scholarly journals Functional Outcomes and Complications of Intramedullary Fixation Devices for Midshaft Clavicle Fractures: A Systematic Review and Meta-Analysis.

2020 ◽  
Author(s):  
Paul Hoogervorst ◽  
Tess van Dam ◽  
Nico Verdonschot ◽  
Gerjon Hannink

Abstract Background An alternative to the current gold standard in operative treatment of displaced midshaft clavicle fractures (DMCF) using plate osteosynthesis, is internal fixation by means of intramedullary fixation devices. These devices differ considerably in their specifications and characteristics. The aim of this systematic review is to generate an overview of functional outcomes and complications in the management of DMCF per available intramedullary device.Methods A systematic review was conducted to identify all papers reporting functional outcomes, union rates and/or complications using an intramedullary fixation device for the management of midshaft clavicle fractures. Multiple databases and trial registries were searched from inception until February 2020. Meta-analysis was conducted based on functional outcomes and type of complication per type of intramedullary fixation device. Pooled estimates of functional outcomes scores and incidence of complications were calculated using a random effects model. Risk of bias and quality was assessed using the Cochrane risk of bias and ROBINS-I tools. The confidence in estimates were rated and described according to the recommendations of the GRADE working group.Results Sixty-seven studies were included in this systematic review. The majority of studies report on the use of Titanium Elastic Nails (TEN). At 12 months follow up the Titanium Elastic Nail and Sonoma CRx report an average Constant-Murley score of 94.4 (95%CI 93-95) and 94.0 (95%CI 92-95) respectively (GRADE High). The most common reported complications after intramedullary fixation are implant-related and implant-specific. For the TEN, hardware irritation and protrusion, telescoping or migration, with a reported pooled incidence 20% (95%CI 14-26) and 12% (95%CI 8-18), are most common (GRADE Moderate). For the Rockwood/Hagie Pin, hardware irritation is identified as the most common complication with 22% (95%CI 13-35) (GRADE Low). The most common complication for the Sonoma CRx was cosmetic dissatisfaction in 6% (95%CI 2-17) of cases (GRADE Very low). Conclusion Although most studies were of low quality, good functional results and union rates irrespective of the type of device are found. However, there are clear device-related and device-specific complications for each. The results of this systematic review and meta-analysis can help guide surgeons in choosing the appropriate operative strategy, implant and informing their patient.

2020 ◽  
Author(s):  
Paul Hoogervorst ◽  
Tess van Dam ◽  
Nico Verdonschot ◽  
Gerjon Hannink

Abstract Background: An alternative to the current gold standard in operative treatment of displaced midshaft clavicle fractures using plate osteosynthesis, is internal fixation by means of an intramedullary fixation device. These devices differ considerably in their specifications and characteristics and an adequate evaluation of their clinical results is warranted.Methods: A systematic review was conducted to identify all papers reporting functional outcomes, union rates and/or complications using an intramedullary fixation device for the management of midshaft clavicle fractures. Multiple databases and trial registries were searched from inception until February 2020. Meta-analysis was conducted based on functional outcomes and type of complication per type of intramedullary fixation device. Pooled estimates of functional outcomes scores and incidence of complications were calculated using a random effects model. Risk of bias and quality was assessed using the Cochrane risk of bias and ROBINS-I tools. The confidence in estimates were rated and described according to the recommendations of the GRADE working group.Results: Sixty-seven studies were included in this systematic review. The majority of studies report on the use of Titanium Elastic Nails (TEN). At 12 months follow up the Titanium Elastic Nail and Sonoma CRx report an average Constant-Murley score of 94.4 (95%CI 93-95) and 94.0 (95%CI 92-95) respectively. The most common reported complications after intramedullary fixation are implant-related and implant-specific. For the TEN, hardware irritation and protrusion, telescoping or migration, with a reported pooled incidence 20% (95%CI 14-26) and 12% (95%CI 8-18), are major contributors to the total complication rate. For the Rockwood/Hagie Pin, hardware irritation is identified as the most common complication with 22% (95%CI 13-35). The most common complication for the Sonoma CRx was cosmetic dissatisfaction in 6% (95%CI 2-17) of cases. Conclusion: Although most studies were of low quality, in general, good functional results and union rates irrespective of the type of device are found in the reviewed literature. However, there are clear device-related and device-specific complications for each. The results of this systematic review and meta-analysis can help guide surgeons in choosing the appropriate operative strategy, implant and informing their patient.Level of Evidence IV


2019 ◽  
Author(s):  
Paul Hoogervorst ◽  
Tess van Dam ◽  
Nico Verdonschot ◽  
Gerjon Hannink

Abstract Background An alternative to the current gold standard in operative treatment of displaced midshaft clavicle fractures using plate osteosynthesis, is internal fixation by means of an intramedullary fixation device. These devices differ considerably in their specifications and characteristics and an adequate evaluation of their clinical results is warranted. Methods A systematic review was conducted to identify all papers reporting functional outcomes, union rates and/or complications using an intramedullary fixation device for the management of midshaft clavicle fractures. Multiple databases were searched from inception until January 2018. Meta-analysis was conducted based on functional outcomes and type of complication per type of intramedullary fixation device. Pooled estimates of functional outcomes scores and incidence of complications were calculated using a random effects model. Results Fifty-eight studies were included in this systematic review. The majority of studies report on the use of Titanium Elastic Nails (TEN). At 12 months follow up the titanium elastic nail and Sonoma CRx report an average Constant-Murley score of 94.2 (96%CI 93.2-95.3) and 93.4 (95%CI 92.1-94.7) respectively. The most common reported complications after intramedullary fixation are implant-related and implant-specific. For the TEN, hardware irritation and protrusion, telescoping or migration, with a reported pooled incidence of 20% (95%CI 14-27) and 13% (95%CI 9-20), are major contributors to the total complication rate. For the Rockwood/Hagie Pin, hardware irritation is identified as the most common complication with 21% (95%CI 11-35). The most common complication for the Sonoma CRx was cosmetic dissatisfaction in 7% (95%CI 2-22) of cases. Conclusion Although most studies were of low quality, in general, good functional results and union rates irrespective of the type of device are found in the reviewed literature. However, there are clear device-related and device-specific complications for each. The results of this systematic review and meta-analysis can help guide surgeons in choosing the appropriate operative strategy, implant and informing their patient.


2020 ◽  
pp. bjsports-2020-102525
Author(s):  
Stefanos Karanasios ◽  
Vasileios Korakakis ◽  
Rod Whiteley ◽  
Ioannis Vasilogeorgis ◽  
Sarah Woodbridge ◽  
...  

ObjectiveTo evaluate the effectiveness of exercise compared with other conservative interventions in the management of lateral elbow tendinopathy (LET) on pain and function.DesignSystematic review and meta-analysis.MethodsWe used the Cochrane risk-of-bias tool 2 for randomised controlled trials (RCTs) to assess risk of bias and the Grading of Recommendations Assessment, Development and Evaluation methodology to grade the certainty of evidence. Self-perceived improvement, pain intensity, pain-free grip strength (PFGS) and elbow disability were used as primary outcome measures.Eligibility criteriaRCTs assessing the effectiveness of exercise alone or as an additive intervention compared with passive interventions, wait-and-see or injections in patients with LET.Results30 RCTs (2123 participants, 5 comparator interventions) were identified. Exercise outperformed (low certainty) corticosteroid injections in all outcomes at all time points except short-term pain reduction. Clinically significant differences were found in PFGS at short-term (mean difference (MD): 12.15, (95% CI) 1.69 to 22.6), mid-term (MD: 22.45, 95% CI 3.63 to 41.3) and long-term follow-up (MD: 18, 95% CI 11.17 to 24.84). Statistically significant differences (very low certainty) for exercise compared with wait-and-see were found only in self-perceived improvement at short-term, pain reduction and elbow disability at short-term and long-term follow-up. Substantial heterogeneity in descriptions of equipment, load, duration and frequency of exercise programmes were evident.ConclusionsLow and very low certainty evidence suggests exercise is effective compared with passive interventions with or without invasive treatment in LET, but the effect is small.PROSPERO registration numberCRD42018082703.


2020 ◽  
Vol 4 (Supplement_1) ◽  
pp. 401-401
Author(s):  
Yue-Heng Yin ◽  
Liu Yat Justina

Abstract Obesity has been shown to intensify the decline of physical function and lead to frailty. Nutrition is an important method in managing obesity and frailty, while seldom reviews have ever explored the effects of nutritional education interventions. We conducted a systematic review (PROSPERO: CRD42019142403) to explore the effectiveness of nutritional education interventions in managing body composition and physio-psychosocial parameters related to frailty. Randomized controlled trials and quasi-experimental studies were searched in CINAHL, Cochrane Library, EMBASE, MEDLINE, PsycINFO, PubMed and Scopus from 2001 to 2019. Hand search for the reference lists of included papers was conducted as well. We assessed the quality of included studies by Cochrane risk of bias tool. Meta-analyses and narrative synthesis were used to analyse the data. Two studies with low risk of bias were screened from 180 articles, which involved 177 older people with an average age of 69.69±4.08 years old. The results showed that nutritional education was significantly effective in reducing body weight and fat mass than exercises, and it was beneficial to enhancing physical function and psychosocial well-being. But the effects of nutritional education in increasing muscle strength were not better than exercises. The combined effects of nutritional education and exercises were superior than either exercises or nutritional education interventions solely in preventing the loss of lean mass and bone marrow density, and in improving physical function. Due to limited numbers of relevant studies, the strong evidence of effectiveness of nutritional education interventions on reversing frailty is still lacking.


BMJ ◽  
2021 ◽  
pp. m4743
Author(s):  
Joshua Z Goldenberg ◽  
Andrew Day ◽  
Grant D Brinkworth ◽  
Junko Sato ◽  
Satoru Yamada ◽  
...  

Abstract Objective To determine the efficacy and safety of low carbohydrate diets (LCDs) and very low carbohydrate diets (VLCDs) for people with type 2 diabetes. Design Systematic review and meta-analysis. Data sources Searches of CENTRAL, Medline, Embase, CINAHL, CAB, and grey literature sources from inception to 25 August 2020. Study selection Randomized clinical trials evaluating LCDs (<130 g/day or <26% of a 2000 kcal/day diet) and VLCDs (<10% calories from carbohydrates) for at least 12 weeks in adults with type 2 diabetes were eligible. Data extraction Primary outcomes were remission of diabetes (HbA 1c <6.5% or fasting glucose <7.0 mmol/L, with or without the use of diabetes medication), weight loss, HbA 1c , fasting glucose, and adverse events. Secondary outcomes included health related quality of life and biochemical laboratory data. All articles and outcomes were independently screened, extracted, and assessed for risk of bias and GRADE certainty of evidence at six and 12 month follow-up. Risk estimates and 95% confidence intervals were calculated using random effects meta-analysis. Outcomes were assessed according to a priori determined minimal important differences to determine clinical importance, and heterogeneity was investigated on the basis of risk of bias and seven a priori subgroups. Any subgroup effects with a statistically significant test of interaction were subjected to a five point credibility checklist. Results Searches identified 14 759 citations yielding 23 trials (1357 participants), and 40.6% of outcomes were judged to be at low risk of bias. At six months, compared with control diets, LCDs achieved higher rates of diabetes remission (defined as HbA 1c <6.5%) (76/133 (57%) v 41/131 (31%); risk difference 0.32, 95% confidence interval 0.17 to 0.47; 8 studies, n=264, I 2 =58%). Conversely, smaller, non-significant effect sizes occurred when a remission definition of HbA 1c <6.5% without medication was used. Subgroup assessments determined as meeting credibility criteria indicated that remission with LCDs markedly decreased in studies that included patients using insulin. At 12 months, data on remission were sparse, ranging from a small effect to a trivial increased risk of diabetes. Large clinically important improvements were seen in weight loss, triglycerides, and insulin sensitivity at six months, which diminished at 12 months. On the basis of subgroup assessments deemed credible, VLCDs were less effective than less restrictive LCDs for weight loss at six months. However, this effect was explained by diet adherence. That is, among highly adherent patients on VLCDs, a clinically important reduction in weight was seen compared with studies with less adherent patients on VLCDs. Participants experienced no significant difference in quality of life at six months but did experience clinically important, but not statistically significant, worsening of quality of life and low density lipoprotein cholesterol at 12 months. Otherwise, no significant or clinically important between group differences were found in terms of adverse events or blood lipids at six and 12 months. Conclusions On the basis of moderate to low certainty evidence, patients adhering to an LCD for six months may experience remission of diabetes without adverse consequences. Limitations include continued debate around what constitutes remission of diabetes, as well as the efficacy, safety, and dietary satisfaction of longer term LCDs. Systematic review registration PROSPERO CRD42020161795.


BMJ Open ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. e042350
Author(s):  
Maximilian Sohn ◽  
Ayman Agha ◽  
Igors Iesalnieks ◽  
Anna Tiefes ◽  
Alfred Hochrein ◽  
...  

IntroductionAcute diverticulitis of the sigmoid colon is increasingly treated by a non-operative approach. The need for colectomy after recovery from a flare of acute diverticulitis of the left colon, complicated diverticular abscess is still controversial. The primary aim of this study is to assess the risk of interval emergency surgery by systematic review and meta-analysis.Methods and analysisThe systematic review and meta-analysis will be conducted in accordance to the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols statement. PubMed/MEDLINE, Cochrane Central Register of Controlled Trials and EMBASE will be screened for the predefined searching term: (Diverticulitis OR Diverticulum) AND (Abscess OR pelvic abscess OR pericolic abscess OR intraabdominal abscess) AND (surgery OR operation OR sigmoidectomy OR drainage OR percutaneous drainage OR conservative therapy OR watchful waiting). All studies published in an English or German-speaking peer-reviewed journal will be suitable for this analysis. Case reports, case series of less than five patients, studies without follow-up information, systematic and non-systematic reviews and meta-analyses will be excluded. Primary endpoint is the rate of interval emergency surgery. Using the Review Manager Software (Review Manager/RevMan, V.5.3, Copenhagen, The Nordic Cochrane Centre, The Cochrane Collaboration, 2012) meta-analysis will be pooled using the Mantel-Haenszel method for random effects. The Risk of Bias in Non-randomized Studies of Interventions tool will be used to assess methodological quality of non-randomised studies. Risk of bias in randomised studies will be assessed using the Cochrane developed RoB 2-tool.Ethics and disseminationAs no new data are being collected, ethical approval is exempt for this study. This systematic review is to provide a new insight on the need for surgical treatment after a first attack of acute diverticulitis, complicated by intra-abdominal or pelvic abscesses. The results of this study will be presented at national and international meetings and published in a peer-reviewed journal.PROSPERO registration numberCRD42020164813.


Sign in / Sign up

Export Citation Format

Share Document