Effect of doxycycline doped Bio-oss® on vertical bone augmentation on rat calvaria

Author(s):  
Zhang Peng
2014 ◽  
Vol 56 (1) ◽  
pp. 23-28 ◽  
Author(s):  
Noriko Tsuchiya ◽  
Shuichi Sato ◽  
Risa Kigami ◽  
Eisuke Kawano ◽  
Masatoshi Takane ◽  
...  

Author(s):  
H Shino ◽  
A Hasuike ◽  
Y Arai ◽  
M Honda ◽  
K Isokawa ◽  
...  

2019 ◽  
Vol 38 (2) ◽  
pp. 211-217
Author(s):  
Peng ZHANG ◽  
Lin DING ◽  
Shohei KASUGAI

2021 ◽  
Vol 11 (12) ◽  
pp. 5622
Author(s):  
Nicola De Angelis ◽  
Luca Solimei ◽  
Claudio Pasquale ◽  
Lorenzo Alvito ◽  
Alberto Lagazzo ◽  
...  

Bone augmentation procedures represent a real clinical challenge. One option is the use of titanium meshes. Additive manufacturing techniques can provide custom-made devices in titanium alloy. The purpose of this study was to investigate the material used, which can influence the outcomes of the bone augmentation procedure. Specific test samples were obtained from two different manufacturers with two different shapes: surfaces without perforations and with calibrated perforations. Three-point bending tests were run as well as internal friction tests to verify the Young’s modulus. Test samples were placed in two different buffered solutions and analyzed with optical microscopy. A further SEM analysis was done to observe any microstructural modification. Three-point flexural tests were conducted on 12 specimens. Initial bending was observed at lower applied stresses for the perforated samples (503 MPa) compared to non-perforated ones (900 MPa); the ultimate flexural strength was registered at 513 MPa and 1145 MPa for perforated and non-perforated samples, respectively. Both microscopic analyses (optical and SEM) showed no significant alterations. Conclusions: A normal masticatory load cannot modify the device. Chemical action in the case of exposure does not create macroscopic and microscopic alterations of the surface.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yong Yang ◽  
Huiting Hu ◽  
Mianyan Zeng ◽  
Hongxing Chu ◽  
Zekun Gan ◽  
...  

Abstract Background Few large-sample studies in China have focused on the early survival of dental implants. The present study aimed to report the early survival rates of implants and determine the related influencing factors. Methods All patients receiving dental implants at our institution between 2006 and 2017 were included. The endpoint of the study was early survival rates of implants, according to gender, age, maxilla/mandible, dental position, bone augmentation, bone augmentation category, immediate implant, submerged implant category, implant diameter, implant length, implant torque, and other related factors. Initially, SPSS22.0 was used for statistical analysis. The Chi-square test was used to screen all factors, and those with p < 0.05 were further introduced into a multiple logistic regression model to illustrate the risk factors for early survival rates of implants. Results In this study, we included 1078 cases (601 males and 477 females) with 2053 implants. After implantation, 1974 implants were retained, and the early survival rate was 96.15%. Patients aged 30–60 years (OR  2.392), with Class I bone quality (OR  3.689), bone augmentation (OR  1.742), immediate implantation (OR  3.509), and implant length < 10 mm (OR  2.972), were said to possess risk factors conducive to early survival rates. Conclusions The early survival rate of implants in our cohort exceeded 96%, with risk factors including age, tooth position, bone quality, implant length, bone augmentation surgery, and immediate implantation. When the above factors coexist, implant placement should be treated carefully.


Sign in / Sign up

Export Citation Format

Share Document