Field Validation Processes for Multiphase Wet Gas Surface Well Testing Solutions: Example from the Yamburgskoe Arctic Gas Condensate Field, Russia

Author(s):  
Yakov Alexandrovich Shumakov ◽  
Bertrand C. Theuveny ◽  
Igor Alexandrovich Zinchenko
2017 ◽  
pp. 56-61
Author(s):  
M. L. Karnaukhov ◽  
O. N. Pavelyeva

The well testing of gas-condensate horizontal wells are discussed in the article and the comparative analysis of borehole flow capacity, depending on the mode of it’s operation is presented. Extra attention is focused on the issue of timely identification of the reasons for the reduction of fluid withdrawal from the reservoir. The presence of high skin effect is proved, which confirms the existence of low-permeability of bottomhole formation zone related to condensation in the immediate area of the horizontal wellbore.


2018 ◽  
Vol 9 (9) ◽  
pp. 380-386
Author(s):  
Sarah Akintola ◽  
Emmanuel Folorunsho ◽  
Oluwakunle Ogunsakin

Liquid condensation in gas-condensate pipelines in a pronounced phenomenon in long transporting lines because of the composition of the gas which is highly sensitive to variations in temperature and pressure along the length of the pipeline. Hence, there is a resultant liquid accumulation in onshore wet-gas pipelines because of the pipeline profile. This accumulation which is a flow assurance problem can result to pressure loss, slugging and accelerated pipeline corrosion if not properly handled.


2004 ◽  
Author(s):  
D.I. Atkinson ◽  
Ø. Reksten ◽  
G. Smith ◽  
H. Moe
Keyword(s):  

2002 ◽  
Author(s):  
Chris Fair ◽  
Betsy Cook ◽  
Tom Brighton ◽  
Michael Redman ◽  
Stacy Newman
Keyword(s):  
Oil Well ◽  

SPE Journal ◽  
2006 ◽  
Vol 11 (02) ◽  
pp. 199-205 ◽  
Author(s):  
David I. Atkinson ◽  
Oyvind Reksten ◽  
Gerald Smith ◽  
Helge Moe

Summary Dedicated wet-gas flowmeters are now commercially available for the measurement of gas and liquid flow rates and offer a more compact measurement solution than does the traditional separator approach. The interpretation models of traditional multiphase flowmeters emphasize the liquid rate measurements and have been used to well test and meter mostly liquid-rich flow streams. These models were not developed for the measurement of gas flow rates, particularly those of wet gas. A new interpretation is described that allows a traditional multiphase flowmeter to operate in a dual mode either as a multiphase meter or as a wet-gas meter in 90 to 100% gas. The new interpretation model was developed for a commercially available multiphase flowmeter consisting of a venturi and a dual-energy composition meter. This combination results in excellent predictions of the gas flow rate; the liquid rate prediction is made with acceptable accuracy and no additional measurements. The wet gas and low-liquid-volume-fraction interpretation model is described together with the multiphase flowmeter. Examples of applying this model to data collected on flow loops are presented, with comparison to reference flow rates. The data from the Sintef and NEL flow loops show an error (including the reference meter error) in the gas flow rate, better than ± 2% reading (95% confidence interval), at line conditions; the absolute error (including the reference meter error) in the measured total liquid flow rate at line conditions was better than ± 2 m3/h (< ± 300 B/D: 95% confidence interval). This new interpretation model offers a significant advance in the metering of wet-gas multiphase flows and yields the possibility of high accuracies to meet the needs of gas-well testing and production allocation applications without the use of separators. Introduction There has been considerable focus in recent years on the development of new flow-measurement techniques for application to surface well testing and flow-measurement allocation in multiphase conditions without separating the phases. This has resulted in new technology from the industry for both gas and oil production. Today, there are wet-gas flowmeters, dedicated to the metering of wet-gas flows, and multiphase meters, for the metering of multiphase liquid flows. The common approach to wet-gas measurement relates gas and liquid flows to a "pseudo-gas flow rate" calculated from the standard single-phase equations. This addresses the need for gas measurement in the presence of liquids and can be applied to a limit of liquid flow [or gas volume fraction, (GVF)], though the accuracy of this approach decreases with decreasing GVF. The accurate determination of liquid rates by wet-gas meters is restricted in range. The application and performance of multiphase meters has been well documented through technical papers and industry forums, and after several years of development is maturing (Scheers 2004). Some multiphase measurement techniques can perform better, and the meters provide a more compact solution, than the traditional separation approach. It is not surprising that the use of multiphase flowmeters has grown significantly, the worldwide number doubling in little over a 2-year period (Mehdizadeh et al. 2002). Multiphase-flowmeter interpretation emphasizes the liquid rate measurement, and the application of multiphase flowmeters has been predominantly for liquid-rich flow stream allocation and well testing.