scholarly journals Proposal for a semi-quantitative method for the determination of volatile compounds in cocoa liquors

Respuestas ◽  
2020 ◽  
Vol 25 (1) ◽  
Author(s):  
Cristian Palencia-Blanco ◽  
Alejandra Gualdrón-Zambrano ◽  
Isabel Guarín - Henao ◽  
Yuly Ojeda-Galeano ◽  
Arley Villamizar-Jaimes ◽  
...  

Seventy-four volatile compounds were identified and quantified from cocoa liquors of the ICS 95 and TCS 01 varieties produced in the department of Santander, Colombia. The compounds were extracted using the solid phase microextraction with head space (SPME-HS) technique, and identified by gas chromatography coupled to mass spectrometer (GC-MS) by comparing the mass spectra of each compound in the Wiley 275L library of mass spectra and the Kovats retention index (IK) ratio. A semi-quantitative method was proposed that included toluene as an internal standard to normalize the degree of recovery between samples and a response factor for each family, calculated using a compound characteristic of that functional group. The results associated with response factors for each family or group of compounds such as alcohols, acids, aldehydes, ketones, esters and pyrazines (2.19, 1.02, 2.84, 0.38, 6.38, 0.88 respectively) were different between families, however, there was no difference between compounds within the same family. The implemented method obtained a DOD and DML of 0.024 µg/kg and 0.037 µg/kg respectively and an accuracy expressed as percentage recovery (of characteristic compounds per family) of 96% on average. According to the precision of the method, the results show that the concentrations have an average coefficient of variation (%CV) of 7.38% assuring repeatability and good precision. Finally, for the analyzed and quantified samples, it was found that the compounds with higher concentration were acetic acid (42.633 mg/kg), 2-phenylethyl acetate (29.44 mg/kg), 2.3-butanediol (345.39 mg/kg), 2-phenylethanol (12.595mg/kg) and 2.3.5.6-tetramethylpyrazine (8.601 mg/kg).

2012 ◽  
Vol 11 (1) ◽  
pp. 55-63 ◽  
Author(s):  
Maizbha Uddin Ahmed ◽  
Mohammad Safiqul Islam ◽  
Tasmin Ara Sultana ◽  
AGM Mostofa ◽  
Muhammad Shahdaat Bin Sayeed ◽  
...  

Azithromycin is an effective and well-known antimicrobial agent. In the present study, a simple, sensitive and specific LC/MS/MS method has been developed and validated for the quantification of Azithromycin in  human serum samples using Clarithromycin as internal standard. Azithromycin was extracted from biological matrix  by using solid phase extraction process. The chromatographic separation was performed on Luna C18 (3 ?, 2x150   mm) column with a mobile phase consisting of 35 mM ammonium acetate buffer (mobile phase-A) and acetonitrile  and methanol in ratio of 90:10 ( as mobile phase-B) at a flow rate of 0.25 mL/min. The method was validated over a  linear concentration range of 0.5?50.0 ng/mL and limit of quantification (LOQ) was 0.5 ng/mL with a coefficient of  correlation (r2) = 0.9998. The intra-day and inter-day precision expressed as relative standard deviation were 1.64% – 8.43% and 2.32% – 9.92%, respectively. The average recovery of azithromycin from serum was 98.11%. The method  was successfully applied to a pharmacokinetic study after oral administration of Azithromycin 200 mg/5 ml suspension in healthy Bangladeshi volunteers. DOI: http://dx.doi.org/10.3329/dujps.v11i1.12488 Dhaka Univ. J. Pharm. Sci. 11(1): 55-63, 2012 (June)


2013 ◽  
Vol 96 (6) ◽  
pp. 1302-1307 ◽  
Author(s):  
Karim Michail ◽  
Hoda Daabees ◽  
Youssef Beltagy ◽  
Magdy Abd Elkhalek ◽  
Mona Khamis

Abstract A validated HPLC-UV method is presented for the quantification of urinary memantine hydrochloride, a novel medication approved to treat moderate and advanced cases of Alzheimer's disease. The drug and amantadine hydrochloride, the internal standard, were extracted from human urine using SPE. The extract was then buffered and derivatized at room temperature using o-phthalaldehyde in the presence of N-acetyl-L-cyteine. Chromatographic separation of the formed derivatives was achieved on a C18 column using methanol–water mobile phase adjusted to pH 7 and pumped isocratically at 1 mL/min. The UV detector was set at 340 nm. The chromatographic run time did not exceed 10 min. The LOD and LOQ were 8 and 20 ng/mL, respectively. The RSDs for intraday and interday precisions did not exceed 5.5%. The method was used to monitor memantine hydrochloride in human urine in order to determine an appropriate sampling interval for future noninvasive therapeutic drug monitoring. The assay could also be applied to the determination of amantadine. The described assay showed that a postdosing time interval of 25–75 h seems adequate for sampling and monitoring memantine in urine.


2010 ◽  
Vol 5 ◽  
pp. ACI.S4431 ◽  
Author(s):  
Liusheng Huang ◽  
Patricia S. Lizak ◽  
Anura L. Jayewardene ◽  
Florence Marzan ◽  
Ming-Na Tina Lee ◽  
...  

An HPLC-UV method was developed and validated for the determination of lumefantrine in human plasma. Lumefantrine and its internal standard halofantrine were extracted from plasma samples using protein precipitation with acetonitrile (0.2% perchloric acid) followed by solid-phase extraction with Hypersep C8 cartridges. Chromatographic separation was performed on a Zorbax SB-CN HPLC column (3.0 × 150 mm, 3.5 μm) with water/methanol (0.1% TFA) as the mobile phases in a gradient elution mode. Detection was performed using UV/vis detector at λ = 335 nm. The method showed to be linear over a range of 50-10,000 ng/mL with acceptable intra- and inter-day precision and accuracy. The mean recoveries were 88.2% for lumefatrine and 84.5% for the I.S. The internal standard halofantrine is readily available from commercial sources. This method was successfully applied to a pharmacokinetic interaction study between a first-line antimalarial combination (artemether—lumefantrine) and antiretroviral therapy.


2003 ◽  
Vol 68 (11) ◽  
pp. 883-892 ◽  
Author(s):  
Dragica Zendelovska ◽  
Trajce Stafilov

A rapid, specific and sensitive high-performance liquid chromatographic method for the determination of famotidine in human plasma has been developed. Famotidine and the internal standard were chromatographically separated from plasma components using a Lichrocart Lichrospher 60 RP select B cartridge for solid-phase separation with a mobile phase composed of 0.1 % (v/v) triethylamine in water (pH 3) and acetonitrile (92:8, v/v). UV detection was set at 270 nm. The calibration curve was linear in the concentration range of 10.0 ? 350.0 ng mL-1. The method was implemented to monitor the famotidine levels in patient samples.


2009 ◽  
Vol 6 (1) ◽  
pp. 223-230 ◽  
Author(s):  
G. A. Temghare ◽  
S. S. Shetye ◽  
S. S. Joshi

A rapid and sensitive liquid chromatography-mass spectrometric (LC-MS-MS) method for the simultaneous determination of lopinavir and ritonavir in human plasma using abacavir as internal standard has been developed and validated. Sample preparation of plasma involved solid phase extraction. Detection was performed using an Applied Biosystems Sciex API 2000 Mass spectrometer. The assay of lopinavir and ritonavir was linear over the range of 50 ng mL-1to 20000 ng mL-1and 20 ng mL-1to 3000 ng mL-1 respectively with a precision of <15% and accuracy in the range of 85-115%. The limit of quantification in plasma for lopinavir and ritonavir was 50 ng mL-1and 20 ng mL-1respectively. The described method has the advantage of being rapid and easy and it could be applied in therapeutic monitoring of these drugs in human plasma


OCL ◽  
2020 ◽  
Vol 27 ◽  
pp. 20
Author(s):  
Andrea Milani ◽  
Paolo Lucci ◽  
Martina Sedran ◽  
Erica Moret ◽  
Sabrina Moret ◽  
...  

The evaluation of the content of waxes is request both by IOC Trade Standard and by Regulation (EEC) 2568/91 and its further amendments. The official method uses 15 g of silicic acid and elutes several fractions by using huge volumes of dangerous solvent (n-hexane). The developed method uses 1 g of silicic acid with a different particle size and less than 20 mL of solvent mixture, substituting n-hexane with less toxic isooctane. Briefly, after spiking with a suitable internal standard, oil sample is fractionated by SPE (Solid Phase Extraction) cartridge with 1 g of silica, waxes are eluted with 14 mL of isooctane/ethyl ether 99/1 (6 mL discarded and 8 mL collected), then, after elution sample is reconstitute in 200 μL of n-heptane and analysed by capillary GC. Data of “In home” validation, (repeatability, accuracy and recovery) and relative chromatograms are reported in this paper.


Sign in / Sign up

Export Citation Format

Share Document