Film cooling injection hole geometry - Hole shape comparison for compound cooling orientation

AIAA Journal ◽  
2001 ◽  
Vol 39 ◽  
pp. 1493-1499
Author(s):  
Ian Gartshore ◽  
Martha Salcudean ◽  
Ibrahim Hassan
AIAA Journal ◽  
2001 ◽  
Vol 39 (8) ◽  
pp. 1493-1499 ◽  
Author(s):  
Ian Gartshore ◽  
Martha Salcudean ◽  
Ibrahim Hassan

1999 ◽  
Vol 122 (3) ◽  
pp. 553-557 ◽  
Author(s):  
C. A. Hale ◽  
M. W. Plesniak ◽  
S. Ramadhyani

The adiabatic, steady-state liquid crystal technique was used to measure surface adiabatic film cooling effectiveness values in the near-hole region X/D<10. A parametric study was conducted for a single row of short holes L/D⩽3 fed by a narrow plenum H/D=1. Film cooling effectiveness values are presented and compared for various L/D ratios (0.66 to 3.0), three different blowing ratios (0.5, 1.0, and 1.5), two different plenum feed configurations (co-flow and counterflow), and two different injection angles (35 and 90 deg). Injection hole geometry and plenum feed direction were found to affect short hole film cooling performance significantly. Under certain conditions, similar or improved coverage was achieved with 90 deg holes compared with 35 deg holes. This result has important implications for manufacturing of thin-walled film-cooled blades or vanes. [S0889-504X(00)00603-6]


Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Charles P. Brown ◽  
Weston V. Harmon

A novel, double hole film cooling configuration is investigated as an alternative to traditional cylindrical and fanshaped, laidback holes. This experimental investigation utilizes a Stereo-Particle Image Velocimetry (S-PIV) to quantitatively assess the ability of the proposed, double hole geometry to weaken or mitigate the counter-rotating vortices formed within the jet structure. The three-dimensional flow field measurements are combined with surface film cooling effectiveness measurements obtained using Pressure Sensitive Paint (PSP). The double hole geometry consists of two compound angle holes. The inclination of each hole is θ = 35°, and the compound angle of the holes is β = ± 45° (with the holes angled toward one another). The simple angle cylindrical and shaped holes both have an inclination angle of θ = 35°. The blowing ratio is varied from M = 0.5 to 1.5 for all three film cooling geometries while the density ratio is maintained at DR = 1.0. Time averaged velocity distributions are obtained for both the mainstream and coolant flows at five streamwise planes across the fluid domain (x/d = −4, 0, 1, 5, and 10). These transverse velocity distributions are combined with the detailed film cooling effectiveness distributions on the surface to evaluate the proposed double hole configuration (compared to the traditional hole designs). The fanshaped, laidback geometry effectively reduces the strength of the kidney-shaped vortices within the structure of the jet (over the entire range of blowing ratios considered). The three-dimensional velocity field measurements indicate the secondary flows formed from the double hole geometry strengthen in the plane perpendicular to the mainstream flow. At the exit of the double hole geometry, the streamwise momentum of the jets is reduced (compared to the single, cylindrical hole), and the geometry offers improved film cooling coverage. However, moving downstream in the steamwise direction, the two jets form a single jet, and the counter-rotating vortices are comparable to those formed within the jet from a single, cylindrical hole. These strong secondary flows lift the coolant off the surface, and the film cooling coverage offered by the double hole geometry is reduced.


Author(s):  
Atui Kohil ◽  
David G. Bogard

In this study the film cooling performance of a single row of discrete holes inclined at an injection angle of 55° is investigated at a density ratio of DR = 1.6. Three different hole geometries were used in this study, a round hole and two shaped holes. One shaped hole had forward and lateral expansions of 15°, and the other a 15° lateral with a 25° forward expansion. For reference, a round hole with an injection angle of 35° was also tested. The film cooling performance of each hole shape was evaluated using adiabatic effectiveness, thermal field, and velocity field measurements. The shaped holes showed higher spatially averaged adiabatic effectiveness than the round hole over the whole range of momentum flux ratios (I) investigated. The effectiveness values for the shaped holes were only marginally better than the round hole at the low I, but at the high I, the shaped holes performed much better than the round hole. The temperature and velocity field measurements near the hole exit suggest that there is a slight detachment of the jet from the wall for the round hole, while the jets remain attached for the two shaped holes. The shaped hole with the larger forward expansion had a warmer jet with a higher trajectory at the hole exit suggesting ingestion of mainstream fluid and flow separation within the hole.


1990 ◽  
Vol 112 (3) ◽  
pp. 428-436 ◽  
Author(s):  
P. M. Ligrani ◽  
W. Williams

Effects of embedded longitudinal vortices on heat transfer in turbulent boundary layers with injection from a single film-cooling hole are described. These results were obtained at a free-stream velocity of 10 m/s, with a film-cooling hole inclined 30 deg to the horizontal and a blowing ratio of about 0.50. The ratio of vortex core diameter to injection hole diameter was 1.58, and the ratio of circulation to injection velocity time hole diameter was about 3.16. Coolant distributions and spatially resolved heat transfer measurements indicate that injection hole centerlines must be at least 2.9–3.4 vortex core diameters away from the vortex center in the lateral direction to avoid significant alterations to wall heat transfer and distributions of film coolant. Under these circumstances, protection from film cooling is evident at least up to 55 hole diameters downstream of injection. When the injection hole is closer to the vortex center, secondary flows convect most injectant into the vortex upwash and thermal protection from film cooling is destroyed for streamwise locations from the injection hole greater than 17.5 hole diameters.


2021 ◽  
Author(s):  
Siavash Khajehhasani

A numerical investigation of the film cooling performance on novel film hole schemes is presented using Reynolds-Averaged Navier-Stokes analysis. The investigation considers low and high blowing ratios for both flat plate film cooling and the leading edge of a turbine blade. A novel film hole geometry using a circular exit shaped hole is proposed, and the influence of an existing sister holes’ technique is investigated. The results indicate that high film cooling effectiveness is achieved at higher blowing ratios, results of which are even greater when in the presence of discrete sister holes where film cooling effectiveness results reach a plateau. Furthermore, a decrease in the strength of the counter-rotating vortex pairs is evident, which results in more attached coolant to the plate’s surface and a reduction in aerodynamic losses. Modifications are made to the spanwise and streamwise locations of the sister holes around the conventional cylindrical hole geometry. It is found that the spanwise variations have a significant influence on the film cooling effectiveness results, while only minor effects are observed for the streamwise variations. Positioning the sister holes in locations farther from the centerline increases the lateral spreading of the coolant air over the plate’s surface. This result is further verified through the flow structure analysis. Combinations of sister holes are joined with the primary injection hole to produce innovative variant sister shaped single-holes. The jet lift-off is significantly decreased for the downstream and up/downstream configurations of the proposed scheme for the flat plate film cooling. These schemes have shown notable film cooling improvements whereby more lateral distribution of coolant is obtained and less penetration of coolant into the mainstream flow is observed. The performance of the sister shaped single-holes are evaluated at the leading edge of a turbine blade. At the higher blowing ratios, a noticeable improvement in film cooling performance including the effectiveness and the lateral spread of the cooling air jet has been observed for the upstream and up/downstream schemes, in particular on the suction side. It is determined that the mixing of the coolant with the high mainstream flow at the leading edge of the blade is considerably decreased for the upstream and up/downstream configurations and more adhered coolant to the blade’s surface is achieved.


2020 ◽  
Vol 165 ◽  
pp. 114578 ◽  
Author(s):  
Nan Cao ◽  
Xue Li ◽  
Zeyu Wu ◽  
Xiang Luo

Author(s):  
Alexandros Terzis ◽  
Charilaos Kazakos ◽  
Nikolaos Papadopoulos ◽  
Anestis I. Kalfas ◽  
Pavlos K. Zachos ◽  
...  

The penetration of a jet of fluid into a traversal moving stream is a basic configuration of a wide range of engineering applications, such as film cooling and V/STOL aircrafts. This investigation examines experimentally the effect of blowing ratio of fans in cross flow, and numerically, the effect of the swirl velocity of jets in cross flow, downstream of the injection hole. The experimental results indicated an agreement with typically straight jets in cross flow (no vorticity), illustrating that the trace of the jet, remains close to the wall and subsequently enhance cooling at low blowing ratios in the case of turbine blade applications. However, the rotation of the jet results in an imparity between the two parts of the counter rotating vortex pair (CVP), and as a consequence, the injected fluid not only bends in the direction of the main stream but also diverts in the direction of the rotation, in order to conserve its angular momentum. The induction of the swirl velocity on the injected jet destructs one of the two parts of the kidney vortex which entrains fluid from the cross flow to the jet promoting the mixing between the two fluids, while the trace of a swirled jet remains closer to the wall downstream of the injection hole. Finally, the use of contra rotating jet or fan configurations reduces the wall shear stress in a very great extent, leading to better thermal protection of turbine blades, as well as cancels out the yaw torques of each fan separately, resulting in better flight control of typical lift surface.


Sign in / Sign up