scholarly journals An Efficient Approach for Reactive Power Compensation of Distribution Networks Using Particle Swarm Optimization

2020 ◽  
Vol 6 (7) ◽  
pp. 14-19
Author(s):  
Nikhil Dubey ◽  
Prof. Ranvijay

The power compensation is the one of the problem in distribution network. The power compensation is done by maintain the reactive power in distribution network. The power is maintain the state of the UPQC (Uni?ed power quality conditioner). The UPAC controlled by the STATCOM or DSTATCOM. Different approaches use to maintain the power at needed level in the power distribution network the process done by MOPSO optimization method the MOPSO is the best for this process because we consider the lot of objective function to optimize the place of the UPQC. In our proposed work we find the power level in distribution network using optimization algorithm. The optimization algorithm is used to optimization the power and find which place is suitable for place the STATCOM or DSTATCOM. This is used to maintain the reactive power in distribution network.

2014 ◽  
Vol 960-961 ◽  
pp. 1077-1080 ◽  
Author(s):  
Bo Lun Wang

Near the load of distribution network access distributed networks, the entire distribution network load distribution will change, system trend then change, then the trend of the distribution network can also be changed from the original "one-way flow" to "two-way flow". For synchronous generator connected to the power distribution network, the input active power and reactive power at the same time to the system, can reduce the loss and the voltage distribution network can play a supporting role, but for asynchronous induction generator connected to the power distribution network, the input to the system active power and reactive power absorption, reduce the power factor of the grid. By trend analysis found that introducing asynchronous induction generator to increase distribution network loss, deterioration in transmission line voltage level. Distributed generators after introducing the distribution network could reduce may also increase the system network loss.


Author(s):  
Xin Shen ◽  
Hongchun Shu ◽  
Min Cao ◽  
Nan Pan ◽  
Junbin Qian

In distribution networks with distributed power supplies, distributed power supplies can also be used as backup power sources to support the grid. If a distribution network contains multiple distributed power sources, the distribution network becomes a complex power grid with multiple power supplies. When a short-circuit fault occurs at a certain point on the power distribution network, the size, direction and duration of the short-circuit current are no longer single due to the existence of distributed power, and will vary with the location and capacity of the distributed power supply system. The change, in turn, affects the current in the grid, resulting in the generation and propagation of additional current. This power grid of power electronics will cause problems such as excessive standard mis-operation, abnormal heating of the converter and component burnout, and communication system failure. It is of great and practical significance to study the influence of distributed power in distributed power distribution networks.


2018 ◽  
Vol 20 (4) ◽  
pp. 417-429 ◽  
Author(s):  
Satyabrata Dash ◽  
Sukanta Dey ◽  
Deepak Joshi ◽  
Gaurav Trivedi

Purpose The purpose of this paper is to demonstrate the application of river formation dynamics to size the widths of power distribution network for very large-scale integration designs so that the wire area required by power rails is minimized. The area minimization problem is transformed into a single objective optimization problem subject to various design constraints, such as IR drop and electromigration constraints. Design/methodology/approach The minimization process is carried out using river formation dynamics heuristic. The random probabilistic search strategy of river formation dynamics heuristic is used to advance through stringent design requirements to minimize the wire area of an over-designed power distribution network. Findings A number of experiments are performed on several power distribution benchmarks to demonstrate the effectiveness of river formation dynamics heuristic. It is observed that the river formation dynamics heuristic outperforms other standard optimization techniques in most cases, and a power distribution network having 16 million nodes is successfully designed for optimal wire area using river formation dynamics. Originality/value Although many research works are presented in the literature to minimize wire area of power distribution network, these research works convey little idea on optimizing very large-scale power distribution networks (i.e. networks having more than four million nodes) using an automated environment. The originality in this research is the illustration of an automated environment equipped with an efficient optimization technique based on random probabilistic movement of water drops in solving very large-scale power distribution networks without sacrificing accuracy and additional computational cost. Based on the computation of river formation dynamics, the knowledge of minimum area bounded by optimum IR drop value can be of significant advantage in reduction of routable space and in system performance improvement.


2021 ◽  
Author(s):  
Chinmay Shah ◽  
Richard Wies

The conventional power distribution network is being transformed drastically due to high penetration of renewable energy sources (RES) and energy storage. The optimal scheduling and dispatch is important to better harness the energy from intermittent RES. Traditional centralized optimization techniques limit the size of the problem and hence distributed techniques are adopted. The distributed optimization technique partitions the power distribution network into sub-networks which solves the local sub problem and exchanges information with the neighboring sub-networks for the global update. This paper presents an adaptive spectral graph partitioning algorithm based on vertex migration while maintaining computational load balanced for synchronization, active power balance and sub-network resiliency. The parameters that define the resiliency metrics of power distribution networks are discussed and leveraged for better operation of sub-networks in grid connected mode as well as islanded mode. The adaptive partition of the IEEE 123-bus network into resilient sub-networks is demonstrated in this paper.


2014 ◽  
Vol 530-531 ◽  
pp. 353-356
Author(s):  
Run Sheng Li

Due to the high ground fault resistance and the complexity of power distribution network structure (such as too many nodes, branches and too long lines), adopting common traveling wave method and ac injection method can not effectively locate the single-phase grounding fault in the distribution network system.To solve above problems and determine the position of the point of failure prisely, this paper adopted the dc location method of injecting the dc signal from the point of failure under the power outage offline. This paper introduces the single phase dc method and the method of three phase dc, and the simulation shows that the dc location method is effective and feasible.


2014 ◽  
Vol 668-669 ◽  
pp. 749-752 ◽  
Author(s):  
Xiao Yi Zhou ◽  
Ling Yun Wang ◽  
Wen Yue Liang ◽  
Li Zhou

Distributed generation (DG) has an important influence on the voltage of active distribution networks. A unidirectional power distribution network will be transformed into a bidirectional, multiple power supply distribution network after DGs access to the distribution network and the direction of power flow is also changed. Considering the traditional forward and backward substitution algorithm can only deal with the equilibrium node and PQ nodes, so the other types of DGs should be transformed into PQ nodes, then its impact on active distribution network can be analyzed via the forward and backward substitution algorithm. In this paper, the characteristics of active distribution networks are analyzed firstly and a novel approach is proposed to convert PI nodes into PQ nodes. Finally, a novel forward and backward substitution algorithm is adopted to calculate the power flow of the active distribution network with DGs. Extensive validation of IEEE 18 and 33 nodes distribution system indicates that this method is feasible. Numerical results show that when DG is accessed to the appropriate location with proper capacity, it has a significant capability to support the voltages level of distribution system.


2015 ◽  
Vol 734 ◽  
pp. 701-706
Author(s):  
Xian Bin Dai

as the basic method used to analyze the stability of nonlinear dynamic system, it is able to more deeply discuss the stability problems of power system in the vicinity of a critical point in comparison with traditional analysis method. Active power distribution network is a complicated nonlinear dynamic system. The change of voltage stability is the process to convert from stable status to bifurcation in essence. Taking 10-node active distribution system as an example, the author studies the influence of reactive power optimization on voltage stability based on bifurcation theory. The author explains the reactive optimization algorithm based on numerical simulation, namely, it is the decision - making algorithm in order to realize multiple purposes of having minimum power network loss, largest reactive power margin with stable operation of power distribution network and minimum voltage floating in system fluctuation, which is proved to be effective in elevating power distribution system stability, reducing power loss and improving voltage quality.


Author(s):  
Satya PRAKASH ◽  
Manoj HANS ◽  
Vikas THORAT

The power distribution network has grown complex and vulnerable as it increases its demand. The system's reliability has become a prominent factor for the end-users, although the continuity of supply in the distribution network still remains a challenge. In order to achieve the same distribution, automation came into the picture. The term “Distribution Automation” usually refers to an advanced switching system, which works as a subsystem of the existing network. The purpose of the subsystem is to offer real-time observation and control in distribution networks and electricity market operations. Consequently, the development of an autonomous system for isolating failures and restoring power for the distribution of LV (low voltage)/MV (medium voltage) can be an attractive solution for improving energy facilities' reliability. Advanced management techniques are devices and algorithms used to analyze, diagnose, and predict conditions in a distribution network, as well as to identify and take appropriate corrective actions to eliminate, mitigate, and prevent power outages and power quality problems. To demonstrate the model, we used a PIC16F877, CT microcontroller, and a power supply unit.


Sign in / Sign up

Export Citation Format