be 86.66%. Introduction of structured protocol for HIT diagnosis substantially reduced the number of inappropriate SRA orders in the second phase. On review of data for six months with the new HIT-Ab test LIA, SRA was ordered in only eight patients, to go with 69 orders for the LIA. The result of LIA was positive in all three patients with a positive SRA, whereas it was false positive in four instances. Only one patient was negative for both LIA and SRA during this period. LIA was found to be 100% sensitive and 20% specific for the diagnosis of HIT in our sample. PPV and NPV for LIA were 42.85% and 100%, respectively. Conclusion: The sensitivity and specificity of LIA were found to be 100% and 20%, respectively, in our study population, which is different from the earlier report (Warkentin et al. 2017). The small sample size is a limitation of our study. Higher PPV and NPV for LIA, with its quick turnaround time, make it a useful alternative for the time-sensitive determination of post-test probability for HIT in patients. [HIT- Ab- Heparin Induced Thrombocytopenia Antibody, PIFA- Particle Immunofiltration Assay, LIA- Latex Immunoturbidometric Assay, SRA- Serotonin Release Assay, +ve- Positive, -ve - Negative, PPV- Positive Predictive Value, NPV- Negative Predictive Value] Disclosures No relevant conflicts of interest to declare.


2015 ◽  
Vol 40 (3) ◽  
pp. 89-91 ◽  
Author(s):  
N Ali ◽  
NC Nath ◽  
R Parvin ◽  
A Rahman ◽  
TM Bhuiyan ◽  
...  

This cross sectional study was carried out in the department of gastroenterology, BIRDEM, Dhaka from January 2010 to May 2011 to determine the role of ascitic fluid ADA and serum CA-125 in the diagnosis of clinically suspected tubercular peritonitis. Total 30 patients (age 39.69±21.26, 18M/12F) with clinical suspicion of tuberculosis peritonitis were included in this study after analyzing selection criteria. Laparoscopic peritoneal biopsy with ‘histopathological diagnosis’ was considered gold standard against which accuracics of two biomarkers (ADA & CA-125) were compared. Cut off value of ADA and CA-125 are 24 u/l, 35 U/ml respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of ADA as a diagnostic modality in tuberculos peritonitis were 87.5%, 83.33%, 95.45%, 62.5% and 86.67% respectively where as CA-125 was found to have 83.33% sensitivity, 50% specificity, 86.9% positive predictive value, 42.85% negative predictive value and 76.6% accuracy. Both biomarkers are simple, non-invasive, rapid and relatively cheap diagnostic test where as laparoscopy is an invasive procedure, costly & requires trained staff and not without risk and also not feasible in all the centre in our country. So ascitic fluid ADA and serum CA-125 are important diagnostic test for peritoneal tuberculosis.Bangladesh Med Res Counc Bull 2014; 40 (3): 89-91


Author(s):  
Dr. Chaturbhuj Prasad Swarnkar ◽  
Dr. Shiv Raj Meena

Background- Rotator cuff tears are one of the most common causes of shoulder pain for which patients seek treatment. As in our daily work, the shoulder joint is the most frequently used, there is higher chance of having shoulder joint injury. The aim of the study is to compare the efficacy of MRI in diagnosing shoulder pathologies in comparison to arthroscopy, considering arthroscopy as the gold standard. Methods- 30 Patient with suspected rotator cuff injury patients, between 18-80 years of age was included in the study. MRI of the shoulder joint was done followed by shoulder arthroscopy. The data collected was analysed for the significant correlation between MRI of shoulder and arthroscopic findings by kappa statistics. Results- The accuracy of MRI in diagnosis of rotator cuff partial tears, was 90%, while sensitivity and specificity was 100.00%, 78.57% and positive predictive value was 84.21% and negative predictive value was 100.00% and accuracy of MRI in diagnosis of rotator cuff full tears, was 86.67%, while sensitivity and specificity was 63.64%, 100.00%) and positive predictive value was 100.00% and negative predictive value was 82.61% in our study. Conclusion- Our study demonstrates a high sensitivity and specificity for the MRI diagnosis of both partial and full thickness rotator cuff tears and good correlation with arthroscopic findings. Keywords: Rotator cuff, Shoulder pain, Arthroscopy, MRI.


Sign in / Sign up

Export Citation Format

Share Document