Effect of lower body positive pressure aerobic training on fall risk in patients with diabetic polyneuropathy. Randomized controlled trial

Author(s):  
Ashraf A. ABDELAAL ◽  
Shamekh M. EL-SHAMY
2021 ◽  
Vol 49 (2) ◽  
pp. 030006052098491
Author(s):  
Yan Li ◽  
Qiufen Wei ◽  
Dan Zhao ◽  
Yan Mo ◽  
Liping Yao ◽  
...  

Objective To investigate the effectiveness and safety of non-invasive high-frequency oscillatory ventilation (NHFOV) in post-extubation preterm infants. Methods This was a randomized, controlled trial. A total of 149 preterm infants aged between 25 to 34 weeks’ gestational age with a birth weight of <1500 g who required invasive mechanical ventilation on admission were included. After extubation, they were randomized to the NHFOV group (n = 47), nasal intermittent positive pressure ventilation (NIPPV) group (n = 51), or nasal continuous positive airway pressure (NCPAP) group (n = 51). We compared the effectiveness and safety among these three groups. Results A total of 139 preterm infants finally completed the study. The reintubation rate was significantly lower in the NHFOV group than in the other groups. The duration of non-invasive ventilation and the length of hospital stay in the NHFOV and NIPPV groups were significantly shorter than those in the NCPAP group. The incidence of bronchopulmonary dysplasia in the NHFOV and NIPPV groups was significantly lower than that in the NCPAP group. The NHFOV group had significantly less nasal injury than the NCPAP group. Conclusion As post-extubation respiratory support in preterm infants, NHFOV has a lower reintubation rate compared with NCPAP and NIPPV, without increasing the rate of complications.


Sports ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 51
Author(s):  
Daniel Fleckenstein ◽  
Olaf Ueberschär ◽  
Jan C. Wüstenfeld ◽  
Peter Rüdrich ◽  
Bernd Wolfarth

Lower body positive pressure treadmills (LBPPTs) as a strategy to reduce musculoskeletal load are becoming more common as part of sports conditioning, although the requisite physiological parameters are unclear. To elucidate their role, ten well-trained runners (30.2 ± 3.4 years; VO2max: 60.3 ± 4.2 mL kg−1 min−1) ran at 70% of their individual velocity at VO2max (vVO2max) on a LBPPT at 80% body weight support (80% BWSet) and 90% body weight support (90% BWSet), at 0%, 2% and 7% incline. Oxygen consumption (VO2), heart rate (HR) and blood lactate accumulation (LA) were monitored. It was found that an increase in incline led to increased VO2 values of 6.8 ± 0.8 mL kg−1 min−1 (0% vs. 7%, p < 0.001) and 5.4 ± 0.8 mL kg−1 min−1 (2% vs. 7%, p < 0.001). Between 80% BWSet and 90% BWSet, there were VO2 differences of 3.3 ± 0.2 mL kg−1 min−1 (p < 0.001). HR increased with incline by 12 ± 2 bpm (0% vs. 7%, p < 0.05) and 10 ± 2 bpm (2% vs. 7%, p < 0.05). From 80% BWSet to 90% BWSet, HR increases of 6 ± 1 bpm (p < 0.001) were observed. Additionally, LA values showed differences of 0.10 ± 0.02 mmol l−1 between 80% BWSet and 90% BWSet. Those results suggest that on a LBPPT, a 2% incline (at 70% vVO2max) is not yet sufficient to produce significant physiological changes in VO2, HR and LA—as opposed to running on conventional treadmills, where significant changes are measured. However, a 7% incline increases VO2 and HR significantly. Bringing together physiological and biomechanical factors from previous studies into this practical context, it appears that a 7% incline (at 80% BWSet) may be used to keep VO2 and HR load unchanged as compared to unsupported running, while biomechanical stress is substantially reduced.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2619
Author(s):  
Yoshiaki Kataoka ◽  
Ryo Takeda ◽  
Shigeru Tadano ◽  
Tomoya Ishida ◽  
Yuki Saito ◽  
...  

Recently, treadmills equipped with a lower-body positive-pressure (LBPP) device have been developed to provide precise body weight support (BWS) during walking. Since lower limbs are covered in a waist-high chamber of an LBPP treadmill, a conventional motion analysis using an optical method is impossible to evaluate gait kinematics on LBPP. We have developed a wearable-sensor-based three-dimensional motion analysis system, H-Gait. The purpose of the present study was to investigate the effects of BWS by a LBPP treadmill on gait kinematics using an H-Gait system. Twenty-five healthy subjects walked at 2.5 km/h on a LBPP treadmill under the following three conditions: (1) 0%BWS, (2) 25%BWS and (3) 50%BWS conditions. Acceleration and angular velocity from seven wearable sensors were used to analyze lower limb kinematics during walking. BWS significantly decreased peak angles of hip adduction, knee adduction and ankle dorsiflexion. In particular, the peak knee adduction angle at the 50%BWS significantly decreased compared to at the 25%BWS (p = 0.012) or 0%BWS (p < 0.001). The present study showed that H-Gait system can detect the changes in gait kinematics in response to BWS by a LBPP treadmill and provided a useful clinical application of the H-Gait system to walking exercises.


1992 ◽  
Vol 72 (3) ◽  
pp. 977-984 ◽  
Author(s):  
G. Geelen ◽  
P. Arbeille ◽  
J. L. Saumet ◽  
J. M. Cottet-Emard ◽  
F. Patat ◽  
...  

This study examined the hemodynamic consequences of prolonged lower body positive-pressure application and their relationship to changes in the plasma concentration of the major vasoactive hormones. Six men [36 +/- 2 (SE) yr] underwent 30 min of sitting and then 3 h of 70 degrees head-up tilt. An antigravity suit was applied (60 Torr legs, 30 Torr abdomen) during the last 2 h of tilt. In a similar noninflation experiment, the endocrine responses were measured in the suited subjects tilted for 3 h. Two-dimensional echocardiography was used to calculate ventricular volume and cardiac output. Measurements were made 30 min before and 30 and 90 min after inflation. Immediately after inflation, mean arterial pressure increased by 7 +/- 2 Torr and heart rate decreased by 16 +/- 4 beats/min. Left ventricular end-diastolic volume and systolic volume increased significantly (P less than 0.05) at 30 and 90 min of inflation. Cardiac output increased after 30 min of inflation and returned to the preinflation level at 90 min. Plasma norepinephrine and plasma renin activity were maximally suppressed after 15 and 90 min of inflation, respectively (P less than 0.05). No such hormonal changes occurred during control. Plasma sodium, potassium, and osmolality remained unchanged during both experiments. Thus, prolonged application of lower body positive pressure induces 1) a transient increase in cardiac output and 2) a marked and sustained decrease in plasma norepinephrine and plasma renin activity, which reflect an inflation-induced decrease in sympathetic activity.


2005 ◽  
Vol 37 (Supplement) ◽  
pp. S221
Author(s):  
Masashi Ichinose ◽  
Shigeko Hayashida ◽  
Asami Kitano ◽  
Takeshi Nishiyasu

Sign in / Sign up

Export Citation Format

Share Document