Supersonic Boundary Layer Interactions with Various Micro-Vortex Generator Geometries

Author(s):  
Sang Lee ◽  
Eric Loth
Shock Waves ◽  
2014 ◽  
Vol 25 (5) ◽  
pp. 521-533 ◽  
Author(s):  
D. Estruch-Samper ◽  
L. Vanstone ◽  
R. Hillier ◽  
B. Ganapathisubramani

Author(s):  
Shan Ma ◽  
Wuli Chu ◽  
Haoguang Zhang ◽  
Chuanle Liu

The performance of a compressor cascade is considerably influenced by flow control methods. In this paper, the synergistic effects of combination between micro-vortex generators (MVG) and boundary layer suction (BLS) are discussed in a high-load compressor cascade. Seven cases, which are grouped by a kind of micro-vortex generator and boundary layer suction with three locations, are investigated to control secondary flow effects and enhance the aerodynamic performance of the compressor cascade. The MVG is mounted on the end-wall in front of the passage. The rectangle suction slot with three radial positions is installed on the blade suction surface near the trailing edge. The numerical results show that: at the design condition, the total pressure loss is effectively decreased as well as the static pressure coefficient increase when the combined MVG and SBL method (COM) is used, which is superior to MVG in an aerodynamic performance. At the stall condition, the induced vortex coming from MVG could mix the low-energy fluid and mainstream, which result in the reduced separation, and the total pressure loss decreased by 11.54% when the suction flow ratio is 1.5%. The total pressure loss decreases by 14.59% when the COM control methods are applied.


2009 ◽  
Vol 113 (1149) ◽  
pp. 683-697 ◽  
Author(s):  
S. Lee ◽  
E. Loth

Abstract Various types of micro-vortex generators (μVGs) are investigated for control of a supersonic turbulent boundary layer subject to an oblique shock impingement, which causes flow separation. The micro-vortex generators are embedded in the boundary layer to avoid excessive wave drag while still creating strong streamwise vortices to energise the boundary layer. Several different types of µVGs were considered including micro-ramps and micro-vanes. These were investigated computationally in a supersonic boundary layer at Mach 3 using monotone integrated large eddy simulations (MILES). The results showed that vortices generated from μVGs can partially eliminate shock induced flow separation and can continue to entrain high momentum flux for boundary-layer recovery downstream. The micro-ramps resulted in thinner downstream displacement thickness in comparison to the micro-vanes. However, the strength of the streamwise vorticity for the micro-ramps decayed faster due to dissipation especially after the shock interaction. In addition, the close spanwise distance between each vortex for the ramp geometry causes the vortex cores to move upwards from the wall due to induced upwash effects. Micro-vanes, on the other hand, yielded an increased spanwise spacing of the streamwise vortices at the point of formation. This resulted in streamwise vortices staying closer to the floor with less circulation decay, and the reduction in overall flow separation is attributed to these effects. Two hybrid concepts, named ‘thick-vane’ and ‘split-ramp’, were also studied where the former is a vane with side supports and the latter has a uniform spacing along the centreline of the baseline ramp. These geometries behaved similar to the micro-vanes in terms of the streamwise vorticity and the ability to reduce flow separation, but are more physically robust than the thin vanes.


Author(s):  
Vivek V. Kumar ◽  
Surendra Bogadi

In the present study computational tests were carried out to get an understanding of the flow field in a pure mixedcompression hypersonic inlet at a free stream Mach number of 7 and an altitude of 35km. Structured meshes have been used for depicting the motion of fluid inside the inlet. First, a grid has been selected after conducting a grid study. Two dimensional simulations were carried out with standard sst k-ω model using FLUENT. Computational results are compared with the available data. The results obtained from the computational tests revealed several important flow field details at hypersonic speeds. The basic shock structure inside the inlet was obtained. The boundary layer formed inner side of the engine had an adverse pressure gradient on the top ramp. Due to this the boundary layer thickens and the static pressure starts to decrease whose effect leads till the trailing edge of inlet. By providing small wedge shaped Micro-Vortex Generator (MVG) where the shockboundary layer occurs we can smooth the boundary layer formed inside the inlet. Thus there will be more efficient compression than the actual case. The results obtained in the present series of tests, could help the hypersonic inlet design optimization at offdesign condition


Author(s):  
Shan Ma ◽  
Wuli Chu ◽  
Xiaolin Sun ◽  
Zhengtao Guo ◽  
Song Yan

The axial location of full-span boundary layer suction is studied to explore the influences of suction slot on the cascade performance. At the design condition, the slot with 50% axial location shows a superior capability to reduce the total pressure loss. At the near stall condition, the more upstream of the suction slot is moved, the more total pressure loss is reduced, and the suction slot with a location of 0.7 axial chord length cannot effectively reduces the total pressure loss in all conditions. Moreover, a rearranged segmented suction slot according to the distribution characteristics of the flow reversal region is developed and compared with full-span boundary layer suction. The segmented suction slot shows significant advantages in delaying the stall occurrence, and the stall point is delayed from 7.9° to 10.0° compared with the baseline. According to a quantitative analysis method selected to measure the performances of flow control technologies, the wake loss is significantly reduced by the segmented suction slot. Finally, a set of micro-vortex generator is introduced in the cascade with a segmented suction slot, and the conclusion indicates that the portion near the end-wall is very effective to reduce the flow loss.