scholarly journals Treatment initiation or switch to BIC/FTC/TAF – real-world safety and efficacy data from two HIV centers in Romania

GERMS ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 512-522
Author(s):  
Oana Săndulescu ◽  
Mădălina Irimia ◽  
Otilia Elisabeta Benea ◽  
Mariana Mărdărescu ◽  
Liliana Lucia Preoțescu ◽  
...  
2019 ◽  
Vol 14 (10) ◽  
pp. S852
Author(s):  
Y. Ohe ◽  
T. Kato ◽  
W. Shimizu ◽  
K. Sakamoto ◽  
M. Sugeno ◽  
...  

2020 ◽  
Vol 47 (8) ◽  
pp. 834-848 ◽  
Author(s):  
Naoya Yamazaki ◽  
Yoshio Kiyohara ◽  
Hisashi Uhara ◽  
Tetsuya Tsuchida ◽  
Keiko Maruyama ◽  
...  

2021 ◽  
Vol 32 ◽  
pp. S128-S129
Author(s):  
M. Baleiras ◽  
T. Tomás ◽  
J. Mendonça ◽  
T. Padrão ◽  
M. Dinis ◽  
...  

Author(s):  
Mana Kobayashi ◽  
Yutaro Kageyama ◽  
Takashi Ando ◽  
Junko Sakamoto ◽  
Shohji Kimura

Abstract Background Rituximab is conditionally approved in Japan for use in patients with refractory nephrotic syndrome. To meet the conditions of approval, an all-case post-marketing surveillance study was conducted to confirm the real-world safety and efficacy of rituximab in patients of all ages with refractory nephrotic syndrome. Methods All patients scheduled to receive rituximab treatment for refractory nephrotic syndrome were eligible to register (registration: August 29, 2014 through April 15, 2016); the planned observation period was 2 years from the initiation of rituximab treatment (intravenous infusion, 375 mg/m2 once weekly for four doses). The study was conducted at 227 hospitals throughout Japan. Adverse drug reactions (ADRs) were collected for safety outcomes. The efficacy outcomes were relapse-free period and the degree of growth in pediatric (< 15 years) patients. Results In total, 997 (447 pediatric) patients were registered; 981 (445) were included in the safety analysis set; 852 (402) completed the 2-year observation period; and 810 (429) were included in the efficacy analysis set. Refractory nephrotic syndrome had developed in childhood for 85.0% of patients, and 54.6% were aged ≥15 years. ADRs were observed in 527 (53.7%) patients, treatment-related infection/infestation in 235 (24.0%) patients, and infusion reactions in 313 (31.9%) patients. The relapse-free period was 580 days (95% confidence interval, 511–664). There was a significant change in height standard deviation score (pediatric patients; mean change, 0.093; standard deviation, 0.637; P = 0.009). Conclusion The safety and efficacy of rituximab treatment in patients with refractory nephrotic syndrome were confirmed in the real-world setting. Clinical trial registration UMIN000014997.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
D.P Agip Fustamante ◽  
S Ortiz Cruces ◽  
S Camacho Freire ◽  
A Gutierrez Barrios ◽  
A Gomez Menchero ◽  
...  

Abstract Background The AngioSculpt X (Spectranetics) is a novel paclitaxel-coated scoring balloon with encouraging preliminary data for the treatment of in-stent restenosis or de novo complex lesions. Purpose To assess the safety and efficacy of real-world patients with in-stent restenosis (ISR) or de novo complex lesions (vessels &lt;2.5 mm, calcified lesions, bifurcation lesions...) treated with the novel paclitaxel-coated scoring balloon. Methods A “real-world”, prospective registry from two centers was performed including consecutive patients presenting with ISR or de novo complex lesions and treated with AngioSculpt X. Their clinical data were prospectively registered. Major adverse cardiac events (MACE) were defined as a composite of cardiac death, stent thrombosis, nonfatal myocardial infarction, target lesion revascularization (TLR) and target vessel revascularization (TVR). Results Overall, 87 real-world patients and 93 lesions (73% male, 68±10 years, 46% smoker, 83% hypertensive, 62% diabetic, 71% hyperlipidemic, 35% LVEF &lt;60% impairment) were enrolled in the study. Clinical presentation was stable angina in 19%, unstable angina in 33%, NSTEMI in 29% and STEMI in 5%. Radial access account 84%. The median fluoroscopy time was 17 (IQ range 10,0 - 37.5) min. De novo complex lesions were treated in 35% (n=32) while ISR in 63% (n=57), (Prior BMS 19%; Sirolimus DES 9%; Everolimus DES 26%; Biolimus/Anfilimus DES 20%; Zotarolimus DES 26%) with a median time to ISR of 3.6 (IQ range 1.1 - 10.7) years. Total stent length was 28±18 mm, with an overlap spot affected in 18%, and 27% had &gt;1 treatment for ISR. The most frequent artery treated was left anterior descending (41%) followed by left circumflex (35%) and right coronary artery (17%). Quantitative coronary angiography reference diameter of lesions was 2.7±0.5 mm and length 9.0±4.8 mm, with a % stenosis of 75±20. Predilatation/postdilatation was performed in 60/24% respectively. Device diameter was 2.9±0.4 mm and length 13.6±3.9 mm, deployed at 16±3 atmospheres, with an inflation time of 33±16 seconds. The balloon/artery ratio was 0.99±0.03. Crossover was decided on 18 cases (19%) due to remaining intimal flap, but the success rate (residual stenosis &lt;30%) was 100%. Intracoronary imaging technique was performed in 12% (OCT=7, IVUS=4). At 7±6 month follow-up, there were 10 MACE (cardiac death=1, nonfatal myocardial infarction =4, TLR=4 and TVR=1). Conclusions Paclitaxel-coated scoring balloon offers a safe and valuable treatment option for ISR and de novo complex lesions. Funding Acknowledgement Type of funding source: Public hospital(s). Main funding source(s): Juan Ramόn Jiménez University Hospital


Sign in / Sign up

Export Citation Format

Share Document