Effect of Bass Bar Tension on Modal Parameters of a Violin's Top Plate

2015 ◽  
Vol 39 (1) ◽  
pp. 145-149 ◽  
Author(s):  
Ewa B. Skrodzka ◽  
Bogumił B.J. Linde ◽  
Antoni Krupa

Abstract Experimental modal analysis of a violin with three different tensions of a bass bar has been performed. The bass bar tension is the only intentionally introduced modification of the instrument. The aim of the study was to find differences and similarities between top plate modal parameters determined by a bass bar perfectly fitting the shape of the top plate, the bass bar with a tension usually applied by luthiers (normal), and the tension higher than the normal value. In the modal analysis four signature modes are taken into account. Bass bar tension does not change the sequence of mode shapes. Changes in modal damping are insignificant. An increase in bass bar tension causes an increase in modal frequencies A0 and B(1+) and does not change the frequencies of modes CBR and B(1-).

Author(s):  
Horst Irretier ◽  
Frank Reuter

Abstract A completely non-contact testing technique is presented to perform experimental modal analysis on rotating disk systems to identify modal parameters as eigenfrequencies, modal damping ratios and mode shapes due to rotation. Theoretical frequency response functions of rotating structures are presented which form the basis of the modal analysis. Experimental results of a rotating circular disk and a rotating radial impeller are presented and the influence of rotation on the modal parameters due to centrifugal, gyroscopic and aerodynamic effects is shown.


2018 ◽  
Vol 1 (1) ◽  
pp. 16-23 ◽  
Author(s):  
Siva Sankara Babu Chinka ◽  
Balakrishna Adavi ◽  
Srinivasa Rao Putti

In this paper, the dynamic behavior of a cantilever beam without and with crack is observed. An elastic Aluminum cantilever beams having surface crack at various crack positions are considered to analyze dynamically. Crack depth, crack length and crack location are the foremost parameters for describing the health condition of beam in terms of modal parameters such as natural frequency, mode shape and damping ratio. It is crucial to study the influence of crack depth and crack location on modal parameters of the beam for the decent performance and its safety. Crack or damage of structure causes a reduction in stiffness, an intrinsic reduction in resonant frequencies, variation of damping ratios and mode shapes. The broad examination of cantilever beam without crack and with crack has been done using Numerical analysis (Ansys18.0) and experimental modal analysis. To observe the exact higher modes of beam, discretize the beam into small elements. An experimental set up was established for cantilever beam having crack and it was excited by an impact hammer and finally the response was obtained using PCB accelerometer with the help sound and vibration toolkit of NI Lab-view. After obtaining the Frequency response functions (FRFs), the natural frequencies of beam are estimated using peak search method. The effectiveness of experimental modal analysis in terms of natural frequency is validated with numerical analysis results. This paper contains the study of free vibration analysis under the influence of crack at different points along the length of the beam.


2017 ◽  
Vol 42 (1) ◽  
pp. 23-28 ◽  
Author(s):  
Przemysław Mania ◽  
Ewa Fabisiak ◽  
Ewa Skrodzka

AbstractResults of experimental modal analysis of a resonance and non-resonance spruce wood (Picea abies L.) are presented. The resonance wood came from a tree from Poland and Bosnia and Herzegovina, while the non-resonance wood came from the vicinity of Olsztyn from the north-eastern Poland. The modal parameters (modal frequency, modal damping and mode shapes) of the wood samples were determined for the samples of 8 mm in thickness. Modal analysis was made by pulse excitation. The resonance and non-resonance wood differ in the fundamental modal parameters as well as in the number of potential modes. Additionally, calculated values of damping factor are presented. The values are much bigger for a non-resonance wood than for good quality resonance spruce.


2010 ◽  
Vol 139-141 ◽  
pp. 2423-2426
Author(s):  
Lian Wan Zhang ◽  
Zhong Jun Yin ◽  
Bing Chen ◽  
Zhi Chao Tang ◽  
Zheng Tian

The LMS Test.Lab system was used to carried out experimental modal analysis of large vibratory feeder, the PloyMAX method was employed to estimate and identify the modal parameter of vibratory feeder and the modal parameters such as modal frequencies, modal damping ratios and mode shape at concerned band were got; Compared the results of experimental modal analysis to the results of finite element method, the results show that the experimental modal analysis and finite element analysis was consistent to some extent, verified the correctness of finite element model; the bias between experimental and theoretical is inevitable, the experimental results are more reliable relative to the actual and better reflect the dynamic characteristics of vibratory feeder, which will be provided as the reference for dynamic design and dynamic improvement of the vibratory feeder.


2013 ◽  
Vol 38 (1) ◽  
pp. 75-81 ◽  
Author(s):  
Ewa B. Skrodzka ◽  
Bogumił B.J. Linde ◽  
Antoni Krupa

Abstract Two violins were investigated. The only intentionally introduced difference between them was the type of varnish. One of the instruments was covered with a spirit varnish, the other was oil varnished. Experimental modal analysis was done for unvarnished/varnished violins and a questionnaire inquiry on the instrument’s sound quality was performed. The aim of both examinations was to find differences and similarities between the two instruments in the objective (modal parameters) and subjective domain (subjective evaluation of sound quality). In the modal analysis, three strongly radiating signature modes were taken into account. Varnishing did not change the sequence of mode shapes. Modal frequencies A0 and B(1+) were not changed by oil varnishing compared to the unvarnished condition. For the oil varnished instrument, the frequency of mode B(1+) was lower than that of the same mode of the spirit varnished instrument. Our two violins were not excellent instruments, but before varnishing they were practically identical. However, after varnishing it appeared that the oil-varnished violin was better than the spirit-varnished instrument. Therefore, it can be assumed with a fairly high probability that also in general, the oil-varnished violins sound somewhat better than initially identical spirit-varnished ones.


Crystals ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 311
Author(s):  
Chan-Jung Kim

Previous studies have demonstrated the sensitivity of the dynamic behavior of carbon-fiber-reinforced plastic (CFRP) material over the carbon fiber direction by performing uniaxial excitation tests on a simple specimen. However, the variations in modal parameters (damping coefficient and resonance frequency) over the direction of carbon fiber have been partially explained in previous studies because all modal parameters have only been calculated using the representative summed frequency response function without modal analysis. In this study, the dynamic behavior of CFRP specimens was identified from experimental modal analysis and compared five CFRP specimens (carbon fiber direction: 0°, 30°, 45°, 60°, and 90°) and an isotropic SCS13A specimen using the modal assurance criterion. The first four modes were derived from the SCS13A specimen; they were used as reference modes after verifying with the analysis results from a finite element model. Most of the four mode shapes were found in all CFRP specimens, and the similarity increased when the carbon fiber direction was more than 45°. The anisotropic nature was dominant in three cases of carbon fiber, from 0° to 45°, and the most sensitive case was found in Specimen #3.


2013 ◽  
Vol 486 ◽  
pp. 36-41 ◽  
Author(s):  
Róbert Huňady ◽  
František Trebuňa ◽  
Martin Hagara ◽  
Martin Schrötter

Experimental modal analysis is a relatively young part of dynamics, which deals with the vibration modes identification of machines or their parts. Its development has started since the beginning of the eighties, when the computers hardware equipment has improved and the fast Fourier transform (FFT) could be used for the results determination. Nowadays it provides an uncountable set of vibration analysis possibilities starting with conventional contact transducers of acceleration and ending with modern noncontact optical methods. In this contribution we mention the use of high-speed digital image correlation by experimental determination of mode shapes and modal frequencies. The aim of our work is to create a program application called Modan 3D enabling the performing of experimental modal analysis and operational modal analysis. In this paper the experimental modal analysis of a thin steel sample performed with Q-450 Dantec Dynamics is described. In Modan 3D the experiment data were processed and the vibration modes were determined. The reached results were verified by PULSE modulus specialized for mechanical vibration analysis.


This article presents a critical review of recent research done on crack identification and localization in structural beams using numerical and experimental modal analysis. Crack identification and localization in beams are very crucial in various engineering applications such as ship propeller shafts, aircraft wings, gantry cranes, and Turbo machinery blades. It is necessary to identify the damage in time; otherwise, there may be serious consequences like a catastrophic failure of the engineering structures. Experimental modal analysis is used to study the vibration characteristics of structures like natural frequency, damping and mode shapes. The modal parameters like natural frequency and mode shapes of undamaged and damaged beams are different. Based on this reason, structural damage can be detected, especially in beams. From the review of various research papers, it is identified that a lot of the research done on beams with open transverse crack. Crack location is identified by tracking variation in natural frequencies of a healthy and cracked beam


2019 ◽  
Vol 11 (2) ◽  
pp. 324-337
Author(s):  
Sk Abdul Kaium ◽  
Sayed Abul Hossain ◽  
Jafar Sadak Ali

Purpose The purpose of this paper is to highlight that the need for improved system identification methods within the domain of modal analysis increases under the impulse of the broadening field of applications, e.g., damage detection and vibro-acoustics, and the increased complexity of today’s structures. Although significant research efforts during the last two decades have resulted in an extensive number of parametric identification algorithms, most of them are certainly not directly applicable for modal parameter extraction. So, based on this, the aim of the present work is to develop a technique for modal parameter extraction from the measured signal. Design/methodology/approach A survey and classification of the different modal analysis methods are made; however, the focus of this thesis is placed on modal parameter extraction from measured time signal. Some of the methods are examined in detail, including both single-degree-of-freedom and multi-degree-of-freedom approaches using single and global frequency-response analysis concepts. The theory behind each of these various analysis methods is presented in depth, together with the development of computer programs, theoretical and experimental examples and discussion, in order to evaluate the capabilities of those methods. The problem of identifying properties of structures that possess close modes is treated in particular detail, as this is a difficult situation to handle and yet a very common one in many structures. It is essential to obtain a good model for the behavior of the structure in order to pursue various applications of experimental modal analysis (EMA), namely: updating of finite element models, structural modification, subsystem-coupling and calculation of real modes from complex modes, to name a few. This last topic is particularly important for the validation of finite element models, and for this reason, a number of different methods to calculate real modes from complex modes are presented and discussed in this paper. Findings In this paper, Modal parameters like mode shapes and natural frequencies are extracted using an FFT analyzer and with the help of ARTeMiS, and subsequently, an algorithm has been developed based on frequency domain decomposition (FDD) technique to check the accuracy of the results as obtained from ARTeMiS. It is observed that the frequency domain-based algorithm shows good agreement with the extracted results. Hence the following conclusion may be drawn: among several frequency domain-based algorithms for modal parameter extraction, the FDD technique is more reliable and it shows a very good agreement with the experimental results. Research limitations/implications In the case of extraction techniques using measured data in the frequency domain, it is reported that the model using derivatives of modal parameters performed better in many situations. Lack of accurate and repeatable dynamic response measurements on complex structures in a real-life situation is a challenging problem to analyze exact modal parameters. Practical implications During the last two decades, there has been a growing interest in the domain of modal analysis. Evolved from a simple technique for troubleshooting, modal analysis has become an established technique to analyze the dynamical behavior of complex mechanical structures. Important examples are found in the automotive (cars, trucks, motorcycles), railway, maritime, aerospace (aircrafts, satellites, space shuttle), civil (bridges, buildings, offshore platforms) and heavy equipment industry. Social implications Presently structural health monitoring has become a significantly important issue in the area of structural engineering particularly in the context of safety and future usefulness of a structure. A lot of research is being carried out in this area incorporating the modern sophisticated instrumentations and efficient numerical techniques. The dynamic approach is mostly employed to detect structural damage, due to its inherent advantage of having global and location-independent responses. EMA has been attempted by many researchers in a controlled laboratory environment. However, measuring input excitation force(s) seems to be very expensive and difficult for the health assessment of an existing real-life structure. So Ambient Vibration Analysis is a good alternative to overcome those difficulties associated with the measurement of input excitation force. Originality/value Three single bay two storey frame structure has been chosen for the experiment. The frame has been divided into six small elements. An algorithm has been developed to determine the natural frequency of those frame structures of which one is undamaged and the rest two damages in single element and double element, respectively. The experimental results from ARTeMIS and from developed algorithm have been compared to verify the effectiveness of the developed algorithm. Modal parameters like mode shapes and natural frequencies are extracted using an FFT analyzer and with the help of ARTeMiS, and subsequently, an algorithm has been programmed in MATLAB based on the FDD technique to check the accuracy of the results as obtained from ARTeMiS. Using singular value decomposition, the power Spectral density function matrix is decomposed using the MATLAB program. It is observed that the frequency domain-based algorithm shows good consistency with the extracted results.


Sign in / Sign up

Export Citation Format

Share Document