Five-year Clinical Evaluation of 300 Teeth Restored with Porcelain Laminate Veneers Using Total-etch and a Modified Self-etch Adhesive System

2009 ◽  
Vol 34 (5) ◽  
pp. 516-523 ◽  
Author(s):  
A. Aykor ◽  
E. Ozel

Clinical Relevance Total-etch (Scotchbond Multi-Purpose Plus) and two-step self-etch (AdheSE) adhesive systems were successful in terms of marginal adaptation, cavosurface discoloration, secondary caries, postoperative sensitivity, satisfaction with restoration shade and gingival tissue response in a five-year follow-up.

2009 ◽  
Vol 34 (6) ◽  
pp. 656-663 ◽  
Author(s):  
R. B. Ermis ◽  
O. Kam ◽  
E. U. Celik ◽  
U. B. Temel

Clinical Relevance The two-step etch&rinse and the two-step self-etch adhesive systems tested in this study demonstrated similar clinical performance in Class II cavities after two years.


2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Secil Bektaş Donmez ◽  
Melek D. Turgut ◽  
Serdar Uysal ◽  
Pinar Ozdemir ◽  
Meryem Tekcicek ◽  
...  

The purpose of this study was to assess the clinical performance of composite restorations placed with different adhesive systems in primary teeth. In 32 patients, 128 composite restorations were placed using a split-mouth design as follows (4 groups/patient): three-step etch-and-rinse (Group 1), two-step etch-and-rinse (Group 2), two-step self-etch (Group 3), and one-step self-etch (Group 4). The restorations were clinically evaluated at baseline and at 6, 18, and 36 months according to the FDI criteria. There was no significant difference between the adhesive systems in retention of the restorations (p>0.05). Over time, there was a statistically significant decrease in marginal adaptation in all groups, whereas surface and marginal staining significantly increased in Groups 3 and 4 (p<0.05). The etch-and-rinse adhesive systems resulted in better marginal adaptation than the self-etch adhesive systems (p<0.05). It was concluded that preetching of the primary enamel might help improve the clinical performance of the self-etch adhesive systems in primary teeth.


2011 ◽  
Vol 36 (1) ◽  
pp. 112-115 ◽  
Author(s):  
E. Ozel ◽  
M. Karapinar-Kazandag ◽  
M. Soyman ◽  
G. Bayirli

Clinical Relevance The teeth in this report were restored with a two-step self-etch adhesive system and a microhybrid resin composite. The teeth present with an excellent clinical performance and patient acceptance at the end of a six-year recall.


10.2341/05-55 ◽  
2006 ◽  
Vol 31 (4) ◽  
pp. 450-455 ◽  
Author(s):  
A. M. Guéders ◽  
J. F. Charpentier ◽  
A. I. Albert ◽  
S. O. Geerts

Clinical Relevance This study indicates that etch and rinse adhesive systems are less prone to microleakage than self-etch systems.


10.2341/05-53 ◽  
2006 ◽  
Vol 31 (4) ◽  
pp. 431-441 ◽  
Author(s):  
A. D. Loguercio ◽  
A. Reis ◽  
G. Bortoli ◽  
R. Patzlaft ◽  
S. Kenshima ◽  
...  

Clinical Relevance Etch & rinse systems showed better initial interfacial adaptation than self-etch systems. The differences disappeared after 6-months water storage. The thicker the hybrid layer formed by self-etching adhesives, the lower the immediate gap formation.


2014 ◽  
Vol 62 (4) ◽  
pp. 365-370 ◽  
Author(s):  
Ricardo Alves dos SANTOS ◽  
Eliane Alves de LIMA ◽  
Mônica Maria de Albuquerque PONTES ◽  
Alexandre Batista Lopes do NASCIMENTO ◽  
Marcos Antônio Japiassú Resende MONTES ◽  
...  

OBJECTIVE: To assess the bond strength to dentin of the Single Bond (3M ESPE) and XP Bond (Dentsply) total-etch and Adper SE Plus (3M ESPE) self-etch adhesive systems. METHODS: Fifteen healthy human third molars were randomly allocated across three different groups of five teeth each according to the adhesive system. The occlusal portion of each tooth was removed under refrigeration using a flexible diamond disc (EXTEC, Enfield, CT, USA) down to an area of dentin that did not reveal enamel, as confirmed under a 40X stereo microscope (Ramsor, São Paulo, Brazil). A standardized smear layer was created with #600 grit silicon-carbide paper. The adhesive systems were applied as per manufacturer recommendations, with the exception of the Adper SE Plus system, which was triple-polymerized. Composite resin blocks (5 mm) were placed on the dentin surface. The specimens were stored in distilled water for 24 hours at 37ºC. Using a flexible diamond disc (EXTEC, Enfield, CT, USA), toothpick-like specimens with an adhesive area of less than 1 mm² were obtained. A microtensile bond test was then carried out using a universal testing machine (KRATOS) with a crosshead speed of 0.5 mm/min. Analysis of variance (ANOVA) and Tukey's test were used for comparisons. RESULTS: The bond strength values obtained with each adhesive system were as follows: XP Bond, 96.24 MPa; Adper Single Bond, 72.39 MPa; Adper SE Plus, 49.91 MPa. CONCLUSION: In terms of bond strength to dentin, conventional adhesives outperform self-etching systems.


10.2341/05-20 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 240-247 ◽  
Author(s):  
F. H. O. Mitsui ◽  
A. R. Peris ◽  
A. N. Cavalcanti ◽  
G. M. Marchi ◽  
L. A. F. Pimenta

Clinical Relevance Bond strength is affected by the combination of thermal and mechanical load cycling. However, results vary greatly with the number of mechanical cycles and adhesive system type (total or self-etching).


10.2341/08-58 ◽  
2009 ◽  
Vol 34 (2) ◽  
pp. 181-191 ◽  
Author(s):  
A. Reis ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
A. M. Andrade ◽  
...  

Clinical Relevance The improvement of resin-enamel bond strengths after using Si-C paper and diamond burs for enamel preparation is material dependent. No degradation of enamel bond strength could be observed for any one-step self-etch adhesive system after 12 months of water storage.


2006 ◽  
Vol 31 (1) ◽  
pp. 60-67 ◽  
Author(s):  
B. M. Owens ◽  
W. W. Johnson ◽  
E. F. Harris

Clinical Relevance Decreased leakage was associated with Adper Scotchbond Multi-Purpose (total etch) and iBond (self-etch) systems in Class V resin composite restorations. All adhesive systems performed best when bonded to enamel compared to dentin surface anatomy. Clinicians should be aware that strict adherence to manufacturer instructions, when using these materials, is of primary importance.


10.2341/05-16 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 227-232 ◽  
Author(s):  
S. Deliperi ◽  
D. N. Bardwell ◽  
C. Wegley ◽  
M. D. Congiu

Clinical Relevance Microleakage of a total-etch adhesive system was not influenced by the application of hydrogen peroxide; conversely, enamel dye penetration significantly increased for a self-etching primer.


Sign in / Sign up

Export Citation Format

Share Document