Adsorption of methylene blue using modified adsorbents from drinking water treatment sludge

2016 ◽  
Vol 74 (8) ◽  
pp. 1885-1898 ◽  
Author(s):  
M. Nageeb Rashed ◽  
M. A. El-Daim El Taher ◽  
Somaya M. M. Fadlalla

This study aims to explore the preparation and application of alum sludge (AS) and mud sludge (MS) from a drinking water treatment plant to remove methylene blue (MB) dye from aqueous solution. The sludge (MS and AS) was treated by chemical and physical activation to obtain new adsorbents. The adsorption experiments were carried out under different conditions of initial dye concentration (50–100 mg/L) adsorbent dosage (0.05–0.25 g), solution pH (3–9), temperature (20–60 °C) and contact time (20–90 min). Scanning electron microscopy (SEM) and X-ray diffraction instruments were used for characterization of the developed adsorbents. The results show that sludge activated by nitric acid (0.25 M HNO3) and pyrolysis at 700 °C were the best chemically and physically activated adsorbents. The optimum adsorption conditions for the adsorption of MB are 100 ppm initial dye concentration, 1 hour contact time, 250 °C solution temperature, pH 7 and 0.25 g adsorbent dosage. Application of the Langmuir and Freundlich Isotherm models showed that adsorbents fitted the Langmuir model well. SEM studies indicated the porous structural aspects of sludge suitable for removing MB dye.

2019 ◽  
Vol 280 ◽  
pp. 05002 ◽  
Author(s):  
Eko Siswoyo ◽  
Andiny Widya Utari ◽  
Lisa Gustia Norma Mungkari

Laundry activities grow rapidly in Indonesia in the recent year, remaining the problem of environmental pollution because of the use of detergent. The purpose of the current study was to investigate the ability of sludge of drinking water treatment plant (DWTP) as adsorbent combined with phytoremediation system to remove chemical oxygen demand (COD), phosphate and surfactant in laundry wastewater. Batch and continuous blow studies were conducted on different variables such as adsorbent mass, contact time, and type of plant for phytoremediation system. The results of the current study show that adsorption combined phytoremediation system could remove COD, phosphate, and surfactant up to 77.5%, 54.3%, and 99.9%, respectively. Based on the results, it means that the adsorption combined phytoremediation system could be considered as an appropriate environmental technology for laundry wastewater treatment in the near future.


2019 ◽  
Vol 6 (1) ◽  
pp. 53-61 ◽  
Author(s):  
Bahman Masoomi ◽  
Neamatollah Jaafarzadeh ◽  
Tayebeh Tabatabaie ◽  
Esmaeil Kouhgardi ◽  
Sahand Jorfi

Background: Ozone can be used as a single technology or in combination with other processes to improve the coagulation- flocculation or biodegradability in order to remove pollutants in natural water treatment. Methods: In this study, the effects of pre-ozonation with coagulant substances on the quality parameters of drinking water were investigated using humic acid, kaolin, clay, and green algae in a pilot scale. This study was conducted under laboratory conditions (at both acidic and alkaline pH in different dosages of ozone and coagulant at ozone contact time with simulated water sample (5-20 minutes) in different scenarios). Results: The highest removal efficiency of parameters in the state of pre-ozonation alone and preozonation with a coagulant was observed at contact time of 20 minutes, ozone dosage of 5 g/h, coagulant dosage of 25 mg/L, at alkaline pH along with a decrease in temperature. So that, the average removal rate of turbidity, total organic carbon (TOC), color, and chlorophyll a in contact time of 20 minutes was 76.9%, 52.8%, 66.6%, and 85%, respectively. However, compared to ozonation under similar conditions, the reduction in turbidity, TOC, color, and chlorophyll a was 36.13%, 24.4%, 32.13%, and 79.6%, respectively. Also, it was revealed that pre-ozonation with coagulant could effectively improve the removal of parameters. Conclusion: However, since pre-ozonation can be effectively used to improve the coagulation efficacy in the drinking water treatment, the pre-ozonation combined with coagulation is proposed as an alternative to conventional coagulation to improve the process of drinking water treatment plant.


2016 ◽  
Vol 16 (4) ◽  
pp. 922-930 ◽  
Author(s):  
L. Richard ◽  
E. Mayr ◽  
M. Zunabovic ◽  
R. Allabashi ◽  
R. Perfler

The implementation and evaluation of biological nitrification as a possible treatment option for the small-scale drinking water supply of a rural Upper Austrian community was investigated. The drinking water supply of this community (average system input volume: 20 m3/d) is based on the use of deep anaerobic groundwater with a high ammonium content of geogenic origin (up to 5 mg/l) which must be treated to prevent the formation of nitrites in the drinking water supply system. This paper describes the implementation and operation of biological nitrification despite several constraints including space availability, location and financial and manpower resources. A pilot drinking water treatment plant, including biological nitrification implemented in sand filters, was designed and constructed for a maximum treatment capacity of 1.2 m3/h. Online monitoring of selected physicochemical parameters has provided continuous treatment performance data. Treatment performance of the plant was evaluated under standard operation as well as in the case of selected malfunction events.


2017 ◽  
Vol 29 (12) ◽  
pp. 2665-2670
Author(s):  
Soleha Mohamat Yusuff ◽  
K.K. Ong ◽  
W.M.Z. Wan Yunus ◽  
A. Fitrianto ◽  
M. Ahmad ◽  
...  

Author(s):  
Ivone Vaz-Moreira ◽  
Vânia Figueira ◽  
Ana R. Lopes ◽  
Alexandre Lobo-da-Cunha ◽  
Cathrin Spröer ◽  
...  

A Gram-positive, aerobic, non-motile, endospore-forming rod, designated DS22T, was isolated from a drinking-water treatment plant. Cells were catalase- and oxidase-positive. Growth occurred at 15–37 °C, at pH 7–10 and with <8 % (w/v) NaCl (optimum growth: 30 °C, pH 7–8 and 1–3 % NaCl). The major respiratory quinone was menaquinone 7, the G+C content of the genomic DNA was 36.5 mol% and the cell wall contained meso-diaminopimelic acid. On the basis of 16S rRNA gene sequence analysis, strain DS22T was a member of the genus Bacillus. Its closest phylogenetic neighbours were Bacillus horneckiae NRRL B-59162T (98.5 % 16S rRNA gene sequence similarity), Bacillus oceanisediminis H2T (97.9 %), Bacillus infantis SMC 4352-1T (97.4 %), Bacillus firmus IAM 12464T (96.8 %) and Bacillus muralis LMG 20238T (96.8 %). DNA–DNA hybridization, and biochemical and physiological characterization allowed the differentiation of strain DS22T from its closest phylogenetic neighbours. The data supports the proposal of a novel species, Bacillus purgationiresistans sp. nov.; the type strain is DS22T ( = DSM 23494T = NRRL B-59432T = LMG 25783T).


2010 ◽  
Vol 10 (2) ◽  
pp. 121-127 ◽  
Author(s):  
Kim van Schagen ◽  
Luuk Rietveld ◽  
Alex Veersma ◽  
Robert Babuška

The performance of a drinking-water treatment plant is determined by the control of the plant. To design the appropriate control system, a control-design methodology of five design steps is proposed, which takes the treatment process characteristics into account. For each design step, the necessary actions are defined. Using the methodology for the pellet-softening treatment step, a new control scheme for the pellet-softening treatment step has been designed and implemented in the full-scale plant. The implementation resulted in a chemical usage reduction of 15% and reduction in the maintenance effort for this treatment step. Corrective actions of operators are no longer necessary.