scholarly journals Analysis Effects of Average Value of Convective and Evaporative Heat Transfer Coefficient on Solar Cabinet Dryer for Reduction of Mass of Papad

Author(s):  
Goldi Mathuriya

Abstract: In this research paper, the behavior of heat and mass transfer phenomenon during greenhouse papad drying under forced convection mode has been investigated. Various experiments were performed during the month of April 2020 at SRCEM Banmore, morena (26o 34’13” N 78o 10’48” E). Experimental data obtained for forced convection greenhouse drying of papad were used to determine the constants in the Nusselt number expression by using the simple linear regression analysis and, consequently, the values of convective and evaporative heat transfer coefficients were evaluated. The average values of experimental constants C and n were determined as 0.9714 and 0.0129 respectively. The average values of convective and evaporative heat transfer coefficients were determined as 0.0886 W/m2 oC and 6.7583 W/m2 oC respectively. The experimental error in terms of percentage uncertainty was also evaluated. Keywords: Papad, Papad drying, Heat transfer coefficient, Convective, Evaporative, Forced convection greenhouse

2017 ◽  
Vol 15 (3) ◽  
pp. 467
Author(s):  
Ravinder Kumar Sahdev ◽  
Mahesh Kumar ◽  
Ashwani Kumar Dhingra

In this paper, convective and evaporative heat transfer coefficients of the Indian groundnut were computed under indoor forced convection drying (IFCD) mode. The groundnuts were dried as a single thin layer with the help of a laboratory dryer till the optimum safe moisture storage level of 8 – 10%. The experimental data were used to determine the values of experimental constants C and n in the Nusselt number expression by a simple linear regression analysis and consequently, the convective heat transfer coefficient (CHTC) was determined. The values of CHTC were used to calculate the evaporative heat transfer coefficient (EHTC). The average values of CHTC and EHTC were found to be 2.48 W/m2 oC and 35.08 W/m2 oC, respectively. The experimental error in terms of percent uncertainty was also estimated. The experimental error in terms of percent uncertainty was found to be 42.55%. The error bars for convective and evaporative heat transfer coefficients are also shown for the groundnut drying under IFCD condition.


2016 ◽  
Vol 14 (1) ◽  
pp. 101 ◽  
Author(s):  
Mahesh Kumar

In this research paper, the convective and the evaporative heat transfer coefficients of ginger (zingiber officinale) drying in an indirect solar cabinet dryer under the induced forced convection mode is presented. Experiments were conducted during the month of March 2015 under the climatic conditions of Hisar, India (29°5’5”N latitude and 75°45’55”E longitude). The experimental data obtained for solar drying of a constant ginger mass of 150 g has been used to determine constants ‘C’ and ‘n’ in the Nusselt number expression using linear regression analysis; consequently, the convective and the evaporative heat transfer coefficients have been evaluated. The average value of constants ‘C’ and ‘n’ were evaluated as 0.999 and 0.318, respectively. The average values of the convective and the evaporative heat transfer coefficients were found to be 3.95 W/m2 °C and 160.47 W/m2 °C, respectively, for the given mass samples of ginger. The average collector efficiency was observed to be 14.5%. The experimental error in terms of percentage uncertainty was found to be 20.87%.


2013 ◽  
Vol 24 (4) ◽  
pp. 37-43 ◽  
Author(s):  
Mahesh Kumar

In this paper, the convective heat transfer coefficients of papad for greenhouse drying under a natural convection mode are reported. Various experiments were conducted during the month of April 2010 at Guru Jambheshwar University of Science and Technology Hisar, India (29o5’5” N 75o45’55” E). Experimental data obtained for the natural convection greenhouse drying of papad was used to evaluate the constants in the Nusselt number expression by using simple linear regression analysis. These values of the constant were used further to determine the values of the convective heat transfer coefficient. The average value of a convective heat transfer coefficient was determined as 1.23 W/m2 oC. The experimental error in terms of percent uncertainty was also evaluated.


Author(s):  
Ann-Christin Fleer ◽  
Markus Richter ◽  
Roland Span

AbstractInvestigations of flow boiling in highly viscous fluids show that heat transfer mechanisms in such fluids are different from those in fluids of low viscosity like refrigerants or water. To gain a better understanding, a modified standard apparatus was developed; it was specifically designed for fluids of high viscosity up to 1000 Pa∙s and enables heat transfer measurements with a single horizontal test tube over a wide range of heat fluxes. Here, we present measurements of the heat transfer coefficient at pool boiling conditions in highly viscous binary mixtures of three different polydimethylsiloxanes (PDMS) and n-pentane, which is the volatile component in the mixture. Systematic measurements were carried out to investigate pool boiling in mixtures with a focus on the temperature, the viscosity of the non-volatile component and the fraction of the volatile component on the heat transfer coefficient. Furthermore, copper test tubes with polished and sanded surfaces were used to evaluate the influence of the surface structure on the heat transfer coefficient. The results show that viscosity and composition of the mixture have the strongest effect on the heat transfer coefficient in highly viscous mixtures, whereby the viscosity of the mixture depends on the base viscosity of the used PDMS, on the concentration of n-pentane in the mixture, and on the temperature. For nucleate boiling, the influence of the surface structure of the test tube is less pronounced than observed in boiling experiments with pure fluids of low viscosity, but the relative enhancement of the heat transfer coefficient is still significant. In particular for mixtures with high concentrations of the volatile component and at high pool temperature, heat transfer coefficients increase with heat flux until they reach a maximum. At further increased heat fluxes the heat transfer coefficients decrease again. Observed temperature differences between heating surface and pool are much larger than for boiling fluids with low viscosity. Temperature differences up to 137 K (for a mixture containing 5% n-pentane by mass at a heat flux of 13.6 kW/m2) were measured.


Author(s):  
Jatuporn Kaew-On ◽  
Somchai Wongwises

The evaporation heat transfer coefficients and pressure drops of R-410A and R-134a flowing through a horizontal-aluminium rectangular multiport mini-channel having a hydraulic diameter of 3.48 mm are experimentally investigated. The test runs are done at refrigerant mass fluxes ranging between 200 and 400 kg/m2s. The heat fluxes are between 5 and 14.25 kW/m2, and refrigerant saturation temperatures are between 10 and 30 °C. The effects of the refrigerant vapour quality, mass flux, saturation temperature and imposed heat flux on the measured heat transfer coefficient and pressure drop are investigated. The experimental data show that in the same conditions, the heat transfer coefficients of R-410A are about 20–50% higher than those of R-134a, whereas the pressure drops of R-410A are around 50–100% lower than those of R-134a. The new correlations for the evaporation heat transfer coefficient and pressure drop of R-410A and R-134a in a multiport mini-channel are proposed for practical applications.


1993 ◽  
Vol 115 (4) ◽  
pp. 231-236 ◽  
Author(s):  
V. B. Sharma ◽  
S. C. Mullick

An approximate method for calculation of the hourly output of a solar still over a 24-hour cycle has been studied. The hourly performance of a solar still is predicted given the values of the insolation, ambient temperature, wind heat-transfer coefficient, water depth, and the heat-transfer coefficient through base and sides. The proposed method does not require graphical constructions and does not assume constant heat-transfer coefficients as in the previous methods. The possibility of using the values of the heat-transfer coefficients for the preceding time interval in the heat balance equations is examined. In fact, two variants of the basic method of calculation are examined. The hourly rate of evaporation is obtained. The results are compared to those obtained by numerical solution of the complete set of heat balance equations. The errors from the approximate method in prediction of the 24-hour output are within ±1.5 percent of the values from the numerical solution using the heat balance equations. The range of variables covered is 5 to 15 cms in water depth, 0 to 3 W/m2K in a heat-transfer coefficient through base and sides, and 5 to 40 W/m2K in a wind heat-transfer coefficient.


Author(s):  
Nirm V. Nirmalan ◽  
Ronald S. Bunker ◽  
Carl R. Hedlung

A new method has been developed and demonstrated for the non-destructive, quantitative assessment of internal heat transfer coefficient distributions of cooled metallic turbine airfoils. The technique employs the acquisition of full-surface external surface temperature data in response to a thermal transient induced by internal heating/cooling, in conjunction with knowledge of the part wall thickness and geometry, material properties, and internal fluid temperatures. An imaging Infrared camera system is used to record the complete time history of the external surface temperature response during a transient initiated by the introduction of a convecting fluid through the cooling circuit of the part. The transient data obtained is combined with the cooling fluid network model to provide the boundary conditions for a finite element model representing the complete part geometry. A simple 1D lumped thermal capacitance model for each local wall position is used to provide a first estimate of the internal surface heat transfer coefficient distribution. A 3D inverse transient conduction model of the part is then executed with updated internal heat transfer coefficients until convergence is reached with the experimentally measured external wall temperatures as a function of time. This new technique makes possible the accurate quantification of full-surface internal heat transfer coefficient distributions for prototype and production metallic airfoils in a totally non-destructive and non-intrusive manner. The technique is equally applicable to other material types and other cooled/heated components.


2000 ◽  
Author(s):  
M. Kumagai ◽  
R. S. Amano ◽  
M. K. Jensen

Abstract A numerical and experimental investigation on cooling of a solid surface was performed by studying the behavior of an impinging jet onto a fixed flat target. The local heat transfer coefficient distributions on a plate with a constant heat flux were computationally investigated with a normally impinging axisymmetric jet for nozzle diameter of 4.6mm at H/d = 4 and 10, with the Reynolds numbers of 10,000 and 40,000. The two-dimensional cylindrical Navier-Stokes equations were solved using a two-equation k-ε turbulence model. The finite-volume differencing scheme was used to solve the thermal and flow fields. The predicted heat transfer coefficients were compared with experimental measurements. A universal function based on the wave equation was developed and applied to the heat transfer model to improve calculated local heat transfer coefficients for short nozzle-to-plate distance (H/d = 4). The differences between H/d = 4 and 10 due to the correlation among heat transfer coefficient, kinetic energy and pressure were investigated for the impingement region. Predictions by the present model show good agreement with the experimental data.


2000 ◽  
Author(s):  
Edward V. McAssey ◽  
Jinfeng Wu ◽  
Thomas Dougherty ◽  
Bao Wen Yang

Abstract Data are presented for sub-cooled boiling of water in the range of two to four atmospheres. The results show that the sharp increase in heat transfer coefficient associated with nucleate boiling occurs at wall superheats of 20 °C to 30 °C. Comparisons between experimental and predicted heat transfer coefficients are also presented. The two prediction methods examined are the Chen correlation and the Kandlikar correlation.


2014 ◽  
Vol 925 ◽  
pp. 625-629 ◽  
Author(s):  
C.S. Oon ◽  
A. Badarudin ◽  
S.N. Kazi ◽  
M. Fadhli

The heat transfer in annular heat exchanger with titanium oxide of 1.0 volume % concentration as the medium of heat exchanger is considered in this study. The heat transfer simulation of the flow is performed by using Computational Fluid Dynamics package, Ansys Fluent. The heat transfer coefficients of water to titanium oxide nanofluid flowing in a horizontal counter-flow heat exchanger under turbulent flow conditions are investigated. The results show that the convective heat transfer coefficient of the nanofluid is slightly higher than that of the base fluid by several percents. The heat transfer coefficient increases with the increase of the mass flow rate of hot water and also the nanofluid.