Role of Indoor Air Distribution in Performance of Heat Pump Systems in Energy-Efficient Residential Buildings

Author(s):  
Ali A. Jal-Alzadeh-Azar ◽  
Ren Anderson ◽  
Keith Gawlik

This paper demonstrates the potential impact of indoor air distribution on the energy consumption of central HVAC systems with cognizance of human thermal comfort. The study focuses on a hypothetical high-performance house incorporating a split heat pump system. The air distribution of this building incorporates high sidewall supply-air registers and near-floor, wall-mounted return-air grilles. Heating-mode stratification resulting from this prevalent configuration is a prime example of situations in which challenges regarding energy efficiency, comfort, and ventilation effectiveness emerge. These challenges underline the importance of adopting a comprehensive design strategy for high-performance buildings. Two indoor air distribution scenarios were analyzed: (1) theoretically well mixed and (2) poorly mixed, representing a realistic case. The former scenario was evaluated using an analytical approach, whereas the latter was investigated through computational fluid dynamics (CFD) simulations. For heating mode, the results indicated the presence of a pronounced thermal stratification resulting from poor air mixing. At 50% of the design heating load, for the well-mixed case, the HVAC system energy consumption was significantly higher. Considerably better air distribution performance was observed with cooling mode, in which the relative energy penalty for the well-mixed scenario was noticeably less. In real-world applications where measures must be taken to achieve near perfectly mixed indoor conditions for better comfort, the energy use is expected to be even higher. However, in the absence of such measures, the thermostat setpoint is likely to be readjusted, leading to a higher energy use without necessarily improving the overall comfort level, as demonstrated in this paper. The limitation of increasing the supply-air flow rate to enhance air mixing and diffusion is also discussed in terms of the system moisture removal capability.

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3876
Author(s):  
Sameh Monna ◽  
Adel Juaidi ◽  
Ramez Abdallah ◽  
Aiman Albatayneh ◽  
Patrick Dutournie ◽  
...  

Since buildings are one of the major contributors to global warming, efforts should be intensified to make them more energy-efficient, particularly existing buildings. This research intends to analyze the energy savings from a suggested retrofitting program using energy simulation for typical existing residential buildings. For the assessment of the energy retrofitting program using computer simulation, the most commonly utilized residential building types were selected. The energy consumption of those selected residential buildings was assessed, and a baseline for evaluating energy retrofitting was established. Three levels of retrofitting programs were implemented. These levels were ordered by cost, with the first level being the least costly and the third level is the most expensive. The simulation models were created for two different types of buildings in three different climatic zones in Palestine. The findings suggest that water heating, space heating, space cooling, and electric lighting are the highest energy consumers in ordinary houses. Level one measures resulted in a 19–24 percent decrease in energy consumption due to reduced heating and cooling loads. The use of a combination of levels one and two resulted in a decrease of energy consumption for heating, cooling, and lighting by 50–57%. The use of the three levels resulted in a decrease of 71–80% in total energy usage for heating, cooling, lighting, water heating, and air conditioning.


Energies ◽  
2019 ◽  
Vol 12 (21) ◽  
pp. 4046 ◽  
Author(s):  
Sooyoun Cho ◽  
Jeehang Lee ◽  
Jumi Baek ◽  
Gi-Seok Kim ◽  
Seung-Bok Leigh

Although the latest energy-efficient buildings use a large number of sensors and measuring instruments to predict consumption more accurately, it is generally not possible to identify which data are the most valuable or key for analysis among the tens of thousands of data points. This study selected the electric energy as a subset of total building energy consumption because it accounts for more than 65% of the total building energy consumption, and identified the variables that contribute to electric energy use. However, this study aimed to confirm data from a building using clustering in machine learning, instead of a calculation method from engineering simulation, to examine the variables that were identified and determine whether these variables had a strong correlation with energy consumption. Three different methods confirmed that the major variables related to electric energy consumption were significant. This research has significance because it was able to identify the factors in electric energy, accounting for more than half of the total building energy consumption, that had a major effect on energy consumption and revealed that these key variables alone, not the default values of many different items in simulation analysis, can ensure the reliable prediction of energy consumption.


Author(s):  
Jerzy Sowa ◽  
Maciej Mijakowski

A humidity-sensitive demand-controlled ventilation system is known for many years. It has been developed and commonly applied in regions with an oceanic climate. Some attempts were made to introduce this solution in Poland in a much severe continental climate. The article evaluates this system's performance and energy consumption applied in an 8-floor multi-unit residential building, virtual reference building described by the National Energy Conservation Agency NAPE, Poland. The simulations using the computer program CONTAM were performed for the whole hating season for Warsaw's climate. Besides passive stack ventilation that worked as a reference, two versions of humidity-sensitive demand-controlled ventilation were checked. The difference between them lies in applying the additional roof fans that convert the system to hybrid. The study confirmed that the application of demand-controlled ventilation in multi-unit residential buildings in a continental climate with warm summer (Dfb) leads to significant energy savings. However, the efforts to ensure acceptable indoor air quality require hybrid ventilation, which reduces the energy benefits. It is especially visible when primary energy use is analyzed.


Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1049 ◽  
Author(s):  
Sangtae No ◽  
Chungyeon Won

Although interest in and the importance of green building certification have increased, it is difficult to determine how much less energy the buildings actually consume after obtaining sustainability related certification, such as LEED in the USA, and G-SEED in Korea. Focusing on building energy evaluation, we compared and analyzed the energy evaluation items of LEED and G-SEED. In addition, from the Korean public data portal site, this study investigated the annual site energy consumption (electricity and gas) per floor area of non-residential buildings that obtained G-SEED certification in Korea. The energy consumption of non-certified general buildings was compared with the energy consumption of certified buildings. As a result of examining 84 samples of this study, non-residential buildings with G-SEED certification showed energy use intensity that was at least (35.5 to 48.9)% lower than that of uncertified buildings.


Information ◽  
2019 ◽  
Vol 10 (3) ◽  
pp. 108 ◽  
Author(s):  
Abdul Shah ◽  
Haidawati Nasir ◽  
Muhammad Fayaz ◽  
Adidah Lajis ◽  
Asadullah Shah

In recent years, due to the unnecessary wastage of electrical energy in residential buildings, the requirement of energy optimization and user comfort has gained vital importance. In the literature, various techniques have been proposed addressing the energy optimization problem. The goal of each technique is to maintain a balance between user comfort and energy requirements, such that the user can achieve the desired comfort level with the minimum amount of energy consumption. Researchers have addressed the issue with the help of different optimization algorithms and variations in the parameters to reduce energy consumption. To the best of our knowledge, this problem is not solved yet due to its challenging nature. The gaps in the literature are due to advancements in technology, the drawbacks of optimization algorithms, and the introduction of new optimization algorithms. Further, many newly proposed optimization algorithms have produced better accuracy on the benchmark instances but have not been applied yet for the optimization of energy consumption in smart homes. In this paper, we have carried out a detailed literature review of the techniques used for the optimization of energy consumption and scheduling in smart homes. Detailed discussion has been carried out on different factors contributing towards thermal comfort, visual comfort, and air quality comfort. We have also reviewed the fog and edge computing techniques used in smart homes.


Energies ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 3348 ◽  
Author(s):  
Jaesung Park ◽  
Taeyeon Kim ◽  
Chul-sung Lee

In Kuwait, where the government subsidizes approximately 95% of residential electricity bills, most of the country’s energy consumption is for residential use. In particular, air-conditioning (AC) systems for cooling, which are used throughout the year, are responsible for residential electric energy consumption. This study aimed to reduce the amount of energy consumed for cooling purposes by developing a thermal comfort-based controller. Our study commenced by using a simulation model to investigate the possibility of energy reduction when using the predicted mean vote (PMV) for optimal control. The result showed that control optimization would enable the cooling energy consumption to be reduced by 33.5%. The influence of six variables on cooling energy consumption was then analyzed to develop a thermal comfort-based controller. The analysis results showed that the indoor air temperature was the most influential factor, followed by the mean radiant temperature, the metabolic rate, and indoor air velocity. The thermal comfort-based controller-version 1 (TCC-V1) was developed based on the analysis results and experimentally evaluated to determine the extent to which the use of the controller would affect the energy consumed for cooling. The experiments showed that the implementation of TCC-V1 control made it possible to reduce the electric energy consumption by 39.5% on a summer representative day. The results of this study indicate that it is possible to improve indoor thermal comfort while saving energy by using the thermal comfort-based controller in residential buildings in Kuwait.


2020 ◽  
pp. 174425912094460
Author(s):  
Yan Zhou ◽  
Jianmin Cai ◽  
Yiwen Xu

In order to get more comprehensive operation performance on indoor environment quality (IEQ) and energy consumption, a long-time measurement and a field occupants’ satisfaction survey on IEQ performance of the first three-star-operation-certified green office building in Ningbo city of China have been conducted, and environmental energy efficiency (EEE) also has been analyzed. Moreover, IEQ and energy consumption of the green case office building are compared with other green office example buildings of the same climate zone in other literatures. The results show that the actual indoor thermal environment of the green case office building isn’t quite achieving the design goals with the Chinese standard of thermal comfort level II (GB 50736). Although indoor air quality of CO2 concentration and visual environment are consistent with the design goals, the indoor relative humidity doesn’t reach the design goal in most of the year. The questionnaire survey results illustrate that the green case building has a high occupants’ satisfaction on IEQ. The comparison results show that there is no obvious difference in indoor temperature and visual environment between the green case building and the green office example buildings in other studies. The results of occupant’s satisfaction and CO2 concentration of the green case building are better than in other studies. However, the indoor relative humidity of the green case building in every season is much higher than in other researches. Energy use intensity (EUI) of the green case building is about 56.5 kWh/m2·a, which is much lower than the constraint value of the Chinese standard. The actual performance of the green case building is also evaluated by the indicator of EEE. The results of this article can provide useful reference for green building operational performance promotion and feedback for design phase optimization.


2020 ◽  
Vol 12 (20) ◽  
pp. 8515 ◽  
Author(s):  
Jonghoon Ahn

For the sustainable use of building spaces, various methods have been studied to satisfy specific conditions required by the characteristics of space types and the energy use in operation. However, several effective control approaches adopting the latest statistical tools may have problems such as higher control precision increases energy consumption, or lower energy consumption decreases their control precision. This study proposes an optimized model to reach the indoor set-point temperature by controlling the amount of heating supply air and its temperature and investigates the efficiency of an adaptive controller to maintain indoor thermal comfort within setting ranges. In the consistency of the comfort level, the fuzzy logic controller was found to be 1.76% and the artificial neural network controller to be 17.83%, respectively, more efficient than the conventional thermostat. In addition, for energy use efficiency, both of the controllers were confirmed to be over 3.0% more efficient. Consequently, the network-based controller with the adaptive controller checking comfort levels effectively works to improve both energy efficiency and thermal comfort. This improvement can be significant in places such as commercial high-rises, large hospitals, and data centers where many spaces are intensively woven with appropriate thermal environments to maintain users’ workability.


2020 ◽  
Vol 12 (1) ◽  
pp. 351 ◽  
Author(s):  
Hossein Omrany ◽  
Veronica Soebarto ◽  
Ehsan Sharifi ◽  
Ali Soltani

Residential buildings are responsible for a considerable portion of energy consumption and greenhouse gas emissions worldwide. Correspondingly, many attempts have been made across the world to minimize energy consumption in this sector via regulations and building codes. The focus of these regulations has mainly been on reducing operational energy use, whereas the impacts of buildings’ embodied energy are frequently excluded. In recent years, there has been a growing interest in analyzing the energy performance of buildings via a life cycle energy assessment (LCEA) approach. The increasing amount of research has however caused the issue of a variation in results presented by LCEA studies, in which apparently similar case studies exhibited different results. This paper aims to identify the main sources of variation in LCEA studies by critically analyzing 26 studies representing 86 cases in 12 countries. The findings indicate that the current trend of LCEA application in residential buildings suffers from significant inaccuracy accruing from incomplete definitions of the system boundary, in tandem with the lack of consensus on measurements of operational and embodied energies. The findings call for a comprehensive framework through which system boundary definition for calculations of embodied and operational energies can be standardized.