Toxicokinetic evaluation of the common indoor air pollutant, α-pinene, and its potential reactive metabolite, α-pinene oxide, following inhalation exposure in rodents

Author(s):  
2021 ◽  
Vol 418 ◽  
pp. 115496
Author(s):  
Suramya Waidyanatha ◽  
Michael Hackett ◽  
Sherry R. Black ◽  
Mathew D. Stout ◽  
Timothy R. Fennell ◽  
...  

2019 ◽  
Vol 14 (1) ◽  
Author(s):  
Shiqiang Zhou ◽  
Mingpeng Chen ◽  
Qingjie Lu ◽  
Yumin Zhang ◽  
Jin Zhang ◽  
...  

AbstractFormaldehyde (HCHO) is the main source of indoor air pollutant. HCHO sensors are therefore of paramount importance for timely detection in daily life. However, existing sensors do not meet the stringent performance targets, while deactivation due to sensing detection at room temperature, for example, at extremely low concentration of formaldehyde (especially lower than 0.08 ppm), is a widely unsolved problem. Herein, we present the Ag nanoparticles (Ag NPs) sensitized dispersed In2O3 nanograin via a low-fabrication-cost hydrothermal strategy, where the Ag NPs reduces the apparent activation energy for HCHO transporting into and out of the In2O3 nanoparticles, while low concentrations detection at low working temperature is realized. The pristine In2O3 exhibits a sluggish response (Ra/Rg = 4.14 to 10 ppm) with incomplete recovery to HCHO gas. After Ag functionalization, the 5%Ag-In2O3 sensor shows a dramatically enhanced response (135) with a short response time (102 s) and recovery time (157 s) to 1 ppm HCHO gas at 30 °C, which benefits from the Ag NPs that electronically and chemically sensitize the crystal In2O3 nanograin, greatly enhancing the selectivity and sensitivity.


1986 ◽  
Vol 12 (1-4) ◽  
pp. 351-362 ◽  
Author(s):  
Ken Sexton ◽  
Lurance M. Webber ◽  
Steven B. Hayward ◽  
Richard G. Sextro

2010 ◽  
Vol 12 (12) ◽  
pp. 2244 ◽  
Author(s):  
Paul Delaney ◽  
Robert M. Healy ◽  
John P. Hanrahan ◽  
Lorraine T. Gibson ◽  
John C. Wenger ◽  
...  

2016 ◽  
Vol 311 ◽  
pp. 37-42 ◽  
Author(s):  
Yanjian Wan ◽  
Jingchuan Xue ◽  
Kurunthachalam Kannan

2014 ◽  
Vol 29 (suppl.) ◽  
pp. 52-58
Author(s):  
Franz Roessler ◽  
Jai Azzam ◽  
Volker Grimm ◽  
Hans Hingmann ◽  
Tina Orovwighose ◽  
...  

The energy conservation regulation provides upper limits for the annual primary energy requirements for new buildings and old building renovation. The actions required could accompany a reduction of the air exchange rate and cause a degradation of the indoor air quality. In addition to climate and building specific aspects, the air exchange rate is essentially affected by the residents. Present methods for the estimation of the indoor air quality can only be effected under test conditions, whereby the influence of the residents cannot be considered and so an estimation under daily routine cannot be ensured. In the context of this contribution first steps of a method are presented, that allows an estimation of the progression of the air exchange rate under favourable conditions by using radon as an indicator. Therefore mathematical connections are established that could be affirmed practically in an experimental set-up. So this method could provide a tool that allows the estimation of the progression of the air exchange rate and in a later step the estimation of a correlating progression of air pollutant concentrations without limitations of using the dwelling.


2005 ◽  
Vol 125 (6) ◽  
pp. 517-523 ◽  
Author(s):  
Hiromu TSUTSUMI ◽  
Yuichi MIHARA ◽  
Norihiro OGAWA ◽  
Toru HOSHINO ◽  
Takeshi KUMAGAI ◽  
...  
Keyword(s):  

2018 ◽  
Vol 19 (10) ◽  
pp. 2966 ◽  
Author(s):  
Shu-Ye Jiang ◽  
Ali Ma ◽  
Srinivasan Ramachandran

Negative air ions (NAIs) have been discovered for more than 100 years and are widely used for air cleaning. Here, we have carried out a comprehensive reviewing on the effects of NAIs on humans/animals, and microorganisms, and plant development. The presence of NAIs is credited for increasing psychological health, productivity, and overall well-being but without consistent or reliable evidence in therapeutic effects and with controversy in anti-microorganisms. Reports also showed that NAIs could help people in relieving symptoms of allergies to dust, mold spores, and other allergens. Particulate matter (PM) is a major air pollutant that affects human health. Experimental data showed that NAIs could be used to high-efficiently remove PM. Finally, we have reviewed the plant-based NAI release system under the pulsed electric field (PEF) stimulation. This is a new NAI generation system which releases a huge amount of NAIs under the PEF treatment. The system may be used to freshen indoor air and reduce PM concentration in addition to enriching oxygen content and indoor decoration at home, school, hospital, airport, and other indoor areas.


2014 ◽  
Vol 40 (3) ◽  
pp. 259-268 ◽  
Author(s):  
Ana Maria da Conceição Ferreira ◽  
Massano Cardoso

Objective: To determine whether indoor air quality in schools is associated with the prevalence of allergic and respiratory diseases in children. Methods: We evaluated 1,019 students at 51 elementary schools in the city of Coimbra, Portugal. We applied a questionnaire that included questions regarding the demographic, social, and behavioral characteristics of students, as well as the presence of smoking in the family. We also evaluated the indoor air quality in the schools. Results: In the indoor air of the schools evaluated, we identified mean concentrations of carbon dioxide (CO2) above the maximum reference value, especially during the fall and winter. The CO2 concentration was sometimes as high as 1,942 ppm, implying a considerable health risk for the children. The most prevalent symptoms and respiratory diseases identified in the children were sneezing, rales, wheezing, rhinitis, and asthma. Other signs and symptoms, such as poor concentration, cough, headache, and irritation of mucous membranes, were identified. Lack of concentration was associated with CO2 concentrations above the maximum recommended level in indoor air (p = 0.002). There were no other significant associations. Conclusions: Most of the schools evaluated presented with reasonable air quality and thermal comfort. However, the concentrations of various pollutants, especially CO2, suggest the need for corrective interventions, such as reducing air pollutant sources and improving ventilation. There was a statistically significant association between lack of concentration in the children and exposure to high levels of CO2. The overall low level of pollution in the city of Coimbra might explain the lack of other significant associations.


Sign in / Sign up

Export Citation Format

Share Document