scholarly journals A Combination Method for Electrocardiogram Rejection from Surface Electromyogram

2014 ◽  
Vol 8 (1) ◽  
pp. 13-19 ◽  
Author(s):  
Sara Abbaspour ◽  
Ali Fallah

The electrocardiogram signal which represents the electrical activity of the heart provides interference in the recording of the electromyogram signal, when the electromyogram signal is recorded from muscles close to the heart. Therefore, due to impurities, electromyogram signals recorded from this area cannot be used. In this paper, a new method was developed using a combination of artificial neural network and wavelet transform approaches, to eliminate the electrocardiogram artifact from electromyogram signals and improve results. For this purpose, contaminated signal is initially cleaned using the neural network. With this process, a large amount of noise can be removed. However, low-frequency noise components remain in the signal that can be removed using wavelet. Finally, the result of the proposed method is compared with other methods that were used in different papers to remove electrocardiogram from electromyogram. In this paper in order to compare methods, qualitative and quantitative criteria such as signal to noise ratio, relative error, power spectrum density and coherence have been investigated for evaluation and comparison. The results of signal to noise ratio and relative error are equal to 15.6015 and 0.0139, respectively.

Geophysics ◽  
1964 ◽  
Vol 29 (5) ◽  
pp. 806-813 ◽  
Author(s):  
J. G. Hagedoorn

In first‐arrival refraction work, the initial deflection of the first loop of the signal arriving from the shotpoint must be readily recognised against a background of seismic disturbances due to sources other than the explosion. The accuracy of timing a first arrival is determined by this signal‐to‐noise ratio. It depends primarily on the location of shot and receivers, the size of the charge, and the existing ground unrest at the time of registration. Experiments carried out with these variables kept constant, by recording at the same location from the same shot, show how much the signal‐to‐noise ratio also depends on the characteristics of the recording equipment used. The best signal‐to‐noise ratio is certainly not obtained when the transmission curve of the entire system, comprising geophone, amplifier, and galvanometer, peaks at the apparent dominant frequency of the refraction signal. Practical examples show that the signal‐to‐noise ratio can be improved considerably by using recording systems that transmit a band of frequencies extending many octaves below the observed dominant frequency. The inception of an oscillatory signal was found to be particularly sensitive to the characteristics of a recording system. A seismometer, for example, will transform a starting sine wave with a frequency equal to the natural frequency of the seismometer into a signal with a first loop that is about half as high and half as long as the succeeding loops, the latter moreover being advanced by one‐quarter period. This relative constriction of the initial part of a signal is called the “cramping” effect. Such an effect will weaken a refraction first arrival relative to simultaneously arriving later parts of noise signals. This explains why a cramping effect will impair the signal‐to‐noise ratio. A cramping effect can, of course, be avoided by using a recording system with a flat frequency response. The opposite effect, which can be expected to improve the signal‐to‐noise ratio, could obviously be achieved by using systems with relatively increased low‐frequency response. The practical limit to this improvement would be set by the low‐frequency noise that is enhanced by this procedure.


Author(s):  
Navaamsini Boopalan ◽  
Agileswari K. Ramasamy ◽  
Farrukh Hafiz Nagi

Array sensors are widely used in various fields such as radar, wireless communications, autonomous vehicle applications, medical imaging, and astronomical observations fault diagnosis. Array signal processing is accomplished with a beam pattern which is produced by the signal's amplitude and phase at each element of array. The beam pattern can get rigorously distorted in case of failure of array element and effect its Signal to Noise Ratio (SNR) badly. This paper proposes on a Hybrid Neural Network layer weight Goal Attain Optimization (HNNGAO) method to generate a recovery beam pattern which closely resembles the original beam pattern with remaining elements in the array. The proposed HNNGAO method is compared with classic synthesize beam pattern goal attain method and failed beam pattern generated in MATLAB environment. The results obtained proves that the proposed HNNGAO method gives better SNR ratio with remaining working element in linear array compared to classic goal attain method alone. Keywords: Backpropagation; Feed-forward neural network; Goal attain; Neural networks; Radiation pattern; Sensor arrays; Sensor failure; Signal-to-Noise Ratio (SNR)


2021 ◽  
Author(s):  
S.V. Zimina

Setting up artificial neural networks using iterative algorithms is accompanied by fluctuations in weight coefficients. When an artificial neural network solves the problem of allocating a useful signal against the background of interference, fluctuations in the weight vector lead to a deterioration of the useful signal allocated by the network and, in particular, losses in the output signal-to-noise ratio. The goal of the research is to perform a statistical analysis of an artificial neural network, that includes analysis of losses in the output signal-to-noise ratio associated with fluctuations in the weight coefficients of an artificial neural network. We considered artificial neural networks that are configured using discrete gradient, fast recurrent algorithms with restrictions, and the Hebb algorithm. It is shown that fluctuations lead to losses in the output signal/noise ratio, the level of which depends on the type of algorithm under consideration and the speed of setting up an artificial neural network. Taking into account the fluctuations of the weight vector in the analysis of the output signal-to-noise ratio allows us to correlate the permissible level of loss in the output signal-to-noise ratio and the speed of network configuration corresponding to this level when working with an artificial neural network.


2012 ◽  
Vol 108 (10) ◽  
pp. 2837-2845 ◽  
Author(s):  
Go Ashida ◽  
Kazuo Funabiki ◽  
Paula T. Kuokkanen ◽  
Richard Kempter ◽  
Catherine E. Carr

Owls use interaural time differences (ITDs) to locate a sound source. They compute ITD in a specialized neural circuit that consists of axonal delay lines from the cochlear nucleus magnocellularis (NM) and coincidence detectors in the nucleus laminaris (NL). Recent physiological recordings have shown that tonal stimuli induce oscillatory membrane potentials in NL neurons (Funabiki K, Ashida G, Konishi M. J Neurosci 31: 15245–15256, 2011). The amplitude of these oscillations varies with ITD and is strongly correlated to the firing rate. The oscillation, termed the sound analog potential, has the same frequency as the stimulus tone and is presumed to originate from phase-locked synaptic inputs from NM fibers. To investigate how these oscillatory membrane potentials are generated, we applied recently developed signal-to-noise ratio (SNR) analysis techniques (Kuokkanen PT, Wagner H, Ashida G, Carr CE, Kempter R. J Neurophysiol 104: 2274–2290, 2010) to the intracellular waveforms obtained in vivo. Our theoretical prediction of the band-limited SNRs agreed with experimental data for mid- to high-frequency (>2 kHz) NL neurons. For low-frequency (≤2 kHz) NL neurons, however, measured SNRs were lower than theoretical predictions. These results suggest that the number of independent NM fibers converging onto each NL neuron and/or the population-averaged degree of phase-locking of the NM fibers could be significantly smaller in the low-frequency NL region than estimated for higher best-frequency NL.


2020 ◽  
Author(s):  
chaofeng lan ◽  
yuanyuan Zhang ◽  
hongyun Zhao

Abstract This paper draws on the training method of Recurrent Neural Network (RNN), By increasing the number of hidden layers of RNN and changing the layer activation function from traditional Sigmoid to Leaky ReLU on the input layer, the first group and the last set of data are zero-padded to enhance the effective utilization of data such that the improved reduction model of Denoise Recurrent Neural Network (DRNN) with high calculation speed and good convergence is constructed to solve the problem of low speaker recognition rate in noisy environment. According to this model, the random semantic speech signal with a sampling rate of 16 kHz and a duration of 5 seconds in the speech library is studied. The experimental settings of the signal-to-noise ratios are − 10dB, -5dB, 0dB, 5dB, 10dB, 15dB, 20dB, 25dB. In the noisy environment, the improved model is used to denoise the Mel Frequency Cepstral Coefficients (MFCC) and the Gammatone Frequency Cepstral Coefficents (GFCC), impact of the traditional model and the improved model on the speech recognition rate is analyzed. The research shows that the improved model can effectively eliminate the noise of the feature parameters and improve the speech recognition rate. When the signal-to-noise ratio is low, the speaker recognition rate can be more obvious. Furthermore, when the signal-to-noise ratio is 0dB, the speaker recognition rate of people is increased by 40%, which can be 85% improved compared with the traditional speech model. On the other hand, with the increase in the signal-to-noise ratio, the recognition rate is gradually increased. When the signal-to-noise ratio is 15dB, the recognition rate of speakers is 93%.


2019 ◽  
Vol 146 (4) ◽  
pp. 2961-2962
Author(s):  
Kira Howarth ◽  
David F. Van Komen ◽  
Tracianne B. Neilsen ◽  
David P. Knobles ◽  
Peter H. Dahl ◽  
...  

Sensors ◽  
2020 ◽  
Vol 20 (19) ◽  
pp. 5704
Author(s):  
Zhenhu Jin ◽  
Yupeng Wang ◽  
Kosuke Fujiwara ◽  
Mikihiko Oogane ◽  
Yasuo Ando

Thanks to their high magnetoresistance and integration capability, magnetic tunnel junction-based magnetoresistive sensors are widely utilized to detect weak, low-frequency magnetic fields in a variety of applications. The low detectivity of MTJs is necessary to obtain a high signal-to-noise ratio when detecting small variations in magnetic fields. We fabricated serial MTJ-based sensors with various junction area and free-layer electrode aspect ratios. Our investigation showed that their sensitivity and noise power are affected by the MTJ geometry due to the variation in the magnetic shape anisotropy. Their MR curves demonstrated a decrease in sensitivity with an increase in the aspect ratio of the free-layer electrode, and their noise properties showed that MTJs with larger junction areas exhibit lower noise spectral density in the low-frequency region. All of the sensors were able detect a small AC magnetic field (Hrms = 0.3 Oe at 23 Hz). Among the MTJ sensors we examined, the sensor with a square-free layer and large junction area exhibited a high signal-to-noise ratio (4792 ± 646). These results suggest that MTJ geometrical characteristics play a critical role in enhancing the detectivity of MTJ-based sensors.


Sign in / Sign up

Export Citation Format

Share Document