scholarly journals Heat Transfer Performance of Cosine-Shaped Runners

Author(s):  
Ping Huang ◽  
Wei Huang ◽  
Xiajun Lin ◽  
Chi-Min Shu

Abstract To optimize the heat transfer performance of heat exchangers, this study explored the flow properties and heat transfer of cosine-wave-shaped runners with different structural parameters (wave amplitude, focal distance, and circle radius). The effects of the changes in these structural parameters on the flow and temperature fields of specially shaped channels were analyzed. The partial synergy angles of cosine runners were obtained using user-defined programs in CFD software. The synergy of the entire channel was evaluated using the average field synergy angle as an evaluation index. This study investigated the problem of distribution nonuniformity of the temperature differences during the medium flowing process to provide a theoretical foundation and guidelines for optimally designing the structural parameters of specially shaped channels.

2013 ◽  
Vol 832 ◽  
pp. 160-165 ◽  
Author(s):  
Mohammad Alam Khairul ◽  
Rahman Saidur ◽  
Altab Hossain ◽  
Mohammad Abdul Alim ◽  
Islam Mohammed Mahbubul

Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide excellent thermal performance of this type of heat exchangers. In the present study, the effect of different nanofluids on the heat transfer performance in a helically coiled heat exchanger is examined. Four different types of nanofluids CuO/water, Al2O3/water, SiO2/water, and ZnO/water with volume fractions 1 vol.% to 4 vol.% was used throughout this analysis and volume flow rate was remained constant at 3 LPM. Results show that the heat transfer coefficient is high for higher particle volume concentration of CuO/water, Al2O3/water and ZnO/water nanofluids, while the values of the friction factor and pressure drop significantly increase with the increase of nanoparticle volume concentration. On the contrary, low heat transfer coefficient was found in higher concentration of SiO2/water nanofluids. The highest enhancement of heat transfer coefficient and lowest friction factor occurred for CuO/water nanofluids among the four nanofluids. However, highest friction factor and lowest heat transfer coefficient were found for SiO2/water nanofluids. The results reveal that, CuO/water nanofluids indicate significant heat transfer performance for helically coiled heat exchanger systems though this nanofluids exhibits higher pressure drop.


2014 ◽  
Vol 6 ◽  
pp. 147059 ◽  
Author(s):  
Behrouz Takabi ◽  
Saeed Salehi

This paper numerically examines laminar natural convection in a sinusoidal corrugated enclosure with a discrete heat source on the bottom wall, filled by pure water, Al2O3/water nanofluid, and Al2O3-Cu/water hybrid nanofluid which is a new advanced nanofluid with two kinds of nanoparticle materials. The effects of Rayleigh number (103≤Ra≤106) and water, nanofluid, and hybrid nanofluid (in volume concentration of 0% ≤ ϕ ≤ 2%) as the working fluid on temperature fields and heat transfer performance of the enclosure are investigated. The finite volume discretization method is employed to solve the set of governing equations. The results indicate that for all Rayleigh numbers been studied, employing hybrid nanofluid improves the heat transfer rate compared to nanofluid and water, which results in a better cooling performance of the enclosure and lower temperature of the heated surface. The rate of this enhancement is considerably more at higher values of Ra and volume concentrations. Furthermore, by applying the modeling results, two correlations are developed to estimate the average Nusselt number. The results reveal that the modeling data are in very good agreement with the predicted data. The maximum error for nanofluid and hybrid nanofluid was around 11% and 12%, respectively.


Author(s):  
F. Sun ◽  
H. Li ◽  
J. Drummond ◽  
G.-X. Wang

Bayonet tubes, simple refluent heat exchangers, are widely used to heat or cool a media when the heating/cooling agent is readily accessible from one side only. Many studies have been conducted to evaluate the heat transfer performance of bayonet tubes. The majority of these studies focus on the heat transfer in the annular section and little on the end surface. This paper presents a numerical simulation of the laminar flow and heat transfer in a bayonet tube. The simulation is first validated by the experimental data in the literature. The flow and heat transfer in bayonet tubes are then investigated with both flat and curved end surfaces. Both local and average Nusselt number on the end surfaces are calculated under various Re and geometry conditions. Effect of the end surface curvature is studied by comparing the performances of the flat and curved ended bayonet tubes.


Author(s):  
Raffaele L. Amalfi ◽  
Todd Salamon ◽  
Filippo Cataldo ◽  
Jackson B. Marcinichen ◽  
John R. Thome

Abstract The present study is focused on the experimental characterization of two-phase heat transfer performance and pressure drops within an ultra-compact heat exchanger (UCHE) suitable for electronics cooling applications. In this specific work, the UCHE prototype is anticipated to be a critical component for realizing a new passive two-phase cooling technology for high-power server racks, as it is more compact and lighter weight than conventional heat exchangers. This technology makes use of a novel combination of thermosyphon loops, at the server-level and rack-level, to passively cool an entire rack. In the proposed two-phase cooling technology, a smaller form factor UCHE is used to transfer heat from the server-level thermosyphon cooling loop to the rack-level thermosyphon cooling loop, while a larger form factor UCHE is used to reject the total heat from the server rack into the facility-level cooling loop. The UCHE is composed of a double-side-copper finned plate enclosed in a stainless steel enclosure. The geometry of the fins and channels on both sides are optimized to enhance the heat transfer performance and flow stability, while minimizing the pressure drops. These features make the UCHE the ideal component for thermosyphon cooling systems, where low pressure drops are required to achieve high passive flow circulation rates and thus achieve high critical heat flux values. The UCHE’s thermal-hydraulic performance is first evaluated in a pump-driven system at the Laboratory of Heat and Mass Transfer (LTCM-EPFL), where experiments include many configurations and operating conditions. Then, the UCHE is installed and tested as the condenser of a thermosyphon loop that rejects heat to a pumped refrigerant system at Nokia Bell Labs, in which both sides operate with refrigerants in phase change (condensation-to-boiling). Experimental results demonstrate high thermal performance with a maximum heat dissipation density of 5455 (kW/m3/K), which is significantly larger than conventional air-cooled heat exchangers and liquid-cooled small pressing depth brazed plate heat exchangers. Finally, a thermal performance analysis is presented that provides guidelines in terms of heat density dissipations at the server- and rack-level when using passive two-phase cooling.


Author(s):  
Bin Ren ◽  
Xiaoying Tang ◽  
Facai Ren ◽  
Jibing Wang ◽  
Bofeng Bai

Abstract Heat exchanger is a device that transfers heat between hot and cold fluids. Due to the different size and type, the actual heat transfer performance is usually not the same as the design value. Meanwhile, various heat exchangers using new types of heat transfer elements have emerged, bringing the difficulty to obtain the heat transfer performance by only theoretical calculation. Therefore, studying test methods and developing test standards for heat exchangers have become the research focus in many countries. In this paper, the basic principles of various performance test methods are firstly introduced, including Wilson plot method, equal Reynolds number method and nonlinear fitting method. Then the restrictions on the use of these methods and the factors affecting the test results are analyzed. Finally, the Chinese codes and standards of performance testing for heat exchangers are listed, including JB/T 10379-2002, GB/T 27698-2011 and TSG R0010-2019. The test methods used in GB/T 27698 are described in detail. The results show that GB 27698 mainly focus on the specification of testing systems and procedures and can test heat transfer performance of almost all types of heat exchangers in industry under different heat transfer modes. However, there are lack of formulas and methods for calculating uncertainty of testing results.


2019 ◽  
Vol 139 (4) ◽  
pp. 2739-2768 ◽  
Author(s):  
A. Y. Adam ◽  
A. N. Oumer ◽  
G. Najafi ◽  
M. Ishak ◽  
M. Firdaus ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document