scholarly journals Effect of Utility Voltage Distortion on the Performance of Different Control Strategies for Shunt Active Power Filter

2017 ◽  
Vol 2 (8) ◽  
pp. 27
Author(s):  
Ahmed Mohammed Attiya Soliman ◽  
Salah Kamal El-Sayed ◽  
M. A. Mehanna

The widespread use of power electronics in industrial, commercial and even residential electrical equipment like non-linear loads causes deterioration of the quality of the electric power supply with distortion of the supply voltage and in order to mitigate this quality the shunt active power filter (SAPF) is the suitable and effective solution for harmonic elimination and reactive power compensation and lead to power quality (PQ) improvement, therefor an effective and accurate current control technique is needed in order for a SAPF where control algorithm is the heart for SAPF to perform this function and its dynamic performance is mainly depends on these control strategy. This paper proposes three different current control strategies (CCS) based on instantaneous power theory and generalized fryze theory which used for the generation or extraction of the accurate reference current signals which comparing with the actual signals through hysteresis current technique (HCT) to produce suitable gating signals for SAPF and discusses the performance for these controllers when the supply bus voltage is distorted with scope on the efficient control algorithm. Matlab / Simulink simulation results are presented to validate the control strategy and demonstrate the effectiveness of SAPF to provide mitigation of power quality problems for non-linear load to reach an acceptable value comply with recommended standards.

2014 ◽  
Vol 573 ◽  
pp. 59-65
Author(s):  
B.S. Nalina ◽  
V.J. Vijayalakshmi

Nowadays the number of non linear loads in power systems is increasing dramatically. These non linear loads inject harmonic currents and voltage which makes the supply currents non-sinusoidal. These harmonics are eliminated via an active power filter. The reference currents are generated by shunt active filter which is provided to compensate harmonic currents demanded by the load. Different current control strategies are implemented to improve the performance of shunt active power filter. These techniques are useful in making the supply currents sinusoidal. The performance of the current control techniques are different from each other. The %THD can be reduced with the aid of shunt active power filter. In this paper, different current control schemes are analyzed and their outputs are compared to determine the effectiveness. The most effective current controller generates less %THD. The power quality of the system is improved with the reduction of %THD. The different current controllers which are compared in this paper are GA controller and PI-VPI controller.Under analysis, the PI-VPI controller is found to be effective.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1951
Author(s):  
Mihaela Popescu ◽  
Alexandru Bitoleanu ◽  
Mihaita Linca ◽  
Constantin Vlad Suru

This paper presents the use of a three-phase four-wire shunt active power filter to improve the power quality in the Department of Industrial Electronics of a large enterprise from Romania. The specificity is given by the predominant existence of single-phase consumers (such as personal computers, printers, lighting and AC equipment). In order to identify the power quality indicators and ways to improve them, an A-class analyzer was used to record the electrical quantities and energy parameters in the point of common coupling (PCC) with the nonlinear loads for 27 h. The analysis shows that, in order to improve the power quality in PCC, three goals must be achieved: the compensation of the distortion power, the compensation of the reactive power and the compensation of the load unbalance. By using the conceived three-leg shunt active power filter, controlled through the indirect current control method in an original variant, the power quality at the supply side is very much improved. In the proposed control algorithm, the prescribed active current is obtained as a sum of the loss current provided by the DC voltage and the equivalent active current of the unbalanced load. The performance associated with each objective of the compensation is presented and analyzed. The results show that all the power quality indicators meet the specific standards and regulations and prove the validity of the proposed solution.


Author(s):  
P. Thirumoorthi ◽  
Raheni T D

Power system harmonics are a menace to electric power system with disastrous consequence. Due to the presence of non linear load, power quality of the system gets affected.  To overcome this, shunt active power filter have been used near harmonic producing loads or at the point of common coupling to block current harmonics. The shunt active power filter is designed to minimize harmonics in source current and reactive power in the non linear power supplies which are creating harmonics. In this paper, Instantaneous power of p-q theory is employed to generate the reference currents and PI controller is used to control the dc link voltage. In addition to this, Artificial Intelligence (AI) technique is used to minimize the harmonics produced by nonlinear load. The main objective of this paper is to analyze and compare THD of the source current with PI controller and by artificial neural network based back propagation algorithm. The proposed system is designed with MATLAB/SIMULINK environment.


This paper presents the simulation-based study and results of a three-phase shunt active power filter (SAPF) for power quality improvement. The power quality of the power systems is degraded because of the presence of non-linear loads at the consumer end. The SAPF can reduce the impact of harmonics caused by the non-linear loads. The analyzed SAPF system is modeled and simulated using MATLAB-Simulink workspace. The ultimate goal of this study is to improve the total harmonic distortion of the system as per the standards defined by IEEE-519.