scholarly journals Process performance and reuse potential of a decentralized wastewater treatment system

2019 ◽  
Vol 80 (11) ◽  
pp. 2079-2090 ◽  
Author(s):  
Rajiv Ranjan ◽  
Lokendra Kumar ◽  
P. C. Sabumon

Abstract The paper describes briefly the process performance and the reuse potential of a laboratory scale wastewater treatment system. The treatment involves enhanced primary treatment of Vellore Institute of Technology (VIT) campus sewage using ferric chloride as a coagulant, anaerobic digestion of coagulated organics, and biofilm aerobic process. The treated effluent after disinfection (using sunlight and chlorine) was used for irrigation of Tagetes erecta (marigold) plants and the plant growth parameters were evaluated for a life span of 3 months. In the primary treatment, an optimum ferric chloride dose of 30 mg/L could remove turbidity, chemical oxygen demand (COD), biochemical oxygen demand (BOD), and bacterial count (Escherichia coli) of 69%, 60%, 77%, and 55%, respectively. The coagulated organics could digest in a 25 L anaerobic reactor effectively with methane content in biogas varied between 50 and 60% and enhanced volatile suspended solids (VSS) reduction up to 70%. Sunlight based photo-oxidation followed chlorine disinfection saved 50% of the chlorine dose required for disinfection and treated effluent was fit for reuse. The results of growth parameters for Tagetes erecta plants indicate that anaerobically digested sludge is an excellent soil conditioner cum nutrient supplier. The results of this study exhibit a promising reuse potential of a decentralized wastewater treatment system and needs to be promoted for field scale applications.

2019 ◽  
Vol 26 (21) ◽  
pp. 21172-21188 ◽  
Author(s):  
Anju Singh ◽  
Megha Sawant ◽  
Sheetal Jaisingh Kamble ◽  
Mihir Herlekar ◽  
Markus Starkl ◽  
...  

1995 ◽  
Vol 32 (11) ◽  
pp. 1-11 ◽  
Author(s):  
Mohamed F. Hamoda ◽  
Saed M. Al-Awadi

Field sampling and laboratory experimentation were conducted on wastewater effluent generated at a dairy farm in order to characterise the wastewater, evaluate existing primary treatment facilities, and examine an appropriate wastewater treatment system to produce good quality effluents. It has been found that the farm contributes effluents containing considerable loads of organics, solids and nutrient pollutants. Existing treatment facilities which are limited to batch-operated primary settling tanks, are not capable of producing good quality effluent. Experimentation on an aerobic, suspended growth, biological system using sequencing batch reactors (SBR) indicated that the pollutant loads in the primary-treated effluent could be substantially reduced. The study showed that a wastewater treatment system involving primary settling tanks combined with additional aerobic biological treatment is capable of removing about 94% COD and 96% SS from the farm effluents. This system could be easily integrated and coordinated with existing facilities. A wastewater management scheme has been proposed to include waste minimisation, waste treatment and effluent reuse in irrigation.


Sign in / Sign up

Export Citation Format

Share Document