scholarly journals In vitro evaluation of self-etch bonding in orthodontics using cyclic fatigue

2011 ◽  
Vol 81 (5) ◽  
pp. 783-787 ◽  
Author(s):  
Ameerah Yousef Mansour ◽  
James L. Drummond ◽  
Carla A. Evans ◽  
Zuhair Bakhsh

Abstract Objective: To evaluate the bond strength of a self-etch bonding system using static loading and cyclic fatigue with shear testing. This is a two-part evaluation; the first part will evaluate shear testing, the second part tensile testing. Materials and Methods: Bovine teeth (n  =  82) were randomly distributed to either a self-etch (Transbond Plus) or total-etch (37% phosphoric-acid + Transbond XT) group. The static shear (SSBS) and cyclic shear (CSBS) bond strengths were measured 24 hours after the bonding of mesh-based brackets. The adhesive remnant index (ARI) and failure sites were evaluated. Results: The mean SSBS was 34.25 ± 9.21 and 24.64 ± 9.42 MPa for the total- and self-etch groups, respectively. CSBS was 24.07 ± 0.65 MPa and 18.92 ± 1.08 MPa for the total- and self-etch groups, respectively. Cyclic loading produced lower bond strengths compared to static testing for both adhesives; the difference was only statistically significant for the total-etch system. Comparison of the two materials showed a statistically significant difference between the two techniques. The total-etch had higher bond strengths than the self-etch bonding system. The samples showed a predominance of ARI scored of 2 and 1, and their bonding failure sites were cohesive within the composite. Conclusion: Cyclic loading, simulating occlusal forces, reduces the bond strength of both bonding systems. Even though the self-etch bonding system had lower shear bond strength than the total-etch system, both were still clinically acceptable.

Author(s):  
Mohammad Moslem Imani ◽  
Farzaneh Aghajani ◽  
Nafiseh Momeni ◽  
Mohammad Sadegh Ahmad Akhoundi

Objectives: In clinical conditions, orthodontic brackets are exposed to periodic stresses mainly induced by mastication and intraoral forces. The objective of the present study was to evaluate the effects of cyclic loading to simulate masticatory forces on shear bond strength (SBS) of metal brackets bonded to teeth using self-etch and total-etch bonding systems. Materials and Methods: Eighty-four caries- and crack-free bovine mandibular incisors were selected and randomly assigned to two groups based on the type of bonding system. After bonding, all samples were thermocycled (500 cycles) followed by cyclic loading of the half of the specimens in each group by applying 40 N load with 2 Hz frequency for 10,000 cycles. The SBS was measured using a universal testing machine. The adhesive remnant index (ARI) score was calculated subsequently. Data were analyzed using Kolmogorov-Smirnov test, two-way ANOVA and Mann-Whitney test. Results: The SBS was 10.09±3.78 MPa and 14.44±6.06 MPa for self-etch and total-etch bonding systems in cyclic loading group, respectively. The SBS was 9.43±5.3 MPa and 11.31±5.42 MPa in self-etch and total-etch groups without cyclic loading, respectively. Cyclic loading did not cause any significant difference in SBS (P>0.05). The ARI scores of the groups were significantly different (P<0.05). Conclusions: The present results demonstrated that low masticatory forces at 10,000 cycles did not have a significant impact on bracket-adhesive SBS; however, they significantly changed the ARI score. Even though the total-etch bonding system yielded higher SBS than the self-etch system, the performance of both was clinically acceptable.


2011 ◽  
Vol 36 (1) ◽  
pp. 86-91 ◽  
Author(s):  
M. Schiltz-Taing ◽  
Y. Wang ◽  
B. Suh ◽  
D. Brown ◽  
L. Chen

Clinical Relevance The effectiveness of self-etch adhesive systems is dependent on both the physical properties of the adhesive and the integrity of the adhesive-dentin interface. Most importantly, the integrity of the adhesive-dentin interface is affected by the tubule orientation of the intaglio dentin structure. The initial bond strength and potential durability of the self-etch adhesive interfaces to dentin are significantly affected by both the adhesive pH and occlusally-oriented tubule direction. The clinical relevance to the dentist is that the results reported for bond strengths by both manufacturers and independent researchers should be interpreted and compared based on the orientation of the dentin used for the measurements, particularly for those adhesives that are very acidic (pH lower than 2).


10.2341/07-42 ◽  
2008 ◽  
Vol 33 (1) ◽  
pp. 79-88 ◽  
Author(s):  
A. D. Loguercio ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
R. T. Patzlaff ◽  
...  

Clinical Relevance The effect of surface preparation was adhesive-dependent. Improvements in resin-enamel bond strength after enamel preparation were observed only for AdheSE and Optibond Solo plus Self-Etch Primer. Among the self-etch systems, mild, self-etch Clearfil SE Bond showed the highest bond strength values. No degradation of resin-enamel bonds was observed after 12 months of water storage, regardless of the adhesive tested.


Author(s):  
Tubayesha Hassan ◽  
MH Sattar

As a means of regular practice in orthodontics and aesthetic dentistry, resin based adhesive systems are being used exclusively. Keeping up with the ever-increasing demand for aesthetic dental treatment all over the world, newer and more improved adhesive systems have been developed. However, regarding the comparison as to which bonding system performs better in clinical perspective, there is lack of existing scientific review articles. In this review, we tend to explore the conventional etch and rinse bonding system and the self-etch primer bonding system. The different tests to assess and compare bond strength between these two types of adhesives from various bibliography are discussed. The results of shear bond strength test, adhesive remnant index (ARI), enamel-adhesive interface using scanning electron microscope (SEM) and the effect of saliva contamination and time are discussed. Interestingly, each system has its strengths and weaknesses. In shear bond strength, self-etch bonding systems clearly exhibits less strength than conventional bonding systems. Resin tags into enamel surface are shorter in self-etch primer adhesives which results from milder etching to enamel compared to the conventional aid-etch and rinse adhesives. Contrarily, the irreversible changes to enamel surface is more aggressive in conventional acid-etching which states that self-etching systems are better according to the principles of minimal intervention dentistry. Ban J Orthod & Dentofac Orthop, April 2017; Vol-7 (1-2), P.20-26


10.2341/08-58 ◽  
2009 ◽  
Vol 34 (2) ◽  
pp. 181-191 ◽  
Author(s):  
A. Reis ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
A. M. Andrade ◽  
...  

Clinical Relevance The improvement of resin-enamel bond strengths after using Si-C paper and diamond burs for enamel preparation is material dependent. No degradation of enamel bond strength could be observed for any one-step self-etch adhesive system after 12 months of water storage.


2006 ◽  
Vol 31 (1) ◽  
pp. 25-32 ◽  
Author(s):  
M. Toledano ◽  
R. Osorio ◽  
A. Albaladejo ◽  
F. S. Aguilera ◽  
F. R. Tay ◽  
...  

Clinical Relevance Resin-dentin bonds, which may have an influence on the long-term success of restorations, are prone to deterioration after cyclic loading. The tested one-step self-etching system (Etch&Prime 3.0) provided the least reliable dentin adhesion. After acid etching of dentin, alcohol/based adhesives performed better than those containing acetone as solvent.


1993 ◽  
Vol 20 (3) ◽  
pp. 225-229 ◽  
Author(s):  
W. H. Sam ◽  
S. Y. Chao ◽  
K. H. Chung

The shear bond strength of two adhesives (Concise® and Dyna-Plus® bonding system) with one type of ceramic bracket was determined in this study. There were statistically significant differences between the bond strengths, with Concisereg; recording higher levels than Dyna-Plus®. Failure sites of Dyna-Plus® were revealed at the enamel/resin, resin/resin, and resin/bracket interfaces; that of the Concise® was mainly at the resin/bracket interface.


2015 ◽  
Vol 16 (5) ◽  
pp. 335-339 ◽  
Author(s):  
Zeeshan H Ahmad ◽  
Sukumaran Anil ◽  
Alaa El Araby ◽  
Mohammad D Al Amri

ABSTRACT Objective To evaluate the influence of Expasyl® gingival retraction paste on the shear bond strength of self-etch and total-etch adhesive systems. Materials and methods Twenty-four specimens of extracted, caries-free, sound human molars were used in this study. The molars were then cut vertically into halves through the buccal and lingual cusps. Forty-eight specimens were divided into four groups (total-etch, total-etch with Expasyl application, self-etch, self-etch with Expasyl application) and the shear bond strength was tested. Results Expasyl significantly reduced the shear bond strength of the self-etch and total-etch adhesive systems. The self-etch system showed relatively lower performance compared with the total-etch adhesive system. The shear bond strength values of the total-etch adhesive without Expasyl showed the highest bond strength (21.48 ± 2.89), while the self-etching group adhesive treated with Expasyl showed the lowest shear bond strength value (14.89 ± 1.81). Conclusion From the observations of this in vitro study, it can be concluded that the use of Expasyl® gingival retraction system can negatively affect bond strength of adhesives. The total-etch system showed better compatibility to the Expasyl gingival retraction system than the self-etch. How to cite this article Al Baker AMA, El Araby A, Al Amri MD, Sukumaran A. The Impact of Expasyl® Gingival Retraction Paste on the Bond Strength of Self-etch and Total-etch Systems. J Contemp Dent Pract 2015;16(5):335-339.


Author(s):  
Masoud Fallahinejad Ghajari ◽  
Mahsa Sheikholeslamian ◽  
Amir Ghasemi ◽  
Leila Simaei

Objectives: This study aimed to determine the microtensile bond strength (μTBS) of a bulk-fill composite to permanent and primary coronal dentin using a universal adhesive in self-etch and total-etch modes. Materials and Methods: This in-vitro study was performed on 52 occlusal dentinal surfaces of human primary and permanent teeth. The crowns were cut to the gingival level. The 48 prepared dentin sections were randomly assigned to the following groups (n=13): A: Primary/Total-etch, B: Primary/Self-etch, C: Permanent/Total-etch, and D: Permanent/Self-etch. In groups A and C, after etching for 15 seconds, two layers of a universal bonding (Futurabond U) were applied and cured for 10 seconds. All samples were filled with a bulk-fill composite (x-trafil; VOCO) and cured for 40 seconds. The samples were cut to a bar-shaped dentin block with the dimensions of 1×1×1 mm3, and after 10,000 thermocycles, the μTBS test was accomplished at a crosshead speed of 1 mm/minute. The mean and standard deviation (SD) of μTBS were calculated, and the data were analyzed using two-way analysis of variance (ANOVA) and Fisher's exact test. Results: The mean μTBS was as follows: A: 15.03±2.0279, B: 11.11±2.4423, C: 23.50±4.8165, and D: 16.26±6.3200 MPa. Futurabond U showed a higher μTBS in the total-etch mode (P<0.001). The permanent teeth had greater μTBS than the primary teeth (P<0.001). Similar percentages of failure modes were observed in the total-etch groups but in the self-etch groups, most failures were in the form of adhesive and mixed. Conclusion: Greater μTBS was observed in the permanent teeth with the total-etch technique.


2019 ◽  
Vol 30 (5) ◽  
pp. 467-475 ◽  
Author(s):  
Gabriela Cardoso de Cardoso ◽  
Leina Nakanishi ◽  
Cristina Pereira Isolan ◽  
Patrícia dos Santos Jardim ◽  
Rafael Ratto de Moraes

Abstract This study evaluated the immediate and 6-month dentin bond strength of universal adhesives used in etch-and-rinse or self-etch bonding strategies. The adhesives tested were Ambar Universal, G-Bond, Single Bond Universal, Tetric N-Bond Universal, and Ybond Universal. Gold standard adhesives (Scotchbond Multipurpose Plus and Clearfil SE Bond) were controls. Microtensile dentin bond strength (n=5 teeth), pH, and C=C conversion (n=3) were evaluated. Data were analyzed at α=0.05. All adhesives showed differences in pH. Ybond had intermediately strong aggressiveness, whereas the others were ultra-mild. The C=C conversion was different in most adhesives. In the etch-and-rinse strategy, all adhesives showed similar results generally except for G-Bond, which had lower bond strength than most adhesives. G-Bond and Tetric-N-Bond showed lower bond strengths after 6 months compared with 24 h, whereas the other adhesives had stable dentin bonds. In the self-etch strategy, G-Bond had lower bond strength than most adhesives. After 6 months, Ambar was the only adhesive showing lower dentin bond strength compared with 24 h. Most adhesives had discreet drops in bond strength during aging when used in the self-etch strategy. The failure modes were also material dependent, with a general pattern of increased adhesive and/or pre-testing failures after storage. In conclusion, the bonding performance of universal adhesives to dentin is material dependent. Most adhesives had stable dentin bonds with results comparable to the gold standard materials, particularly when applied in the self-etch mode. In general, it seems the use of universal adhesives in dentin should not be preceded by phosphoric acid etching.


Sign in / Sign up

Export Citation Format