scholarly journals A multi-centre experience of ablation index for evaluating lesion delivery in cavotricuspid isthmus dependent atrial flutter

Author(s):  
Edd Maclean ◽  
Ron Simon ◽  
Richard Ang ◽  
Gurpreet Dhillon ◽  
Syed Ahsan ◽  
...  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Manabu Kashiwagi ◽  
Akio Kuroi ◽  
Yosuke Katayama ◽  
Kosei Terada ◽  
Suwako Fujita ◽  
...  

AbstractCavotricuspid isthmus (CTI) linear ablation has been established as the treatment for typical atrial flutter. Recently, ablation index (AI) has emerged as a novel marker for estimating ablation lesions. We investigated the relationship between CTI depth and ablation parameters on the procedural results of typical atrial flutter ablation. A total of 107 patients who underwent CTI ablation were retrospectively enrolled in this study. All patients underwent computed tomography before catheter ablation. From the receiver-operating curve, the best cut-off value of CTI depth was < 4.1 mm to predict first-pass success. Although the average AI was not different between deep CTI (DC; CTI depth ≥ 4.1) and shallow CTI (SC; CTI depth < 4.1), DC required a longer ablation time and showed a lower first-pass success rate (p < 0.01). In addition, the catheter inversion technique was more frequently required in the DC (p < 0.01). The lowest AI sites of the first-pass CTI line were determined in both the ventricular (2/3 segment of CTI) and inferior vena cava (IVC, 1/3 segment of CTI) sides. The best cut-off values of the weakest AIs at the ventricular and IVC sides for predicting first-pass success were > 420 and > 386, respectively. Among patients with these cut-off values, the first-pass success rate was 89% in the SC and 50% in the DC (p < 0.01). Although ablation parameters were not significantly different, the first-pass success rate was lower in the DC than in the SC. Further investigation might be required for better outcomes in deep CTIs.


2021 ◽  
Author(s):  
Manabu Kashiwagi ◽  
Akio Kuroi ◽  
Yosuke Katayama ◽  
Kosei Terada ◽  
Suwako Fujita ◽  
...  

Abstract Cavotricuspid isthmus (CTI) linear ablation has been established as the treatment for typical atrial flutter. Recently, ablation index (AI) has emerged as a novel marker for estimating ablation lesions. We investigated the relationship between CTI anatomy and ablation parameters. In addition, we focused on the influence of AI on the procedural results of typical atrial flutter ablation. A total of 107 patients who underwent CTI ablation were retrospectively enrolled in this study. All patients underwent computed tomography before catheter ablation. From the receiver-operating curve, the best cut-off value of CTI depth was < 4.1 mm to predict first-pass success. The patients were divided into two groups according to the CTI depth: the concave group (CG) and straight group (SG). Although the average AI was not different between both groups, the CG required a longer ablation time and showed a lower first-pass success rate (p < 0.01). In addition, the catheter inversion technique was more frequently required in the CG (p < 0.01). The best cut-off values of the weakest AIs at the anterior and posterior lesions for predicting first-pass success were >420 and >386, respectively. Among patients with these cut-off values, the first-pass success rate was 88% in the SG and 50% in the CG (p < 0.01). Although ablation parameters were not significantly different, the first-pass success rate was lower in the CG than in the SG. AI-guided CTI may be useful in straight CTIs, but a modified approach might be required for concave CTIs.


2019 ◽  
Vol 30 (11) ◽  
pp. 2414-2419 ◽  
Author(s):  
Tao Zhang ◽  
Yunlong Wang ◽  
Zhihong Han ◽  
Hua Zhao ◽  
Zhuo Liang ◽  
...  

2010 ◽  
Vol 6 (3) ◽  
pp. 66 ◽  
Author(s):  
Carlo Pappone ◽  
Luigi Giannelli ◽  
Vincenzo Santinelli ◽  
◽  
◽  
...  

Innovative technologies are being developed to make current ablation procedures safer and easier. Sometimes conventional ablation catheters cannot easily adapt to anatomical targets, making radiofrequency applications challenging, time consuming or even ineffective. The Cool Flex is a novel, flexible and fully-irrigated tip catheter with an innovative design and various angular orientations to better adapt the ablation tip to the surrounding tissue. Here, peliminary experience with this new ablation catheter is reported in the treatment of different tachyarrhythmias, including slow and accessory pathway ablation, cavotricuspid isthmus-dependent atrial flutter and atrial fibrillation. One or two radiofreqency applications may be sufficient to eliminate the arrhythmogenic substrate in most patients without complications.


EP Europace ◽  
2003 ◽  
Vol 4 (Supplement_2) ◽  
pp. B21-B21
Author(s):  
A. Pastor ◽  
A. Nunez ◽  
A. Martin-Penato ◽  
C. Alonso ◽  
J.-C. Garcia ◽  
...  

2020 ◽  
Vol 36 (6) ◽  
pp. 1045-1050
Author(s):  
Verena Tscholl ◽  
Paul Kamieniarz ◽  
Patrick Nagel ◽  
Ulf Landmesser ◽  
Philipp Attanasio ◽  
...  

EP Europace ◽  
2016 ◽  
Vol 18 (suppl_1) ◽  
pp. i144-i144
Author(s):  
Henry Chubb ◽  
Rashed Karim ◽  
Steven Williams ◽  
James Harrison ◽  
John Whitaker ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document