scholarly journals Comparative study of water quality parameters of lake water (Chinna Eri) with surrounding bore well water samples, Thuraiyur (Tk), Tiruchirappalli (Dt), Tamil Nadu.

Author(s):  
Sudha, R ◽  
◽  
Sangeetha, T ◽  
2015 ◽  
Vol 8 (1) ◽  
pp. 85-89
Author(s):  
F Zannat ◽  
MA Ali ◽  
MA Sattar

A study was conducted to evaluate the water quality parameters of pond water at Mymensingh Urban region. The water samples were collected from 30 ponds located at Mymensingh Urban Region during August to October 2010. The chemical analyses of water samples included pH, EC, Na, K, Ca, S, Mn and As were done by standard methods. The chemical properties in pond water were found pH 6.68 to 7.14, EC 227 to 700 ?Scm-1, Na 15.57 to 36.00 ppm, K 3.83 to 16.16 ppm, Ca 2.01 to 7.29 ppm, S 1.61 to 4.67 ppm, Mn 0.33 to 0.684 ppm and As 0.0011 to 0.0059 ppm. The pH values of water samples revealed that water samples were acidic to slightly alkaline in nature. The EC value revealed that water samples were medium salinity except one sample and also good for irrigation. According to drinking water standard Mn toxicity was detected in pond water. Considering Na, Ca and S ions pond water was safe for irrigation and aquaculture. In case of K ion, all the samples were suitable for irrigation but unsuitable for aquaculture.J. Environ. Sci. & Natural Resources, 8(1): 85-89 2015


he water quality analysis is an important aspect in understanding the behavior of water and what can they be used for. This study gives us a valuable information on the general properties of water quality parameters like pH, electrical conductivity, TDS, Bicarbonate, Sulfate, Nitrate, chloride etc. of the study area . Water samples were analyzed at the water quality lab. NIH, Roorkee for pH, electrical conductivity and total dissolved solids. The pH of water varied from 7.14 to 7.75. The electrical conductivity (EC) of sample falls from 620µS/cm to 2000µS/cm. The overall total dissolved solids in water of study area varied from 120mg/l to 900mg/l. Overall the range of the Chloride in water of the study area tend to falls between 13mg/l to 375mg/l. Sulfate of all the water samples that were collected from the study area have ranged from 28mg/l to 250mg .The range of the Bicarbonate of all the water samples varied from 320mg/l to 1051mg/l. The study area helps to know about water quality parameters and how to find their values by usingtwo methods : 1) titration method 2) instrumental method .It also helps us to apply these water quality parameters in ArcGis. It helps us to show the values of different parameters in different blocks ofambala for different years In this we have studied different blocks of ambala district Haryana .We have taken the samples from different places from the blocks and also samples are from wells, canal , rivers, ponds.


2021 ◽  
Vol 3 (1) ◽  
pp. 1-6
Author(s):  
O. A. Babalola ◽  
◽  
F. A. Fakunmoju ◽  
T. F. Sunnuvu ◽  
B. E. Faleti ◽  
...  

Comparative study on African catfish hypophysation indices using ovaprim and chicken pituitary gland extract (CPGE) was carried out. Sixteen (16) African catfish brood stocks between 1100 and 2300 g in ratio 2:1 and four (4) numbers of layer birds (Gallus gallus domesticus) between 1200 and 2200 g in ratio 1:3 were used respectively. The experiment was batched into “A” and “B”. Batch ‘A’ was placed on ovaprim while batch ‘B’ was placed on CPGE. An indoor hatchery vat, measuring 0.6096 m x 1.8288 m x 0.3048 m each was used for the incubation. Digital measuring kits were used to monitor water quality parameters and measurement of the brood stocks weights independently. Brood stocks on ovaprim and CPGE treatments had the following mean hypophysation indices in these order: fecundity (11100±7690 and 17760±13863), latency period (9.53±0.54 and 9.77±0.49), fertilization percentage (94.03±5.90% and 90.6±10.11%), hatchability percentage (75.6±0.81% and79.35±10.27%), number of eggs produced (5889±657.37 and 9403.33±589.80), total number of larvae hatched (4717.33±1111.0 and 7111.33±506.64), SGR (0.67±0.31 and 1.1±0.31), and survival rate (64.81±0.71 and66.24±2.19) respectively. There was no significant difference (p = 0.05) in the mean values of fecundity, latency period, fertilization and hatchability percentages in both treatments but there was significant difference (p ≤ 0.05) in number of eggs produced and total number of larvae hatched in both treatments. The water quality parameters were within the range for induced breeding techniques and there was no significant difference (p= 0.05) in both experiments. Both ovaprim and CPGE had excellent results from the induced breeding of Clarias gariepinus and yielded good results. Therefore, CPGE could be recommended from the view point of excellent results and its availability from chicken slaughter houses as against ovaprim which are imported.


2006 ◽  
Vol 6 (10) ◽  
pp. 2193-2200 ◽  
Author(s):  
Hossain K.M. Delowar ◽  
Imtiaz Uddin . ◽  
W.H. Abou EL Hassan . ◽  
Mst. Farida Perveen . ◽  
M. Irshad . ◽  
...  

2017 ◽  
Vol 9 (2) ◽  
pp. 97-104
Author(s):  
MMM Hoque ◽  
PP Deb

This study was conducted to know the status of physicochemical water quality parameter and heavy metal concentration in the water of Buriganga river, adjoining to Dhaka city. Water samples were collected from five different points of Buriganga river and were analyzed to determine pH, electrical conductivity (EC), total dissolved solids (TDS), dissolved oxygen (DO), biological oxygen demand (BOD), chromium (Cr), lead (Pb), cadmium (Cd), copper (Cu) and manganese (Mn) content. Most of the measured water quality parameters and concentration of heavy metals were exceeded the standard level set by ECR and ADB. Among heavy metals concentration, level of chromium and cadmium were 4-5 times higher than the standard drinking level, these results indicate that surrounding industrial wastewater discharging from textile and tannery industries, which pollute the Buriganga river water. During the observation, at Hazaribagh station BOD level was found 32 times higher than drinking water standard level and 6 times higher than standard irrigation level, indicating Buriganga river water is extremely polluted by microorganism and is not suitable for household and irrigational use. Similarly, DO level at Buriganga river water was 5 times lower than the standard level, which indicates that Buriganga river water is extremely polluted and is unsuitable for aquatic life which are dependent on DO for their sustain. In the present study, the measured level of EC, chromium, cadmium and copper were found higher level as compare to the previous studies.J. Environ. Sci. & Natural Resources, 9(2): 97-104 2016


The present paper describes the application of GIS to study the spatial and temporal variations of some important water quality parameters in the Veeranam tank drainage basin of cuddalore district, Tamil Nadu, South India. The water quality parameters were depicted by various colour combinations for different ranges of concentrations. Twenty four (24) groundwater samples were collected from bore wells for two different seasons, pre monsoon in July 2015 and postmonsoon in January 2016. The collected water samples were analyzed for chemical constituents, such as chloride, sulphate, bicarbonate, carbonate, nitrate, sodium, potassium, calcium and magnesium in the laboratory, by following the standard procedures described by the American Public Health Association (APHA 1998). Spatial distribution map for Electrical conductivity, Hardness, Calcium, Magnesium, Sulphate and Chloride in pre-monsoon and post monsoon samples was generated by ArcGIS 9.3 software. The study implies that the quality of groundwater is generally good and potable in the nearby Veeranam lake and the quality becomes moderate as it passes away from Veeranam tank of the study area.