The effect of a vertical flow filter bed on a hybrid constructed wetland system

2005 ◽  
Vol 51 (9) ◽  
pp. 137-144 ◽  
Author(s):  
A. Noorvee ◽  
E. Põldvere ◽  
Ü. Mander

Data from 18 sampling wells in Kodijärve horizontal subsurface flow (HSSF) constructed wetland (CW) (South Estonia) is presented and differences in purification efficiencies inside the HSSF CW are calculated. Temporarily anaerobic conditions in the Kodijärve HSSF system did not allow efficient removal of BOD7, NH4-N, Ntot and Ptot. In 2002 a vertical subsurface flow filter was constructed to enhance aeration. The design of the system was based simply on the oxygen demand of the wastewater and on the aeration potential of vertical flow wetlands. The vertical flow system has shown satisfactory results. The purification efficiency of BOD7 in the Kodijärve CW has improved significantly and there has been a slight increase in purification efficiencies of NH4-N and Ntot. On the ohther hand, the removal efficiency of Ptot has decreased significantly. Although, the mass loading rates have increased, mass removal rates of all four parameters have improved significantly. Nevertheless, optimization of the constructed wetland system is essential in order to meet effluent standards during wintertime.

2021 ◽  
Vol 9 ◽  
Author(s):  
Agegnehu Alemu ◽  
Nigus Gabbiye ◽  
Brook Lemma

Tannery wastewater is composed of a complex mixture of organic and inorganic components from various processes that can critically pollute the environment, especially water bodies if discharged without treatment. In this study, integrated vesicular basalt rock and local plant species were used to establish a horizontal subsurface flow constructed wetland system and to investigate the treatment efficiency of tannery wastewater. Four pilot units were vegetated with P. purpureum, T. domingensis, C. latifolius, and E. pyramidalis, and a fifth unit was left unvegetated (control). The constructed wetland units in horizontal subsurface flow systems were effective in removing total chromium (Cr), chemical oxygen demand (COD), and 5-day biological oxygen demand (BOD5) from the inflow tannery wastewater. The removal efficiency reached up to 99.38, 84.03, and 80.32% for total Cr, COD, and BOD5, respectively, in 6 days of hydraulic retention time (HRT). The removal efficiency of total suspended solid (TSS), total phosphorus (TP), and nitrate (NO3−) of the constructed wetland units reached a maximum of 70.59, 62.32, and 71.23%, respectively. This integrated system was effective for treating tannery wastewater, which is below the Ethiopian surface water standard discharge limit set to BOD5 (200 mg L−1), COD (500 mg L−1), total Cr (2 mg L−1), NO3− (20 mg L−1), TSS (50 mg L−1), and TP (10 mg L−1).


2009 ◽  
Vol 60 (8) ◽  
pp. 2001-2007 ◽  
Author(s):  
P. L. Paulo ◽  
L. Begosso ◽  
N. Pansonato ◽  
Roshan R. Shrestha ◽  
M. A. Boncz

Design and configuration for wetlands treating greywater are usually based on literature data obtained from domestic wastewater operating wetlands. It is very important to determine proper criteria for design and configuration to provide efficiency and minimum maintenance, avoiding bad odour and clogging amongst others, ensuring the acceptance of householders. The aim of this work was to design a wetland system treating greywater for a household and determine whether the chosen criteria were appropriate. Some of the criteria taken into consideration for design and configuration were: quantitative and qualitative characteristics, desired removal of biochemical oxygen demand (BOD) and suspended solids (TSS), substrate and ornamental aspect of the system. The system was composed of a grease trap (kitchen), sedimentation tank, a horizontal flow constructed wetland (HF-CW), intermittent feeding system, and a vertical flow constructed wetland (VF-CW). The results showed that the suggested design and configuration were in accordance with the expected efficiency. Being a compact system, it was susceptible to peak flows, temporarily deteriorating the performance of the HF-CW. The hybrid system, however, showed to cope well with influent fluctuations. The overall performance of the system shows that the removal of turbidity, TSS, COD and BOD were over 88%, reaching 95% removal for both BOD and turbidity.


2015 ◽  
Vol 1 (5) ◽  
pp. 235-242
Author(s):  
Édio Damásio da Silva Júnior ◽  
Rogério de Araújo Almeida ◽  
Elisa Rodrigues Siqueira ◽  
Ábio Roduvalho da Silva

2015 ◽  
Vol 71 (7) ◽  
pp. 1088-1096 ◽  
Author(s):  
B. Kim ◽  
M. Gautier ◽  
G. Olvera Palma ◽  
P. Molle ◽  
P. Michel ◽  
...  

The aim of this study was to characterize the efficiency of an intensified process of vertical flow constructed wetland having the following particularities: (i) biological pretreatment by trickling filter, (ii) FeCl3 injection for dissolved phosphorus removal and (iii) succession of different levels of redox conditions along the process line. A pilot-scale set-up designed to simulate a real-scale plant was constructed and operated using real wastewater. The influences of FeCl3 injection and water saturation level within the vertical flow constructed wetland stage on treatment performances were studied. Three different water saturation levels were compared by monitoring: suspended solids (SS), total phosphorus (TP), dissolved chemical oxygen demand (COD), ammonium, nitrate, phosphate, iron, and manganese. The results confirmed the good overall efficiency of the process and the contribution of the trickling filter pretreatment to COD removal and nitrification. The effects of water saturation level and FeCl3 injection on phosphorus removal were evaluated by analysis of the correlations between the variables. Under unsaturated conditions, good nitrification and no denitrification were observed. Under partly saturated conditions, both nitrification and denitrification were obtained, along with a good retention of SSs. Finally, under saturated conditions, the performance was decreased for almost all parameters.


2010 ◽  
Vol 62 (10) ◽  
pp. 2408-2418 ◽  
Author(s):  
C. Y. Wu ◽  
J. K. Liu ◽  
S. H. Cheng ◽  
D. E. Surampalli ◽  
C. W. Chen ◽  
...  

In Taiwan, more than 20% of the major rivers are mildly to heavily polluted by domestic, industrial, and agricultural wastewaters due to the low percentage of sewers connected to wastewater treatment plants. Thus, constructed or engineered wetlands have been adopted as the major alternatives to clean up polluted rivers. Constructed wetlands are also applied as the tertiary wastewater treatment systems for the wastewater polishment to meet water reuse standards with lower operational costs. The studied Kaoping River Rail Bridge Constructed Wetland (KRRBCW) is the largest constructed wetland in Taiwan. It is a multi-function wetland and is used for polluted creek water purification and secondary wastewater polishment before it is discharged into the Kaoping River. Although constructed wetlands are feasible for contaminated water treatment, wetland sediments are usually the sinks for organics and metals. In this study, water and sediment samples were collected from the major wetland basins in KRRBCW. The investigation results show that more than 97% of total coliforms (TC), 55% of biochemical oxygen demand (BOD), and 30% of nutrients [e.g. total nitrogen (TN), total phosphorus (TP)] were removed via the constructed wetland system. However, results from the sediment analyses show that wetland sediments contained high concentrations of metals (e.g. Cu, Fe, Zn, Cr, and Mn), organic contents (sediment oxygen demand = 1.7 to 7.6 g O2/m2 d), and nutrients (up to 18.7 g/kg of TN and 1.22 g/kg of TN). Thus, sediments should be excavated periodically to prevent the release the pollutants into the wetland system and causing the deterioration of wetland water quality. Results of polymerase chain reaction (PCR), denaturing gradient gel electrophoresis (DGGE), and nucleotide sequence analysis reveal that a variation in microbial diversity in the wetland systems was observed. Results from the DGGE analysis indicate that all sediment samples contained significant amounts of microbial ribospecies, which might contribute to the carbon degradation and nitrogen removal. Gradual disappearance of E. coli was also observed along the flow courses through natural attenuation mechanisms.


Author(s):  
Isabela Pires da Silva ◽  
Gabriela Barbosa da Costa ◽  
João Gabriel Thomaz Queluz ◽  
Marcelo Loureiro Garcia

   This study evaluated the effect of hydraulic retention time on chemical oxygen demand (COD) and total nitrogen (TN) removal in an intermittently aerated constructed wetlands. Two horizontal subsurface-flow constructed wetlands were used: one without aeration and the other aerated intermittently (1 hour with aeration/7 hours without aeration). Both systems were evaluated treating domestic wastewater produced synthetically. The flow rate into the two CWs was 8.6 L day-1 having a hydraulic retention time of 3 days. The results show that the intermittently aerated constructed wetland were highly efficient in removing COD (98.25%), TN (83.60%) and total phosphorus (78.10%), while the non-aerated constructed wetland showed lower efficiencies in the removal of COD (93.89%), TN (48.60%) and total phosphorus (58.66). These results indicate, therefore, that intermittent aeration allows the simultaneous occurrence of nitrification and denitrification processes, improving the removal of TN in horizontal subsurface-flow constructed wetlands. In addition, the use of intermittent aeration also improves the performance of constructed wetlands in removing COD and total phosphorus.