scholarly journals Effects of Hole Shape on Film Cooling With Large Angle Injection

Author(s):  
Atui Kohil ◽  
David G. Bogard

In this study the film cooling performance of a single row of discrete holes inclined at an injection angle of 55° is investigated at a density ratio of DR = 1.6. Three different hole geometries were used in this study, a round hole and two shaped holes. One shaped hole had forward and lateral expansions of 15°, and the other a 15° lateral with a 25° forward expansion. For reference, a round hole with an injection angle of 35° was also tested. The film cooling performance of each hole shape was evaluated using adiabatic effectiveness, thermal field, and velocity field measurements. The shaped holes showed higher spatially averaged adiabatic effectiveness than the round hole over the whole range of momentum flux ratios (I) investigated. The effectiveness values for the shaped holes were only marginally better than the round hole at the low I, but at the high I, the shaped holes performed much better than the round hole. The temperature and velocity field measurements near the hole exit suggest that there is a slight detachment of the jet from the wall for the round hole, while the jets remain attached for the two shaped holes. The shaped hole with the larger forward expansion had a warmer jet with a higher trajectory at the hole exit suggesting ingestion of mainstream fluid and flow separation within the hole.

2021 ◽  
Author(s):  
Jacob D. Moore ◽  
Christopher C. Easterby ◽  
David G. Bogard

Abstract The high heat loads at the leading-edge regions of turbine vanes and blades necessitate the most robust thermal protection, typically accomplished via a dense array of film cooling holes, nicknamed the “showerhead.” Although research has shown that film cooling using shaped holes provides more reliable thermal protection than that using cylindrical holes, the effects on cooling performance from varying the geometric details of the shaped hole design are not well characterized. In this study, adiabatic effectiveness and off-the-wall thermal field measurements were conducted for two shaped hole geometries designed as successors to a baseline hole geometry presented in a previous study. One geometry with a 40% increase in area ratio exhibited only a marginal improvement in adiabatic effectiveness (∼10%). A second design with a 12° forward and lateral expansion angle with a breakout area 40% larger performed marginally worse than its matched area ratio counterpart (∼15% lower), suggesting a negative sensitivity to breakout area. Such changes in performance for different shaped hole designs were small compared to the boost in performance gained by switching from a cylindrical hole to a shaped hole, which suggests cooling performance is insensitive to specific shaped hole details provided the exterior coolant flow is well-attached.


2021 ◽  
Author(s):  
Jacob D. Moore ◽  
Christopher C. Easterby ◽  
David G. Bogard

Abstract The effects that leading-edge impingement coolant feeds have on the external flowfield and on film cooling performance in the showerhead have not been studied thoroughly in the literature. To isolate the influence of the impingement feed, experimental adiabatic effectiveness and off-the-wall thermal field measurements were made using a shaped hole geometry fed by an ideal plenum coolant feed and by an engine-realistic impingement coolant feed. The impingement configuration exhibited around 10% higher adiabatic effectiveness levels than the plenum configuration did — a finding in agreement with the few studies isolating this effect. CFD RANS simulations of the impingement and the pseudo-plenum configurations from a companion study were consulted to investigate the root cause of this difference in performance because the experimental data alone did not sufficiently explain it. In the impingement feed simulation, flow remained better attached throughout the hole (both at the inlet and at the diffuser) due to a rotation caused by the impingement flow, leading to better attachment on the exterior surface. This was most significant for the suction side holes at higher blowing ratios wherein the pseudo-plenum caused much more severe separation in the holes than the impingement configuration did.


Author(s):  
Marcia I. Ethridge ◽  
J. Michael Cutbirth ◽  
David G. Bogard

An experimental study was conducted to investigate the film cooling performance on the suction side of a first stage turbine vane. Tests were conducted on a nine times scale vane model at density ratios of DR = 1.1 and 1.6 over a range of blowing conditions, 0.2 ≤ M ≤ 1.5 and 0.05 ≤ I ≤ 1.2. Two different mainstream turbulence intensity levels, Tu∞ = 0.5% and 20%, were also investigated. The row of coolant holes studied was located in a position of both strong curvature and strong favorable pressure gradient. In addition, its performance was isolated by blocking the leading edge showerhead coolant holes. Adiabatic effectiveness measurements were made using an infrared camera to map the surface temperature distribution. The results indicate that film cooling performance was greatly enhanced over holes with a similar 50° injection angle on a flat plate. Overall, adiabatic effectiveness scaled with mass flux ratio for low blowing conditions and with momentum flux ratio for high blowing conditions. However, for M < 0.5 there was a higher rate of decay for the low density ratio data. High mainstream turbulence had little effect at low blowing ratios, but degraded performance at higher blowing ratios.


Author(s):  
Antar M. M. Abdala ◽  
Qun Zheng ◽  
Fifi N. M. Elwekeel

In the present work, computational simulations was made using ANSYS CFX to predict the improvements in film cooling performance with multi trench. Multi-trench configuration consists of two trenches together, one wider trench and the other is narrow trench that extruded from the wider one. Several blowing ratios in the range (0.5:5) were investigated. By using the multi trench configuration, the coolant jet impacted the trench wall two times allowing increasing the spreading of coolant laterally in the trench, reducing jet velocity and jet completely covered on the surface. The results indicate that this configuration increased adiabatic effectiveness as blowing ratio increased. No observed film blow-off at all blowing ratios. The adiabatic film effectiveness of multi trench case outperformed the narrow trench case, laidback fan-shaped hole, fan-shaped hole and cylinder hole at different blowing ratios. An additional benefit is the low flow rate will provide the same cooling effect by using multi trench configuration.


Author(s):  
Ellen Wilkes ◽  
Joshua Anderson ◽  
John McClintic ◽  
David Bogard

This study focuses on specifics of gas turbine film cooling. Laboratory film cooling tests are important for industry because actual engine conditions are too hot, too small, and too fast to take accurate and high resolution measurements. Experiments are typically conducted using a plenum to feed coolant through round or shaped film cooling holes. Less common are experiments using cross-flow fed coolant, a method that flows coolant perpendicular to the mainstream flow and better represents engine designs. There are a few studies that have explored shaped holes in cross-flow, but none have looked at the effect cross-flow channel parameters other than Mach number. Here, the effectiveness of film cooling is quantified by measuring adiabatic effectiveness on a flat plate with a single row of shaped film cooling holes in cross-flow. A preliminary examination of the effect of cross-flow versus plenum fed coolant on the adiabatic effectiveness of the axial 7-7-7 shaped hole, a laidback fan-shaped hole with a 30 degree injection angle, is first conducted. Subsequently, the effects of two internal coolant parameters on film cooling effectiveness are presented: Reynold’s number inside the cross-flow channel, and velocity ratio (defined as the ratio of cross-flow channel average velocity to mainstream velocity). By measuring the effect of these parameters, a chain of relative importance can be generated and applied to future experimentation. Parameters that heavily influence film cooling effectiveness can be studied further and optimized for turbine film cooling design.


2000 ◽  
Vol 123 (2) ◽  
pp. 231-237 ◽  
Author(s):  
Marcia I. Ethridge ◽  
J. Michael Cutbirth ◽  
David G. Bogard

An experimental study was conducted to investigate the film cooling performance on the suction side of a first-stage turbine vane. Tests were conducted on a nine times scale vane model at density ratios of DR=1.1 and 1.6 over a range of blowing conditions, 0.2⩽M⩽1.5 and 0.05⩽I⩽1.2. Two different mainstream turbulence intensity levels, Tu∞=0.5 and 20 percent, were also investigated. The row of coolant holes studied was located in a position of both strong curvature and strong favorable pressure gradient. In addition, its performance was isolated by blocking the leading edge showerhead coolant holes. Adiabatic effectiveness measurements were made using an infrared camera to map the surface temperature distribution. The results indicate that film cooling performance was greatly enhanced over holes with a similar 50 deg injection angle on a flat plate. Overall, adiabatic effectiveness scaled with mass flux ratio for low blowing conditions and with momentum flux ratio for high blowing conditions. However, for M<0.5, there was a higher rate of decay for the low density ratio data. High mainstream turbulence had little effect at low blowing ratios, but degraded performance at higher blowing ratios.


Author(s):  
Vinod U. Kakade ◽  
Steven J. Thorpe ◽  
Miklós Gerendás

The thermal management of aero gas turbine engine combustion systems commonly employs effusion-cooling in combination with various cold-side convective cooling schemes. The combustor liner incorporates many small holes which are usually set in staggered arrays and at a shallow angle to the cooled surface; relatively cold compressor delivery air is then allowed to flow through these holes to provide the full-coverage film-cooling effect. The efficient design of such systems requires robust correlations of film-cooling effectiveness and heat transfer coefficient at a range of aero-thermal conditions, and the use of appropriately validated computational models. However, the flow conditions within a combustor are characterised by particularly high turbulence levels and relatively large length scales. The experimental evidence for performance of effusion-cooling under such flow conditions is currently sparse. The work reported here is aimed at quantifying typical effusion-cooling performance at a range of combustor relevant free-stream conditions (high turbulence), and also to assess the importance of modeling the coolant to free-stream density ratio. Details of a new laboratory wind-tunnel facility for the investigation of film-cooling at high turbulence levels are reported. For a typical combustor effusion geometry that uses cylindrical holes, spatially resolved measurements of adiabatic effectiveness, heat transfer coefficient and net heat flux reduction are presented for a range of blowing ratios (0.48 to 2), free-stream turbulence conditions (4 and 22%) and density ratios (0.97 and 1.47). The measurements reveal that elevated free-stream turbulence impacts on both the adiabatic effectiveness and heat transfer coefficient, although this is dependent upon the blowing ratio being employed and particularly the extent to which the coolant jets detach from the surface. At low blowing ratios the presence of high turbulence levels causes increased lateral spreading of the coolant adjacent to the injection points, but more rapid degradation in the downstream direction. At high blowing ratios, high turbulence levels cause a modest increase in effectiveness due to turbulent transport of the detached coolant fluid. Additionally, the augmentation of heat transfer coefficient caused by the coolant injection is seen to be increased at high free-stream turbulence levels.


Author(s):  
Siavash Khajehhasani ◽  
Bassam Jubran

A numerical investigation of the film cooling performance from novel sister shaped single-holes (SSSH) is presented in this paper and the obtained results are compared with a single cylindrical hole, a forward diffused shaped hole, as well as discrete sister holes. Three types of the novel sister shaped single-hole schemes namely downstream, upstream and up/downstream SSSH, are designed based on merging the discrete sister holes to the primary hole in order to reduce the jet lift-off effect and increase the lateral spreading of the coolant on the blade surface as well as a reduction in the amount of coolant in comparison with discrete sister holes. The simulations are performed using three-dimensional Reynolds-Averaged Navier Stokes analysis with the realizable k–ε model combined with the standard wall function. The upstream SSSH demonstrates similar film cooling performance to that of the forward diffused shaped hole for the low blowing ratio of 0.5. While it performs more efficiently at M = 1, where the centerline and laterally averaged effectiveness results improved by 70% and 17%, respectively. On the other hand, the downstream and up/downstream SSSH schemes show a considerable improvement in film cooling performance in terms of obtaining higher film cooling effectiveness and less jet lift-off effect as compared with the single cylindrical and forward diffused shaped holes for both blowing ratios of M = 0.5 and 1. For example, the laterally averaged effectiveness for the downstream SSSH configuration shows an improvement of approximately 57% and 110% on average as compared to the forward diffused shaped hole for blowing ratios of 0.5 and 1, respectively.


Author(s):  
Rui Zhu ◽  
Gongnan Xie ◽  
Terrence W. Simon

Secondary holes to a main film cooling hole are used to improve film cooling performance by creating anti-kidney vortices. The effects of injection angle of the secondary holes on both film cooling effectiveness and surrounding thermal and flow fields are investigated in this numerical study. Two kinds of primary hole shapes are adopted. One is a cylindrical hole, the other is a horn-shaped hole which is designed from a cylindrical hole by expanding the hole in the transverse direction to double the hole size at the exit. Two smaller cylindrical holes, the secondary holes, are located symmetrically about the centerline and downstream of the primary hole. Three compound injection angles (α = 30°, 45° and 60°, β = 30°) of the secondary holes are analyzed while the injection angle of the primary hole is kept at 45°. Cases with various blowing ratios are computed. It is shown from the simulation that cooling effectiveness of secondary holes with a horn-shaped primary hole is better than that with a cylindrical primary hole, especially at high blowing ratios. With a cylindrical primary hole, increasing inclination angle of the secondary holes provides better cooling effectiveness because the anti-kidney vortices created by shallow secondary holes cannot counteract the kidney vortex pairs adequately, enhancing mixing of main flow and coolant. For secondary holes with a horn-shaped primary hole, large secondary hole inclination angles provide better cooling performance at low blowing ratios; but, at high blowing ratios, secondary holes with small inclination angles are more effective, as the film coverage becomes wider in the downstream area.


Sign in / Sign up

Export Citation Format

Share Document