scholarly journals Gestation in a Mare with Facial Deviation (Wry Nose)

2019 ◽  
Vol 47 ◽  
Author(s):  
Mariana Andrade Mousquer ◽  
Vitória Müller ◽  
Fernanda Maria Pazinato ◽  
Bruna Dos Santos Suñe Moraes ◽  
Leandro Américo Rafael ◽  
...  

Background: Wry nose is a congenital deformity that causes respiratory obstruction and decreased oxygenation rate. Gestation in a wry nose mare may be considered a risk to the neonate since it depends on the maternal environment for development. Compromised oxygenation during pregnancy can lead to fetal distress and cause consequences on fetal development. However, depending on the degree of the impairment, the fetus may still be able to adapt. The aim of the present study was to report the gestation in a mare with facial deviation until term and to assess blood gases in the mare and neonate, and to evaluate the histomorphometry of the placenta.Case: A Criollo breed mare presenting facial deviation (Wry Nose) was donated to Equine Medicine Research Group (ClinEq) of the Federal University of Pelotas (UFPel) due to the presence of the physical deformity. When the mare was five years old, it was inseminated and had a pregnancy confirmed. At the fifth month of gestation, evaluation of fetal aorta diameter, fetal orbital diameter and combined thickness of the uterus and placenta (CTUP) started to be performed monthly to assess gestation health. The assessment of the fetal orbit and aorta diameter revealed a linear increase of both variables with the progress of gestation indicating a normal fetal development.  CTUP remained in the normal reference range, presenting no alterations during the gestational length. The mare foaled at 324 days of gestation a coat showing no congenital deformities. The foaling was monitored until the complete passage of fetal membranes. A complete clinical and hematological evaluation of the foal was carried out after birth. The foal showed normal adaptive behavior, clinical and hematological parameters during the first hours of life, although presenting physical signs of immaturity. Venous blood samples were collected from the mare at 315 days of gestation, immediately after foaling and 24 h post-partum for lactate and blood gas analysis.  Mild changes were observed in the mare’s blood gas analysis at foaling that were compensated within 24 h post-partum. Venous blood samples were collected from the umbilical cord and from the foal after birth, at 12 and 24 h post-partum to measure blood gases and lactate. The newborn foal presented respiratory acidosis immediately after birth, which was metabolically compensated at 24 h post-partum. Both mare’s and foal’s lactate evaluation were within the normal reference ranges. After expulsion of the placenta, samples from the gravid horn, uterine body and non-gravid horn were collected for histological and histomorphometric evaluation. In the histological evaluation, avillous areas were detected in the gravid horn and uterine body and mild hypoplasia was found in the uterine body. Placental histomorphometry revealed larger total microcotiledonary and capillary areas on the non-gravid horn when compared to the remaining areas of the placenta (gravid horn and uterine body). No abnormalities on the placental vasculature were detected.  Discussion: To date, there are no reports of a pregnancy in a mare with facial deviation in the literature. This report showed that the wry nose mare gave birth to a viable foal showing no congenital abnormalities, which suggests that wry nose animals can be bred normally. The mare presented a healthy pregnancy, with mild changes in the blood gas analysis at foaling that were compensated at 24 h postpartum. Similarly, despite the foal showed physical signs of immaturity and respiratory acidosis at birth, these changes were compensated in the later assessments. Furthermore, no abnormalities on the placental vasculature were detected.

2019 ◽  
Vol 6 (4) ◽  
pp. 1016
Author(s):  
Sabiha Naz ◽  
Kiran Chugh ◽  
Isha Malik

Background: It is clearly mentioned in the medicine books that blood gas analysis from arterial puncture is the gold standard. But in the past few years it is commonly seen that clinicians have started trusting on venous blood gas analysis as well as started advising VBG (Venous blood gas) in the initial diagnosis of critical patients in emergency setting. Keeping this fact in mind, we designed a study to determine whether VBG could be a better replacement of ABG (Arterial blood gases) in the emergency where diverse pathological conditions are encountered.Methods: This prospective cross-sectional study comprised of 50 patients of 20-60 yrs age with a variety of diagnoses admitted in the emergency department. 50 paired samples (ABG+VBG) were obtained from them under strict aseptic precautions after obtaining their verbal consent. With a minimum delay of less than 2 min blood gas analysis was performed on blood gas analyzer. Parameters (pH, PCO2, PO2, HCO3, Base Excess and O2 saturation) from ABG and VBG were recorded and compared using Student’s Unpaired ‘t’ test.Results: pH and HCO3 showed statistical significant (p value <0.05) differences between ABG and VBG, while BE showed statistical non-significant (p value >0.05) difference between them. Contrary to this, PCO2, PO2 and O2 saturation from ABG and VBG showed statistical highly significant (p value <0.0001) differences.Conclusions: VBG should not be interchangeably considered in place of ABG with regard to pH, HCO3, PCO2, PO2 and O2 saturation in conditions where actual oxygenation status of patient is required (e.g.; hypovolemic shock, respiratory disorders, mechanically ventilated patients, etc.)


1994 ◽  
Vol 40 (1) ◽  
pp. 124-129 ◽  
Author(s):  
R J Wong ◽  
J J Mahoney ◽  
J A Harvey ◽  
A L Van Kessel

Abstract We evaluated a new portable instrument, the PPG StatPal II pH and Blood Gas Analysis System, designed for "point-of-care" measurements of blood gases and pH. Inaccuracy (% of target value) and imprecision (CV%) were assessed by blood tonometry and comparison with a Corning 178. Within-day results for PCO2 inaccuracy and imprecision ranged from 98.2% to 102.9% and 3.3% to 3.9%, respectively; for PO2, these were 95.5% to 102.3% and 2.3% to 3.0%, respectively. Between-day results for PCO2 inaccuracy and imprecision ranged from 99.2% to 99.3% and from 2.9% to 3.2%, respectively; for PO2, the ranges were 96.2% to 98.2% and 2.6% to 3.0%, respectively. Two PCO2 outliers (in 645 samples = 0.3%) were observed. In general, tonometry recovery, measurement stability, and pH bias results for the StatPal II and Corning 178 were comparable. We conclude that the StatPal II performs within acceptable ranges of inaccuracy and imprecision.


2018 ◽  
Vol 29 (1) ◽  
pp. 169-172
Author(s):  
Gian Luca Salvagno ◽  
Davide Demonte ◽  
Giuseppe Lippi

A 51-year old male patient was admitted to the hospital with acute dyspnea and history of chronic asthma. Venous blood was drawn into a 3.0 mL heparinized syringe and delivered to the laboratory for blood gas analysis (GEM Premier 4000, Instrumentation Laboratory), which revealed high potassium value (5.2 mmol/L; reference range on whole blood, 3.5-4.5 mmol/L). This result was unexpected, so that a second venous blood sample was immediately drawn by direct venipuncture into a 3.5 mL lithium-heparin blood tube, and delivered to the laboratory for repeating potassium testing on Cobas 8000 (Roche Diagnostics). The analysis revealed normal plasma potassium (4.6 mmol/L; reference range in plasma, 3.5-5.0 mmol/L) and haemolysis index (5; 0.05 g/L). Due to suspicion of spurious haemolysis, heparinized blood was transferred from syringe into a plastic tube and centrifuged. Potassium and haemolysis index were then measured in this heparinized plasma, confirming high haemolysis index (50; 0.5 g/L) and pseudohyperkalemia (5.5 mmol/L). Investigation of this case revealed that spurious haemolysis was attributable to syringe delivery in direct ice contact for ~15 min. This case emphasizes the importance of avoiding sample transportation in ice and the need of developing point of care analysers equipped with interference indices assessment.


2009 ◽  
Vol 28 (2) ◽  
pp. 125-128 ◽  
Author(s):  
Mary Farmand

UNDERSTANDING BLOOD GAS values and acid-base balance are fundamental skills of neonatal nursing. This is because, in the NICU, blood gases are probably ordered more than any other laboratory test. The bedside nurse not only obtains the specimen, but is also crucially involved in interpreting the results because blood gases cannot stand alone; they need to be evaluated in the context of the entire clinical picture. This article provides basic information on the components of a blood gas, acid-base balance, as well as a systematic approach to blood gas analysis.


2021 ◽  
Vol 20 (3) ◽  
pp. 178-182
Author(s):  
Ram Kirubakar Thangaraj ◽  
Hari Hara Sudhan Chidambaram ◽  
Melvin Dominic ◽  
V.P. Chandrasekaran ◽  
Karthik Narayan Padmanabhan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document