Sealing ability of materials used as protective cervical barrier in internal tooth bleaching

RSBO ◽  
2017 ◽  
Vol 1 (2) ◽  
pp. 67
Author(s):  
Juan Fernando Ordoñéz-Aguilera ◽  
Rafael Massunari Maenosono ◽  
Denise Ferracioli Oda ◽  
Heitor Marques Honório ◽  
Rafael Francisco Lia Mondelli ◽  
...  

The use of a protective cervical barrier (PCB) is very well established to perform a safe internal bleaching; however, there is still no consensus on which material has the best sealing ability. Objective: This in vitro study aimed to evaluate the apical and linear sealing of different PCB materials placed during internalbleaching. Material and methods: This study had two study factors: PCB positioning, divided at two levels (cement-enamel junction [CEJ] and 1mm above the cement enamel junction [CEJ+1]); and PCB material, divided at eight levels (resin composite [RC], glass ionomer cement [GIC], resin-modified glass ionomer cement liner [LRGIC], restorative resin-modified glass ionomer cement [RRGIC], zinc phosphate cement [ZPC], eugenol-free zinc oxide cement [ZOC],provisional filling resin [PFR] and gutta-percha as control [GUT]). Response variables were apical and linear sealing obtained through dye penetration and analyzed with a digital microscope. Data were subjected to two-way analysis of variance followed by Tukey test (p<0.05). Results: The main factor for both apical and linear sealing was the type of material (p<0.01), regardless of their position. RC and ZPC presented the worst sealing values (p<0.05). The Spearmanrank correlation coefficient revealed a positive correlation between the apical and linear leakage. Conclusion: The results suggest that RC and ZPC must be avoided as a PCB during internal bleaching procedures.

RSBO ◽  
2017 ◽  
Vol 14 (2) ◽  
pp. 67-73
Author(s):  
Juan Fernando Ordoñéz-Aguilera ◽  
Rafael Massunari Maenosono ◽  
Denise Ferracioli Oda ◽  
Heitor Marques Honório ◽  
Rafael Francisco Lia Mondelli ◽  
...  

The use of a protective cervical barrier (PCB) is very well established to perform a safe internal bleaching; however, there is still no consensus on which material has the best sealing ability. Objective: This in vitro study aimed to evaluate the apical and linear sealing of different PCB materials placed during internal bleaching. Material and methods: This study had two study factors: PCB positioning, divided at two levels (cement-enamel junction [CEJ] and 1mm above the cement enamel junction [CEJ+1]); and PCB material, divided at eight levels (resin composite [RC], glass ionomer cement [GIC], resin-modified glass ionomer cement liner [LRGIC], restorative resin-modified glass ionomer cement [RRGIC], zinc phosphate cement [ZPC], eugenol-free zinc oxide cement [ZOC], provisional filling resin [PFR] and gutta-percha as control [GUT]). Response variables were apical and linear sealing obtained through dye penetration and analyzed with a digital microscope. Data were subjected to two-way analysis of variance followed by Tukey test (p<0.05). Results: The main factor for both apical and linear sealing was the type of material (p<0.01) regardless of their position. RC and ZPC presented the worst sealing values (p<0.05). The Spearman rank correlation coefficient revealed a positive correlation between the apical and linear leakage. Conclusion: The results suggest that RC and ZPC must be avoided as a PCB during internal bleaching procedures.


Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1700
Author(s):  
Atsushi Kameyama ◽  
Aoi Saito ◽  
Akiko Haruyama ◽  
Tomoaki Komada ◽  
Setsuko Sugiyama ◽  
...  

This study aimed to examine the marginal seal between various commercial temporary restorative materials and exposed dentin/built-up composite. Sixty bovine incisors were cut above the cemento-enamel junction, and half of the dentin was removed to form a step, which was built up using flowable resin composite. The root canals were irrigated, filled with calcium hydroxide, and sealed using one of six temporary sealing materials (hydraulic temporary restorative material, temporary stopping material, zinc oxide eugenol cement, glass-ionomer cement, auto-cured resin-based temporary restorative material, and light-cured resin-based temporary restorative material) (n = 10 for each material). The samples were thermocycled 500 times and immersed in an aqueous solution of methylene blue. After 2 days, they were cut along the long axis of the tooth and the depth of dye penetration was measured at the dentin side and the built-up composite side. For the margins of the pre-endodontic resin composite build-up, the two resin-based temporary restorative materials showed excellent sealing. Hydraulic temporary restorative material had a moderate sealing effect, but the sealing effect of both zinc oxide eugenol cement and glass-ionomer cement was poorer.


2013 ◽  
Vol 37 (4) ◽  
pp. 403-406 ◽  
Author(s):  
S Tamilselvam ◽  
MJ Divyanand ◽  
P Neelakantan

Objective: This aim of this study was at compare the fibroblast cytotoxicicty of four restorative materials - a conventional glass ionomer cement (GC Fuji Type II GIC), a ceramic reinforced glass ionomer cement (Amalgomer), a giomer (Beautifil II) and a resin composite (Filtek Z350) at three different time periods (24, 48 and 72 hours). Method: The succinyl dehydrogenase (MTT) assay was employed. Cylindrical specimens of each material (n=15) were prepared and stored in Dulbecco's modified Eagle medium, following which L929 fibroblasts were cultured in 96 well plates. After 24 hours of incubation, the MTT assay was performed to detect the cell viability. The method was repeated after 48 and 72 hours. The impact of materials and exposure times on cytotoxicity of fibroblasts was statistically analyzed using two way ANOVA (P=0.05). Results: Both time and material had an impact on cell viability, with giomer demonstrating the maximum cell viability at all time periods. The cell viability in the giomer group was significantly different from all other materials at 24 and 72 hours (P&lt;0.05), while at 48 hours giomer was significantly different only with resin composite (P&lt;0.05). Conclusions: Giomers showed better biocompatibility than conventional and ceramic reinforced glass ionomer cements and, resin composite. Ceramic reinforced glass ionomer demonstrated superior biocompatibility compared to conventional glass ionomer.


2016 ◽  
Vol 41 (2) ◽  
pp. 208-218 ◽  
Author(s):  
KV Nguyen ◽  
RH Wong ◽  
J Palamara ◽  
MF Burrow

SUMMARY Objectives: This study investigated cuspal deformation in teeth restored with different types of adhesive materials with and without a base. Methods: Mesio-occluso-distal slot cavities of moderately large dimension were prepared on extracted maxillary premolars (n=24). Teeth were assigned to one of four groups and restored with either a sonic-activated bulk-fill resin composite (RC) (SonicFill), or a conventional nanohybrid RC (Herculite Ultra). The base materials used were a flowable nanofilled RC (Premise Flowable) and a high-viscosity resin-modified glass-ionomer cement (RMGIC) (Riva Light-Cure HV). Cuspal deflection was measured with two direct current differential transformers, each contacting a buccal and palatal cusp. Cuspal movements were recorded during and after restoration placement. Data for the buccal and palatal cusp deflections were combined to give the net cuspal deflection. Results: Data varied widely. All teeth experienced net inward cuspal movement. No statistically significant differences in cuspal deflection were found among the four test groups. Conclusions: The use of a flowable RC or an RMGIC in closed-laminate restorations produced the same degree of cuspal movement as restorations filled with only a conventional nanohybrid or bulk-fill RC.


Author(s):  
AlSarheed M ◽  
Salama F

Background: The purpose of this in vitro study was to evaluate the effect of finishing/polishing procedures on color stability of three restorative materials: Nano-hybrid resin composite (NRC), silver glass ionomer cement (SGI), and resin-modified glass ionomer cement (RMGI) exposed to different staining of energy drinks: Barbican, Bison, and Red bull.


Sign in / Sign up

Export Citation Format

Share Document