Indoor Relative Positioning Method and Experiment Based on Inertial Measurement Information/Human motion model/UWB Combined System

Author(s):  
Yanshun Zhang ◽  
Nan Wang ◽  
Ming Li ◽  
Xue Sun ◽  
Zhanqing Wang
Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2543
Author(s):  
Marco Caruso ◽  
Angelo Maria Sabatini ◽  
Daniel Laidig ◽  
Thomas Seel ◽  
Marco Knaflitz ◽  
...  

The orientation of a magneto and inertial measurement unit (MIMU) is estimated by means of sensor fusion algorithms (SFAs) thus enabling human motion tracking. However, despite several SFAs implementations proposed over the last decades, there is still a lack of consensus about the best performing SFAs and their accuracy. As suggested by recent literature, the filter parameters play a central role in determining the orientation errors. The aim of this work is to analyze the accuracy of ten SFAs while running under the best possible conditions (i.e., their parameter values are set using the orientation reference) in nine experimental scenarios including three rotation rates and three commercial products. The main finding is that parameter values must be specific for each SFA according to the experimental scenario to avoid errors comparable to those obtained when the default parameter values are used. Overall, when optimally tuned, no statistically significant differences are observed among the different SFAs in all tested experimental scenarios and the absolute errors are included between 3.8 deg and 7.1 deg. Increasing the rotation rate generally leads to a significant performance worsening. Errors are also influenced by the MIMU commercial model. SFA MATLAB implementations have been made available online.


Diagnostics ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 426
Author(s):  
I. Concepción Aranda-Valera ◽  
Antonio Cuesta-Vargas ◽  
Juan L. Garrido-Castro ◽  
Philip V. Gardiner ◽  
Clementina López-Medina ◽  
...  

Portable inertial measurement units (IMUs) are beginning to be used in human motion analysis. These devices can be useful for the evaluation of spinal mobility in individuals with axial spondyloarthritis (axSpA). The objectives of this study were to assess (a) concurrent criterion validity in individuals with axSpA by comparing spinal mobility measured by an IMU sensor-based system vs. optical motion capture as the reference standard; (b) discriminant validity comparing mobility with healthy volunteers; (c) construct validity by comparing mobility results with relevant outcome measures. A total of 70 participants with axSpA and 20 healthy controls were included. Individuals with axSpA completed function and activity questionnaires, and their mobility was measured using conventional metrology for axSpA, an optical motion capture system, and an IMU sensor-based system. The UCOASMI, a metrology index based on measures obtained by motion capture, and the IUCOASMI, the same index using IMU measures, were also calculated. Descriptive and inferential analyses were conducted to show the relationships between outcome measures. There was excellent agreement (ICC > 0.90) between both systems and a significant correlation between the IUCOASMI and conventional metrology (r = 0.91), activity (r = 0.40), function (r = 0.62), quality of life (r = 0.55) and structural change (r = 0.76). This study demonstrates the validity of an IMU system to evaluate spinal mobility in axSpA. These systems are more feasible than optical motion capture systems, and they could be useful in clinical practice.


2019 ◽  
Vol 39 (2-3) ◽  
pp. 250-265 ◽  
Author(s):  
David Fridovich-Keil ◽  
Andrea Bajcsy ◽  
Jaime F Fisac ◽  
Sylvia L Herbert ◽  
Steven Wang ◽  
...  

One of the most difficult challenges in robot motion planning is to account for the behavior of other moving agents, such as humans. Commonly, practitioners employ predictive models to reason about where other agents are going to move. Though there has been much recent work in building predictive models, no model is ever perfect: an agent can always move unexpectedly, in a way that is not predicted or not assigned sufficient probability. In such cases, the robot may plan trajectories that appear safe but, in fact, lead to collision. Rather than trust a model’s predictions blindly, we propose that the robot should use the model’s current predictive accuracy to inform the degree of confidence in its future predictions. This model confidence inference allows us to generate probabilistic motion predictions that exploit modeled structure when the structure successfully explains human motion, and degrade gracefully whenever the human moves unexpectedly. We accomplish this by maintaining a Bayesian belief over a single parameter that governs the variance of our human motion model. We couple this prediction algorithm with a recently proposed robust motion planner and controller to guide the construction of robot trajectories that are, to a good approximation, collision-free with a high, user-specified probability. We provide extensive analysis of the combined approach and its overall safety properties by establishing a connection to reachability analysis, and conclude with a hardware demonstration in which a small quadcopter operates safely in the same space as a human pedestrian.


Author(s):  
Ryan S. McGinnis ◽  
Jessandra Hough ◽  
N. C. Perkins

Newly developed miniature wireless inertial measurement units (IMUs) hold great promise for measuring and analyzing multibody system dynamics. This relatively inexpensive technology enables non-invasive motion tracking in broad applications, including human motion analysis. The second part of this two-part paper advances the use of an array of IMUs to estimate the joint reactions (forces and moments) in multibody systems via inverse dynamic modeling. In particular, this paper reports a benchmark experiment on a double-pendulum that reveals the accuracy of IMU-informed estimates of joint reactions. The estimated reactions are compared to those measured by high precision miniature (6 dof) load cells. Results from ten trials demonstrate that IMU-informed estimates of the three dimensional reaction forces remain within 5.0% RMS of the load cell measurements and with correlation coefficients greater than 0.95 on average. Similarly, the IMU-informed estimates of the three dimensional reaction moments remain within 5.9% RMS of the load cell measurements and with correlation coefficients greater than 0.88 on average. The sensitivity of these estimates to mass center location is discussed. Looking ahead, this benchmarking study supports the promising and broad use of this technology for estimating joint reactions in human motion applications.


2019 ◽  
Vol 13 (4) ◽  
pp. 506-516 ◽  
Author(s):  
Tsubasa Maruyama ◽  
Mitsunori Tada ◽  
Haruki Toda ◽  
◽  

The measurement of human motion is an important aspect of ergonomic mobility design, in which the mobility product is evaluated based on human factors obtained by digital human (DH) technologies. The optical motion-capture (MoCap) system has been widely used for measuring human motion in laboratories. However, it is generally difficult to measure human motion using mobility products in real-world scenarios, e.g., riding a bicycle on an outdoor slope, owing to unstable lighting conditions and camera arrangements. On the other hand, the inertial-measurement-unit (IMU)-based MoCap system does not require any optical devices, providing the potential for measuring riding motion even in outdoor environments. However, in general, the estimated motion is not necessarily accurate as there are many errors due to the nature of the IMU itself, such as drift and calibration errors. Thus, it is infeasible to apply the IMU-based system to riding motion estimation. In this study, we develop a new riding MoCap system using IMUs. The proposed system estimates product and human riding motions by combining the IMU orientation with contact constraints between the product and DH, e.g., DH hands in contact with handles. The proposed system is demonstrated with a bicycle ergometer, including the handles, seat, backrest, and foot pedals, as in general mobility products. The proposed system is further validated by comparing the estimated joint angles and positions with those of the optical MoCap for three different subjects. The experiment reveals both the effectiveness and limitations of the proposed system. It is confirmed that the proposed system improves the joint position estimation accuracy compared with a system using only IMUs. The angle estimation accuracy is also improved for near joints. However, it is observed that the angle accuracy decreases for a few joints. This is explained by the fact that the proposed system modifies the orientations of all body segments to satisfy the contact constraints, even if the orientations of a few joints are correct. This further confirms that the elapsed time using the proposed system is sufficient for real-time application.


Sign in / Sign up

Export Citation Format

Share Document