Experimental Study of Tip Leakage Flow in the Linear Compressor Cascade: Part II - Effect of Moving Wall

Author(s):  
Qing Tian ◽  
Roger Simpson
1993 ◽  
Author(s):  
S. Kang ◽  
C. Hirsch

Tip leakage flow in a linear compressor cascade of NACA 65-1810 profiles is investigated, for tip clearance levels of 1.0, 2.0 and 3.25 percent of chord at design and off-design flow conditions. Data, velocity and pressures, are collected from three transverse sections inside tip clearance and sixteen sections within flow passage. Tip separation vortex influence is identified from the data. Leakage flow mixing is clearly present inside the clearance and has a significant influence on the internal loss.


2013 ◽  
Vol 2013 (0) ◽  
pp. _J055031-1-_J055031-5
Author(s):  
Hideo TANIGUCHI ◽  
Ken-ichi FUNAZAKI ◽  
Masahiro KATO ◽  
Masafumi KUMAGAI ◽  
Ryutaro ISHIMURA ◽  
...  

1994 ◽  
Vol 116 (4) ◽  
pp. 657-664 ◽  
Author(s):  
S. Kang ◽  
C. Hirsch

Tip leakage flow in a linear compressor cascade of NACA 65-1810 profiles is investigated, for tip clearance levels of 1.0, 2.0, and 3.25 percent of chord at design and off-design flow conditions. Velocity and pressure data are collected from three transverse sections inside tip clearance and sixteen sections within flow passage. Tip separation vortex influence is identified from the data. Leakage flow mixing is clearly present inside the clearance and has a significant influence on the internal loss.


2011 ◽  
Vol 2011 (0) ◽  
pp. _J051052-1-_J051052-4
Author(s):  
Kazunari MATSUDA ◽  
Kenichi FUNAZAKI ◽  
Hideo TANIGUCHI ◽  
Hiromasa KATO ◽  
Masafumi KUMAGAI ◽  
...  

ACTA IMEKO ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 277
Author(s):  
Masanao Kaneko

In this study, the influences of the single groove installed at the mid-chord – which is known to have a large expansion effect on the stable operating flow range of low-speed axial compressors – on the flow behaviour and the loss generation in a linear compressor cascade were investigated numerically at different tip clearances. Reynolds-averaged Navier–Stokes simulations of the incompressible flow in the test cascade were performed, with the computed results clarifying the following remarkable phenomena, which are common to both small and large tip-clearance cases. The single groove locally weakens the tip leakage flow by the decrease in the blade loading and the streaming of the flow near the blade pressure side into the groove, consequently reducing the distance between the tip leakage vortex and the blade suction surface. Meanwhile, although the groove decreases the loss due to the tip leakage vortex generated from the blade leading edge, the loss generation in the entire cascade passage is almost the same as that in the cascade without the groove due to the additional loss generation resulting from the presence of the groove.


Author(s):  
Domenico Borello ◽  
Giovanni Delibra ◽  
Franco Rispoli

In this paper we present an innovative Partially Averaged Navier Stokes (PANS) approach for the simulation of turbomachinery flows. The elliptic relaxation k-ε-ζ-f model was used as baseline Unsteady Reynolds Averaged Navier Stokes (URANS) model for the derivation of the PANS formulation. The well established T-FlowS unstructured finite volume in-house code was used for the computations. A preliminary assessment of the developed formulation was carried out on a 2D hill flow that represents a very demanding test case for turbulence models. The turbomachinery flow here investigated reproduces the experimental campaign carried out at Virginia Tech on a linear compressor cascade with tip leakage. Their measurements were used for comparisons with numerical results. The predictive capabilities of the model were assessed through the analysis of the flow field. Then an investigation of the blade passage, where experiments were not available, was carried out to detect the main loss sources.


Sign in / Sign up

Export Citation Format

Share Document