scholarly journals Solar Assisted Ground Source Heat Pump Performance in Nearly Zero Energy Building in Baltic Countries

Author(s):  
Karolis Januševičius ◽  
Giedrė Streckienė

Abstract In near zero energy buildings (NZEB) built in Baltic countries, heat production systems meet the challenge of large share domestic hot water demand and high required heating capacity. Due to passive solar design, cooling demand in residential buildings also needs an assessment and solution. Heat pump systems are a widespread solution to reduce energy use. A combination of heat pump and solar thermal collectors helps to meet standard requirements and increases the share of renewable energy use in total energy balance of country. The presented paper describes a simulation study of solar assisted heat pump systems carried out in TRNSYS. The purpose of this simulation was to investigate how the performance of a solar assisted heat pump combination varies in near zero energy building. Results of three systems were compared to autonomous (independent) systems simulated performance. Different solar assisted heat pump design solutions with serial and parallel solar thermal collector connections to the heat pump loop were modelled and a passive cooling possibility was assessed. Simulations were performed for three Baltic countries: Lithuania, Latvia and Estonia.

2019 ◽  
Vol 6 (1) ◽  
Author(s):  
Frederick Paige ◽  
Philip Agee ◽  
Farrokh Jazizadeh

AbstractThe behaviors of building occupants have continued to perplex scholars for years in our attempts to develop models for energy efficient housing. Building simulations, project delivery approaches, policies, and more have fell short of their optimistic goals due to the complexity of human behavior. As a part of a multiphase longitudinal affordable housing study, this dataset represents energy and occupant behavior attributes for 6 affordable housing units over nine months in Virginia, USA which are not performing to the net-zero energy standard they were designed for. This dataset provides researchers the ability to analyze the following variables: energy performance, occupant behaviors, energy literacy, and ecological perceptions. Energy data is provided at a 1 Hz sampling rate for four circuits: main, hot water heater, dryer, and HVAC. Building specifications, occupancy, weather data, and neighboring building energy use data are provided to add depth to the dataset. This dataset can be used to update building energy use models, predictive maintenance, policy frameworks, construction risk models, economic models, and more.


2021 ◽  
Author(s):  
Mohammad Reza Bahrami

Nowadays, one of the global problems is climate change. Commercial and residential buildings are among the most powerful consumers of energy. The energy consumption of buildings increases because of the development of the residents’ needs. Zero Energy Building uses renewable energy sources therefore Zero Energy Buildings have advantages in the field of environmental care because of the mitigation of CO2 emissions and the decrease of energy use in the building sector. The deposits of fossil fuel deplete at a high rate. The new deposits are extremely hard to find and if they are discovered are smaller than already used ones. Therefore, Zero Energy Buildings are the solution for this problem because they do not depend on fuel.


2021 ◽  
Author(s):  
◽  
Dekhani Juvenalis Dukakis Nsaliwa

<p>In most developed economies, buildings are directly and indirectly accountable for at least 40% of the final energy use. Consequently, most world cities are increasingly surpassing sensitive environmental boundaries and continue to reach critical biophysical thresholds. Climate change is one of the biggest threats humanity faces today and there is an urgent need to reduce energy use and CO₂ emissions globally to zero or to less than zero, to address climate change. This often leads to the assumption that buildings must reduce energy demand and emit radically less CO₂ during construction and occupation periods. Certainly, this is often implemented through delivering ‘zero energy buildings’. The deployment of residential buildings which meet the zero energy criteria thereby allowing neighbourhoods and cities to convert to semi-autonomous energy systems is seen to have a promising potential for reducing and even eliminating energy demand and the associated greenhouse gas emissions. However, most current zero energy building approaches focus solely on operational energy overlooking other energy uses such as embodied energy and user transport energy. Embodied energy constitutes all energy requirements for manufacturing building materials, construction and replacement. Transport energy comprises the amount of energy required to provide mobility services to building users.  Zero energy building design decisions based on partial evaluation and quantification approaches might result in an increased energy demand at different or multiple scales of the built environment. Indeed, recent studies have demonstrated that embodied and transport energy demands account for more than half of the total annual energy demand of residential buildings built based on zero energy criteria. Current zero energy building frameworks, tools and policies therefore may overlook more than ~80% of the total net energy balance annually.  The original contribution of this thesis is an integrated multi-scale zero energy building framework which has the capacity to gauge the relative effectiveness towards the deployment of zero energy residential buildings and neighbourhoods. This framework takes into account energy requirements and CO₂ emissions at the building scale, i.e. the embodied energy and operation energy demands, and at the city scale, i.e. the embodied energy of related transport modes including infrastructure and the transport operational energy demand of its users. This framework is implemented through the development of a quantification methodology which allows the analysis and evaluation of energy demand and CO₂ emissions pertaining to the deployment of zero energy residential buildings and districts. A case study, located in Auckland, New Zealand is used to verify, validate and investigate the potential of the developed framework.  Results confirm that each of the building (embodied and operational) and transport (embodied and operational) energy requirements represent a very significant share of the annual overall energy demand and associated CO₂ emissions of zero energy buildings. Consequently, rather than the respect of achieving a net zero energy building balance at the building scale, the research has revealed that it is more important, above all, to minimise building user-related and transportation energy demand at the city scale and maximise renewable energy production coupled with efficiency improvements at grid level. The application of the developed evaluation framework will enable building designers, urban planners, researchers and policy makers to deliver effective multi-scale zero energy building strategies which will ultimately contribute to reducing the overall environmental impact of the built environment today.</p>


2021 ◽  
Author(s):  
◽  
Dekhani Juvenalis Dukakis Nsaliwa

<p>In most developed economies, buildings are directly and indirectly accountable for at least 40% of the final energy use. Consequently, most world cities are increasingly surpassing sensitive environmental boundaries and continue to reach critical biophysical thresholds. Climate change is one of the biggest threats humanity faces today and there is an urgent need to reduce energy use and CO₂ emissions globally to zero or to less than zero, to address climate change. This often leads to the assumption that buildings must reduce energy demand and emit radically less CO₂ during construction and occupation periods. Certainly, this is often implemented through delivering ‘zero energy buildings’. The deployment of residential buildings which meet the zero energy criteria thereby allowing neighbourhoods and cities to convert to semi-autonomous energy systems is seen to have a promising potential for reducing and even eliminating energy demand and the associated greenhouse gas emissions. However, most current zero energy building approaches focus solely on operational energy overlooking other energy uses such as embodied energy and user transport energy. Embodied energy constitutes all energy requirements for manufacturing building materials, construction and replacement. Transport energy comprises the amount of energy required to provide mobility services to building users.  Zero energy building design decisions based on partial evaluation and quantification approaches might result in an increased energy demand at different or multiple scales of the built environment. Indeed, recent studies have demonstrated that embodied and transport energy demands account for more than half of the total annual energy demand of residential buildings built based on zero energy criteria. Current zero energy building frameworks, tools and policies therefore may overlook more than ~80% of the total net energy balance annually.  The original contribution of this thesis is an integrated multi-scale zero energy building framework which has the capacity to gauge the relative effectiveness towards the deployment of zero energy residential buildings and neighbourhoods. This framework takes into account energy requirements and CO₂ emissions at the building scale, i.e. the embodied energy and operation energy demands, and at the city scale, i.e. the embodied energy of related transport modes including infrastructure and the transport operational energy demand of its users. This framework is implemented through the development of a quantification methodology which allows the analysis and evaluation of energy demand and CO₂ emissions pertaining to the deployment of zero energy residential buildings and districts. A case study, located in Auckland, New Zealand is used to verify, validate and investigate the potential of the developed framework.  Results confirm that each of the building (embodied and operational) and transport (embodied and operational) energy requirements represent a very significant share of the annual overall energy demand and associated CO₂ emissions of zero energy buildings. Consequently, rather than the respect of achieving a net zero energy building balance at the building scale, the research has revealed that it is more important, above all, to minimise building user-related and transportation energy demand at the city scale and maximise renewable energy production coupled with efficiency improvements at grid level. The application of the developed evaluation framework will enable building designers, urban planners, researchers and policy makers to deliver effective multi-scale zero energy building strategies which will ultimately contribute to reducing the overall environmental impact of the built environment today.</p>


2021 ◽  
Author(s):  
Toktam Saeid

In October 2009, Team North competed in the US DOE 2009 Solar Decathlon competition. Team North's mission was to design and deliver North House, an energy efficient solar-powered home while training Canada's next generation of leaders in sustainable design. In North House, the PV system on the roof was the primary energy generation, complimented by a custom PV cladding system on the south, east and west facades. A solar assisted heat pump system, including a three-tank heat transfer and storage system, the horizontally mounted evacuated-tube solar thermal collectors on the roof and a variable capacity heat pump met the hot water and space heating demands. A second variable capacity heat pump was utilized for space cooling. The solar thermal system was studied using TRNSYS simulation. For the initial assessments the simulations were run for Baltimore. Then, the analyses were extended to different cities across Canada. In all scenarios the same house was linked to the system. The minimum annual solar fraction of the different cities was 64% and it rose up to 81%. Finally, the data measured during the competition were analyzed and compared with the data resulting from the simulation. According to competition measures, during the 10 days of competition in Washington DC, the PV system generated 271.6kWh of electricity and the solar thermal system produced 91.7kWh while the house consumption was 294.1kWh. As a result, North House was evidently a net-positive house.


Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 6026
Author(s):  
Sergio Gómez Melgar ◽  
Antonio Sánchez Cordero ◽  
Marta Videras Rodríguez ◽  
José Manuel Andújar Márquez

The construction sector is a great contributor to global warming both in new and existing buildings. Minimum energy buildings (MEBs) demand as little energy as possible, with an optimized architectural design, which includes passive solutions. In addition, these buildings consume as low energy as possible introducing efficient facilities. Finally, they produce renewable energy on-site to become zero energy buildings (ZEBs) or even plus zero energy buildings (+ZEB). In this paper, a deep analysis of the energy use and renewable energy production of a social dwelling was carried out based on data measurements. Unfortunately, in residential buildings, most renewable energy production occurs at a different time than energy demand. Furthermore, energy storage batteries for these facilities are expensive and require significant maintenance. The present research proposes a strategy, which involves rescheduling energy demand by changing the habits of the occupants in terms of domestic hot water (DHW) consumption, cooking, and washing. Rescheduling these three electric circuits increases the usability of the renewable energy produced on-site, reducing the misused energy from 52.84% to 25.14%, as well as decreasing electricity costs by 58.46%.


Author(s):  
Michele Totaro ◽  
Anna Laura Costa ◽  
Lorenzo Frendo ◽  
Sara Profeti ◽  
Beatrice Casini ◽  
...  

Despite an increase of literature data on Legionella spp. presence in private water systems, epidemiological reports assert a continuing high incidence of Legionnaires’ disease infection in Italy. In this study, we report a survey on Legionella spp. colonization in 58 buildings with solar thermal systems for hot water production (TB). In all buildings, Legionella spp. presence was enumerated in hot and cold water samples. Microbiological potability standards of cold water were also evaluated. Legionella spp. was detected in 40% of the buildings. Moreover, we detected correlations between the count of Legionella spp. and the presence of the optimal temperature for the microorganism growth (less than 40 °C). Our results showed that cold water was free from microbiological hazards, but Legionella spp., was detected when the mean cold water temperature was 19.1 ± 2.2 °C. This may considered close to the suboptimal value for the Legionella growth (more then 20 °C). In conclusion, we observed the presence of a Legionnaires’ disease risk and the need of some strategies aimed to reduce it, such as the application of training programs for all the workers involved in water systems maintenance.


Author(s):  
Ali A. Jal-Alzadeh-Azar ◽  
Ren Anderson ◽  
Keith Gawlik

This paper demonstrates the potential impact of indoor air distribution on the energy consumption of central HVAC systems with cognizance of human thermal comfort. The study focuses on a hypothetical high-performance house incorporating a split heat pump system. The air distribution of this building incorporates high sidewall supply-air registers and near-floor, wall-mounted return-air grilles. Heating-mode stratification resulting from this prevalent configuration is a prime example of situations in which challenges regarding energy efficiency, comfort, and ventilation effectiveness emerge. These challenges underline the importance of adopting a comprehensive design strategy for high-performance buildings. Two indoor air distribution scenarios were analyzed: (1) theoretically well mixed and (2) poorly mixed, representing a realistic case. The former scenario was evaluated using an analytical approach, whereas the latter was investigated through computational fluid dynamics (CFD) simulations. For heating mode, the results indicated the presence of a pronounced thermal stratification resulting from poor air mixing. At 50% of the design heating load, for the well-mixed case, the HVAC system energy consumption was significantly higher. Considerably better air distribution performance was observed with cooling mode, in which the relative energy penalty for the well-mixed scenario was noticeably less. In real-world applications where measures must be taken to achieve near perfectly mixed indoor conditions for better comfort, the energy use is expected to be even higher. However, in the absence of such measures, the thermostat setpoint is likely to be readjusted, leading to a higher energy use without necessarily improving the overall comfort level, as demonstrated in this paper. The limitation of increasing the supply-air flow rate to enhance air mixing and diffusion is also discussed in terms of the system moisture removal capability.


Author(s):  
Jenny Chu ◽  
Cynthia A. Cruickshank ◽  
Wilkie Choi ◽  
Stephen J. Harrison

Heat pumps are commonly used for residential space-heating and cooling. The combination of solar thermal and heat pump systems as a single solar-assisted heat pump (SAHP) system can significantly reduce residential energy consumption in Canada. As a part of Team Ontario’s efforts to develop a high performance house for the 2013 DOE Solar Decathlon Competition, an integrated mechanical system (IMS) consisting of a SAHP was investigated. The system is designed to provide domestic hot water, space-heating, space-cooling and dehumidification. The system included a cold and a hot thermal storage tank and a heat pump to move energy from the low temperature reservoir, to the hot. The solar thermal collectors supplies heat to the cold storage and operate at a higher efficiency due to the heat pump reducing the temperature of the collector working fluid. The combination of the heat pump and solar thermal collectors allows more heat to be harvested at a lower temperature, and then boosted to a suitable temperature for domestic use via the heat pump. The IMS and the building’s energy loads were modeled using the TRNSYS simulation software. A parametric study was conducted to optimize the control, sizing and configuration of the system. This paper provides an overview of the model and summarizes the results of the study. The simulation results suggested that the investigated system can achieve a free energy ratio of about 0.583 for a high performance house designed for the Ottawa climate.


2016 ◽  
Vol 824 ◽  
pp. 347-354 ◽  
Author(s):  
Rastislav Ingeli ◽  
Miroslav Čekon

The trend in the components of residential buildings is low energy demand buildings in relation to the minimum costs spent by users for their operation. The main aim of their construction is to improve the energy economy of buildings, to reduce the environmental load in energy consumption, to improve the quality of the interior, to ensure the minimum cost level in the operation of buildings and their maintenance in the life cycle. The consequence of increased energy prices and the possible implementation of tax policies in the countries of Europe is more frequently designing and implementing energy self-contained buildings. This means that energy necessary for the general use of a building can be produced in it to certain extent. The concept of such buildings is not only in high quality heat insulating properties, but also in suitable installed devices utilizing alternative sources. The objective indicator of saving and proof of the required level of a building is an analysis of its real energy consumption. The paper analyzes the energy consumption in a specific house which, in the design phase, met the criteria for designing a nearly zero energy building. The analyzed building has a high thermal protection and uses photovoltaic energy as an alternative source. The main aim is to evaluate the concept of the designed nearly zero energy building and to assess it in relation to the really consumed energy.


Sign in / Sign up

Export Citation Format

Share Document