scholarly journals Parametric-Based Thermodynamic Analysis of Organic Rankine Cycle as Bottoming Cycle for Combined-Cycle Power Plant

Author(s):  
Samiullah Qureshi ◽  
◽  
Abdul Ghafoor Memon ◽  
Abdul Fatah Abbasi ◽  
◽  
...  
2013 ◽  
Vol 597 ◽  
pp. 87-98
Author(s):  
Dariusz Mikielewicz ◽  
Jan Wajs ◽  
Elżbieta Żmuda

A preliminary evaluation has been made of a possibility of bottoming of a conventional Brayton cycle cooperating with the CHP power plant with the organic Rankine cycle installation. Such solution contributes to the possibility of annual operation of that power plant, except of operation only in periods when there is a demand for the heat. Additional benefit would be the fact that an optimized backpressure steam cycle has the advantage of a smaller pressure ratio and therefore a less complex turbine design with smaller final diameter. In addition, a lower superheating temperature is required compared to a condensing steam cycle with the same evaporation pressure. Bottoming ORCs have previously been considered by Chacartegui et al. for combined cycle power plants [ Their main conclusion was that challenges are for the development of this technology in medium and large scale power generation are the development of reliable axial vapour turbines for organic fluids. Another study was made by Angelino et al. to improve the performance of steam power stations [. This paper presents an enhanced approach, as it will be considered here that the ORC installation could be extra-heated with the bleed steam, a concept presented by the authors in [. In such way the efficiency of the bottoming cycle can be increased and an amount of electricity generated increases. A thermodynamic analysis and a comparative study of the cycle efficiency for a simplified steam cycle cooperating with ORC cycle will be presented. The most commonly used organic fluids will be considered, namely R245fa, R134a, toluene, and 2 silicone oils (MM and MDM). Working fluid selection and its application area is being discussed based on fluid properties. The thermal efficiency is mainly determined by the temperature level of the heat source and the condenser conditions. The influence of several process parameters such as turbine inlet and condenser temperature, turbine isentropic efficiency, vapour quality and pressure, use of a regenerator (ORC) will be presented. Finally, some general and economic considerations related to the choice between a steam cycle and ORC are discussed.


Author(s):  
Michael Welch ◽  
Nicola Rossetti

Historically gas turbine power plants have become more efficient and reduced the installed cost/MW by developing larger gas turbines and installing them in combined cycle configuration with a steam turbine. These large gas turbines have been designed to maintain high exhaust gas temperatures to maximise the power generation from the steam turbine and achieve the highest overall electrical efficiencies possible. However, in today’s electricity market, with more emphasis on decentralised power generation, especially in emerging nations, and increasing penetration of intermittent renewable power generation, this solution may not be flexible enough to meet operator demands. An alternative solution to using one or two large gas turbines in a large central combined cycle power plant is to design and install multiple smaller decentralised power plant, based on multiple gas turbines with individual outputs below 100MW, to provide the operational flexibility required and enable this smaller power plant to maintain a high efficiency and low emissions profile over a wide load range. This option helps maintain security of power supplies, as well as providing enhanced operational flexibility through the ability to turn turbines on and off as necessary to match the load demand. The smaller gas turbines though tend not to have been optimised for combined cycle operation, and their exhaust gas temperatures may not be sufficiently high, especially under part load conditions, to generate steam at the conditions needed to achieve a high overall electrical efficiency. ORC technology, thanks to the use of specific organic working fluids, permits efficient exploitation of low temperatures exhaust gas streams, as could be the case for smaller gas turbines, especially when working on poor quality fuels. This paper looks at how a decentralised power plant could be designed using Organic Rankine Cycle (ORC) in place of the conventional steam Rankine Cycle to maximise power generation efficiency and flexibility, while still offering a highly competitive installed cost. Combined cycle power generation utilising ORC technology offers a solution that also has environmental benefits in a water-constrained World. The paper also investigates the differences in plant performance for ORC designs utilising direct heating of the ORC working fluid compared to those using an intermediate thermal oil heating loop, and looks at the challenges involved in connecting multiple gas turbines to a single ORC turbo-generator to keep installed costs to a minimum.


Sign in / Sign up

Export Citation Format

Share Document