scholarly journals FLEXURAL TESTING OF WOOD-CONCRETE COMPOSITE BEAM MADE FROM KAMPER AND BANGKIRAI WOOD

2015 ◽  
Vol 2 (2) ◽  
Author(s):  
Fengky Satria Yoresta

Certain wood has a tensile strength that almost equal with steel rebar in reinforced concrete beams. This research aims to understand the capacity and flexural behavior of concrete beams reinforced by wood (wood-concrete composite beam). Two different types of beams based on placement positions of wood layers are proposed in this study. Two kinds of wood used are consisted of Bangkirai (Shorea laevifolia) and Kamper (Cinnamomum camphora), meanwhile the concrete mix ratio for all beams is 1 cement : 2 fine aggregates : 3 coarse aggregates. Bending test is conducted by using one-point loading method. The results show that composite beam using Bangkirai wood is stronger than beams using Kamper wood. More thicker wood layer in tensile area will increase the flexural strength of beams. Crack patterns identified could be classified into flexural cracks, shear cracks, and split on wood layer Beberapa jenis kayu tertentu memiliki kekuatan tarik yang hampir sama dengan tulangan baja pada balok beton bertulang. Penelitian ini bertujuan memahami kapasitas dan perilaku lentur balok beton bertulang yang diperkuat menggunakan kayu (balok komposit beton-kayu). Dua tipe balok yang berbeda berdasarkan posisi penempatan kayu digunakan dalam penelitian ini. Dua jenis kayu yang digunakan adalah kayu Bangkirai (Shorea laevifolia) and Kamper (Cinnamomum camphora), sementara itu rasio campuran beton untuk semua balok menggunakan perbandingan 1 semen : 2 agregat halus : 3 agregat kasar. Pengujian lentur dilakukan menggunakan metode one-point loading. Hasil penelitian menunjukkan bahwa balok komposit dengan kayu Bangkirai lebih kuat dibandingkan balok dengan kayu Kamper. Semakin tebal lapisan kayu yang berada di daerah tarik akan meningkatkan kekuatan lentur balok. Pola kerusakan yang teridentifikasi dapat diklasifikasikan menjadi retak lentur, retak geser, dan pecah pada kayu

Author(s):  
Rendy Thamrin ◽  
Zaidir Zaidir ◽  
Devitasari Iwanda

An experimental study was carried out to evaluate the ductility of reinforced concrete beams longitudinally reinforced with hybrid FRP-Steel bars. The specimens were fourteen reinforced concrete beams with and without hybrid reinforcement. The test variables were bars position, the ratio of longitudinal reinforcement, and the type of FRP bars. The beams were loaded up to failure using a four-point bending test. The performance of the tested beams was observed using the load-deflection curve obtained from the test. Numerical analysis using the fiber element model was used to examine the growth of neutral axis depth due to the effect of test variables. The neutral axis curves were then used to further estimate the neutral axis angle and neutral axis displacement index. The test results show that the position of the reinforcement greatly influences the flexural behavior of the beam with hybrid reinforcement. It was observed from the test that the flexural capacity of beams with hybrid reinforcement is 4% to 50% higher than that of the beams with conventional steel bars depending on bars position and the ratio of longitudinal reinforcement. The ductility decreases as the hybrid reinforcement ratio (Af/As) increases. This study also showed that a numerical model developed can predict the flexural behavior of beams with hybrid reinforcement with reasonable accuracy.


2013 ◽  
Vol 319 ◽  
pp. 440-443
Author(s):  
Seung Hun Kim ◽  
Yong Taeg Lee ◽  
Tae Soo Kim ◽  
Seong Uk Hong

This study evaluates the flexural performance of reinforced concrete beams with GFRP(Glass Fiber Reinforced Polymer) bars and RCA(Recycled Coarse Aggregates). A total of four specimens with various replacement ratios of RCA (0%, 30%, 50%, and 100%) were tested. An investigation was performed on the influence of RCA with various replacement ratios on load-carrying capacity, post cracking stiffness, cracking pattern, and ductility. The test results showed that replacement ratios of RCA had not a bad effect on concrete compressive strength or flexural strength of beams. They were compared with the design flexural strength and the nominal moment predictions of ACI Code.


2020 ◽  
Vol 10 (2) ◽  
pp. 5352-5360
Author(s):  
F. El Ame ◽  
J. N. Mwero ◽  
C. K. Kabubo

Transverse openings are often provided to reinforced concrete beams to accommodate utility ducts and pipes. This technique is usually adopted to avoid the creation of dead space in structures caused by extended dropped ceilings and leads to significant cost saving. On the other hand, the provision of openings through a beam creates a reduction in its strength and affects serviceability. In this study, ten reinforced concrete beams were cast using C30 concrete. Material characterization and engineering properties tests were carried out to ensure compliance with the requirements provided by the codes of practice. The effect of vertical positioning and size of openings was investigated through subjecting the beams to a four-point bending test after 28 days of curing. Maximum load capacity, first cracking load, and deflections at mid-span were recorded and crack pattern and failure mode were evaluated. Test data showed that openings of depth greater than 0.4d significantly affect the beams’ strength and lead to earlier cracking, while the failure mode remains essentially the same, a diagonal tension crack through the opening except for opening of 0.5d size where the failure occurred by a sudden formation of two independent shear cracks above and below the opening. When holes were located above the centroid of the section, the beams exhibited a lesser deflection characterized by the absence of plastic deformation. Furthermore, a significant reduction in strength was recorded compared to cases where the positioning of openings was in tension chords. This was validated using equations from the ACI code of reinforced concrete design.


2019 ◽  
Vol 5 (7) ◽  
pp. 1533-1542 ◽  
Author(s):  
Abdul Hafeez Buller ◽  
Bashir Ahmed Memon ◽  
Mahboob Oad

Fire being one of the hazards causes external and internal adverse effects on concrete. On the other hand, demolishing waste causes numerous environmental issues due to lack of proper disposal management. Therefore, this research work presents experimental evaluation of effect of 12-hur fire on flexural behavior of reinforced concrete beams made with partial replacement of natural coarse aggregates with coarse aggregates from demolished concrete. The model beams are prepared using both normal and rich mix. Natural coarse aggregates are replaced in 50% dosage. Also, the beams without recyclable aggregates are prepared to check the results of proposed beams. After 28-day curing all the beams are exposed to fire for 12-hour at 1000°C in purpose made oven, followed by testing in universal load testing machine under central point load. During the testing deflection, load, and cracks are monitored. Analysis of flexural behavior and cracking reveals that after 12-hour fire residual strength of the beams is 52%. This shows loss of the strength of reinforced concrete beams thus requires appropriate retrofitting decision before putting again the structure in service after fire. Observation of cracks shows that most of the beams failed in shear with minor flexural cracks. In comparison to the results of control specimen the proposed beams show good fire resistance. The outcome of the research will prove landmark for future scholars and help the industry personals in understanding the behavior of the material in fire.


2015 ◽  
Vol 752-753 ◽  
pp. 668-673
Author(s):  
Rita Irmawaty ◽  
Rudy Djamaluddin ◽  
Robby Kwandou

An experimental investigation on laboratory simulation of reinforced concrete beams submerged in sea water was carried out. The research aimed to analyze the beam flexural behavior cause by submersion effect in the marine environment and simulation pool. Flexural testing was conducted by using two point loading up to beams ruptured. Total 18 reinforced concrete beams of 10 cm x 12 cm x 60 cm in dimension with GFRP-S bonded on the bottom side. Nine beams were submerged in the marine environment and 9 beams were submerged in the simulation pool. Exposure period is 1, 3 and 6 months after 28 days cured in fresh water. The result indicate that the ultimate load and bonding capacity of beam specimens submersed in the marine environment were relatively lower than the specimens submersed in simulation pool. Based on this experimental study, submerging of specimens in simulation pool (Pp ) could be used to predict specimens submersed in marine (Ps) by using equation


Sign in / Sign up

Export Citation Format

Share Document