AIR QUALITY ANALYSIS SYSTEM FOR INDOOR ENVIRONMENT AND AUTOMATION USING IoT

Author(s):  
SUDHAN N. MADHU ◽  
MAHADEVASWAMY U. B. ◽  
◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Bo Lu ◽  
Weijie Zhu ◽  
Yu Fan ◽  
Dong Shi ◽  
Liwei Ma

Abstract Background A prospective cohort study was performed to evaluate whether the Optical Quality Analysis System (OQAS) can serve as a valuable additional indicator for appropriate posterior capsulotomy referral. Methods One hundred and five eyes from 96 patients undergoing capsulotomy were divided into precapsulotomy logMAR CDVA ≤0.1 group and logMAR CDVA > 0.1 group. CDVA, and the Visual Function 14 index (VF-14) score were estimated before and 1 month after capsulotomy. The objective scattering index (OSI) value was measured by using the OQAS. Posterior capsule opacification (PCO) severity was assessed with Evaluation of PCO 2000 (EPCO 2000) software. Results In logMAR CDVA > 0.1 group, the correlations of OSI, logMAR CDVA, EPCO score and VF-14 score were very strong preoperatively. In logMAR CDVA ≤0.1 group, preoperatively, OSI was correlated with logMAR CDVA (r = 0.451), EPCO score (r = 0.789), and VF-14 score (r = 0.852). LogMAR CDVA has weak correlation with VF-14 score (r = − 0.384) and EPCO score (r = 0.566). VF-14 score was correlated with EPCO score (r = − 0.669). In the logMAR CDVA ≤0.1 group, there was no significant difference in logMAR CDVA between precapsulotomy and postcapsulotomy (P > 0.05). In the two groups, all the other optical quality parameters were significantly improved after capsulotomy (P < 0.05). In logMAR CDVA > 0.1 group, the area under the curve of the ROC of the OSI was 0.996 (P = 0.000). In logMAR CDVA ≤0.1 group, the area under the curve of the ROC of the OSI was 0.943 (P = 0.000). Conclusions The OSI was useful for evaluating of PCO and prediction of beneficial capsulotomy. Especially for patients with slight PCO and better visual acuity, OSI is more valuable than CDVA and completely objective examination. Trial registration The study protocol was registered at the Chinese Clinical Trial Registry. Register: ChiCTR1800018842 (Registered Date: October 13th, 2018).


Author(s):  
Laurentiu Predescu ◽  
Daniel Dunea

Optical monitors have proven their versatility into the studies of air quality in the workplace and indoor environments. The current study aimed to perform a screening of the indoor environment regarding the presence of various fractions of particulate matter (PM) and the specific thermal microclimate in a classroom occupied with students in March 2019 (before COVID-19 pandemic) and in March 2021 (during pandemic) at Valahia University Campus, Targoviste, Romania. The objectives were to assess the potential exposure of students and academic personnel to PM and to observe the performances of various sensors and monitors (particle counter, PM monitors, and indoor microclimate sensors). PM1 ranged between 29 and 41 μg m−3 and PM10 ranged between 30 and 42 μg m−3. It was observed that the particles belonged mostly to fine and submicrometric fractions in acceptable thermal environments according to the PPD and PMV indices. The particle counter recorded preponderantly 0.3, 0.5, and 1.0 micron categories. The average acute dose rate was estimated as 6.58 × 10−4 mg/kg-day (CV = 14.3%) for the 20–40 years range. Wearing masks may influence the indoor microclimate and PM levels but additional experiments should be performed at a finer scale.


2021 ◽  
Vol 1964 (4) ◽  
pp. 042078
Author(s):  
N Revathi ◽  
P Sengottuvelan ◽  
J Thimmia Raja

Author(s):  
Seyed Ali Keshavarz ◽  
Mazyar Salmanzadeh ◽  
Goodarz Ahmadi

Recently, attention has been given to indoor air quality due to its serious health concerns. Clearly the dispersion of pollutant is directly affected by the airflow patterns. The airflow in indoor environment is the results of a combination of several factors. In the present study, the effects of thermal plume and respiration on the indoor air quality in a ventilated cubicle were investigated using an unsteady computational modeling approach. The person-to-person contaminant transports in a ventilated room with mixing and displacement ventilation systems were studied. The effects of rotational motion of the heated manikins were also analyzed. Simulation results showed that in the cases which rotational motion was included, the human thermal plume and associated particle transport were significantly distorted. The distortion was more noticeable for the displacement ventilation system. Also it was found that the displacement ventilation system lowered the risk of person-to-person transmission in an office space in comparison with the mixing ventilation system. On the other hand the mixing system was shown to be more effective compared to the displacement ventilation in removing the particles and pollutant that entered the room through the inlet air diffuser.


Author(s):  
Eli G. Pale-Ramon ◽  
Luis J. Morales-Mendoza ◽  
Sonia L. Mestizo-Gutierrez ◽  
Mario Gonzalez-Leee ◽  
Rene F. Vazquez-Bautista ◽  
...  

2012 ◽  
Vol 236-237 ◽  
pp. 839-843
Author(s):  
Xiao Meng Cui ◽  
Guang Xue Chen ◽  
Huan Mei Wang ◽  
Lin Lin Chen

In this study we present a new framework to assess line micro quality of multicolor prints adapted to a low-cost image quality analysis system based on common flatbed scanner. The contribution elements including quality metrics, measurement principle, applying methods and detection instrument, which were complemented and sorted in terms of ISO 13660 standard, were described and a case experiment was conducted to survey the output performance of both inkjet printer and xerographic printer, two most popular digital printing technologies. Their qualities were compared in details rendering angle such as width and straightness of line, raggedness and blurriness in line edges, as well as darkness and contrast in color. The results verify the efficiency and shortcomings of the framework. Meanwhile, the metric values let us take an investigation in the character of each digital printing technology in micron size.


Sign in / Sign up

Export Citation Format

Share Document